Regency dimensions Model P121/P131-NG2 P121/P131-LP2, Approved Venting Systems

Page 1

Gas Fireplaces

P121-P131 Gas Fireplace

P121 - P121LC/RC - P131 Zero Clearance Direct Vent Gas Fireplace

Model

P121/P131-NG2

 

P121/P131-LP2

Fuel Type

Natural Gas

 

Propane

 

 

 

 

 

Minimum Supply Pressure

5” W.C. (1.25 kPa)

 

12” W.C. (3.00 kPa)

 

 

 

 

 

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

 

11” W.C. (2.74 kPa)

 

 

 

 

 

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

 

2.9” W.C. (0.72 kPa)

 

 

 

 

 

Orifi ce Size

#31 DMS

 

#50 DMS

 

 

 

 

 

Minimum Input

20,500 BTU/h (6.01 kW)

 

20,600 BTU/h (6.04 kW)

 

 

 

 

 

Maximum Input

40,000 BTU/h (11.72 kW)

 

39,000 BTU/h (11.43 kW)

 

 

 

 

 

Vent Sizing

4” Inner / 6-5/8” Outer

 

4” Inner / 6-5/8” Outer

 

 

 

 

 

 

 

 

 

 

Approved Venting Systems

 

Flex Vent Systems:

FPI AstroCap™ Flex Vent

 

 

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS

 

 

American Metal Products Ameri Vent

 

 

Security Secure Vent®

 

 

Selkirk Direct-Temp.

M

 

O

 

 

 

P121 See Thru

P131 Pier

N

 

P

 

Electrical

BACK

Gas Line

 

Inlet

Inlet

 

 

 

P121RC Right Corner

P121LC Left Corner

B

G

 

F

 

 

 

C

D

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Dimensions

Description

 

 

P121

 

P121LC/RC

P131

 

 

 

 

 

 

 

 

 

 

 

 

A

Front Face Width

 

 

43-1/2”

 

 

41-1/2”

41-1/2”

 

 

(1105mm)

 

 

(1054mm)

(1054mm)

 

 

 

 

 

 

 

 

B

Total Firebox Width

 

 

46-1/4”

 

 

44-1/2”

44-1/2”

 

 

(1175mm)

 

 

(1130mm)

(1130mm)

 

 

 

 

 

 

 

 

C

Front Face Height

 

 

36” (914mm)

 

36” (914mm)

36” (914mm)

D

Height w/ Standoff

 

42” (1067mm)

 

42” (1067mm)

42” (1067mm)

E

Unit Depth

 

 

25” (635mm)

 

 

26-13/16”

25” (635mm)

 

 

 

 

(681mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

F

Top Offset Depth

 

 

21-1/8”

 

 

21-1/8”

21-1/8”

 

 

(537mm)

 

 

(537mm)

(537mm)

 

 

 

 

 

 

 

 

G

Inset to Standoff

 

 

4-3/4”

 

 

4-3/4”

3” (76mm)

 

 

(121mm)

 

 

(121mm)

 

 

 

 

 

 

 

 

 

 

 

If the provided 3” extension trim is not installed the P121(LC/RC)/ P131 must be installed with non-combustible facing up to 8” above the fi replace. Otherwise combustible facing may be used above the extension trim.

Please refer to Page 11 (Exterior Vent Terminations)

for additional guidelines on vent locations.

June 2007 Regency Product Specifications Book

Greyed out framing will not apply to all units.

Please refer to the manual.

L

I

H

J 8”

Non-Combustible

Top of

Unit

Material *

 

Combustible

 

 

Material

 

K

3”

Extension

 

 

Trim

Framing Dimensions

Description

P121

 

P121LC/RC

 

P131

 

 

 

 

 

 

 

H

Framing Width

46-3/4”

 

45”

 

45”

(1187mm)

 

(1143mm)**

 

(1143mm)**

 

 

 

 

I**

Framing Height **

42-1/2”

 

42-1/2”

 

42-1/2”

(1080mm)

 

(1080mm)

 

(1080mm)

 

 

 

 

J**

Framing Depth**

25” (635mm)**

 

26-13/16”

 

25” (635mm)**

 

(681mm)

 

 

 

 

 

 

 

K

Vent Centerline Height

 

42-13/16” (1072mm)

 

L

Framed Chase Ceiling

 

 

48-1/4” (1226mm)

 

M

Electrical Inlet Height

2” (51mm)

 

2” (51mm)

 

2” (51mm)

 

 

N

Electrical Inlet Inset

11-3/8”

 

13-5/16”

 

11-3/8”

(289mm)

 

(338mm)

 

(289mm)

 

 

 

 

O

Gas Connection Height

1-11/16”

 

1-11/16”

 

1-5/8” (41mm)

(43mm)

 

(43mm)

 

 

 

 

 

 

P

Gas Connection Inset

11-1/2”

 

11-1/2”

 

11-1/2”

(292mm)

 

(292mm)

 

(292mm)

 

 

 

 

 

 

 

 

 

 

 

**Refer to the manual for variations effected by fi nishing material thickness.

69

Gas Fireplaces

Image 1
Contents June 2007 Regency Product Specifications Book Model P121/P131-NG2 P121/P131-LP2Approved Venting Systems Clearance Requirements Framing and FinishingParallel Wall Clearances Combustible MantelsRegency Direct Vent System Flex Below Grade Snorkel Installation Dura-Vent OnlySnorkel Terminations Horizontal Terminations OnlyVenting Arrangements Vertical Terminations Rigid Pipe VentingVertical Venting with One 1 90 Elbow Horizontal or Vertical TerminationsOption + H1 Horizontal Venting with One 1 90 Elbow Venting Arrangements Horizontal TerminationsOption + H1 + H2