Regency P121/P131-NG2, P121/P131-LP2 dimensions Option + H1 + H2

Page 7

Gas Fireplaces

Horizontal Venting with Two (2) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V

H+ H1

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

1’ Min.

2’ Max.

37 feet.

 

 

 

B)

2’ Min.

5’ Max.

Total horizontal sections must

 

 

 

not exceed 15 feet.

C)

3’ Min.

8’ Max.

Minimum of 1 foot between

 

 

 

D)

4’ Min.

11’ Max.

90° elbows is required.

E)

5’ Min.

14’ Max.

 

 

 

 

 

F)

6’ Min.

15’ Max.

 

Horizontal Venting with Two (2) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

1’ Max.

1’ Min.

3’ Max.

37 feet.

 

 

 

 

B)

3’ Max.

2’ Min.

6’ Max.

Total horizontal sections must

 

 

 

 

not exceed 12 feet.

C)

5’ Max.

3’ Min.

9’ Max.

Minimum of 1 foot between

D)

8’ Max.

5’ Min.

12’ Max.

90° elbows is required.

 

 

 

 

 

June 2007 Regency Product Specifications Book

P121-P131 Gas Fireplace

Horizontal Venting with Three (3) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H + H1

Maximum total pipe: length,

 

 

 

of all sections, must not

A)

2’ Min.

3’ Max.

exceed 37 feet.

 

 

 

B)

3’ Min.

6’ Max.

Total horizontal sections

 

 

 

must not exceed 12 feet.

C)

4’ Min.

9’ Max.

Minimum of 1 foot between

 

 

 

D)

5’ Min.

12’ Max.

90° elbows is required.

Horizontal Venting with Three (3) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H

V

H + H1 + H2

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

1’ Max.

2’ Min.

3’ Max.

37 feet.

 

 

 

 

Total horizontal sections must

B)

3’ Max.

3’ Min.

6’ Max.

not exceed 12 feet.

 

 

 

 

Minimum of 1 foot between

C)

5’ Max.

4’ Min.

9’ Max.

90° elbows is required.

 

 

 

 

 

 

 

 

 

F)

7’ Max.

5’ Min.

12’ Max.

 

 

 

 

 

 

75

Gas Fireplaces

Image 7
Contents June 2007 Regency Product Specifications Book Model P121/P131-NG2 P121/P131-LP2Approved Venting Systems Combustible Mantels Framing and FinishingClearance Requirements Parallel Wall ClearancesHorizontal Terminations Only Below Grade Snorkel Installation Dura-Vent OnlyRegency Direct Vent System Flex Snorkel TerminationsHorizontal or Vertical Terminations Rigid Pipe VentingVenting Arrangements Vertical Terminations Vertical Venting with One 1 90 ElbowOption + H1 Horizontal Venting with One 1 90 Elbow Venting Arrangements Horizontal TerminationsOption + H1 + H2