Regency P121/P131-NG2, P121/P131-LP2 dimensions Option + H1

Page 5

Gas Fireplaces

Vertical Venting with Two (2) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

1’ Min.

4’ Max.

37 feet.

 

 

 

B)

2’ Min.

6’ Max.

Total horizontal sections must

 

 

 

not exceed 17 feet.

C)

3’ Min.

9’ Max.

Minimum of 1 foot between

 

 

 

D)

4’ Min.

12’ Max.

90° elbows is required.

E)

5’ Min.

15’ Max.

 

 

 

 

 

E)

6’ Min.

17’ Max.

 

Vertical Venting with Two (2) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

H + H1

V

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

2’ Max.

1’ Min.

37 feet.

 

 

 

B)

4’ Max.

2’ Min.

Total horizontal sections must

 

 

 

not exceed 8 feet.

C)

6’ Max.

3’ Min.

Minimum of 1 foot between

 

 

 

D)

8’ Max.

4’ Min.

90° elbows is required.

 

 

 

 

June 2007 Regency Product Specifications Book

P121-P131 Gas Fireplace

Vertical Venting with Three (3) 90° Elbows - Initial vertical section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H + H1

Maximum total pipe: length, of

 

 

 

all sections, must not exceed

A)

2’ Min.

3’ Max.

37 feet.

 

 

 

B)

3’ Min.

6’ Max.

Total horizontal sections must not

 

 

 

exceed 12 feet.

C)

4’ Min.

9’ Max.

Minimum of 1 foot between 90°

 

 

 

D)

5’ Min.

12’ Max.

elbows is required.

Vertical Venting with Three (3) 90° Elbows - Initial horizontal section.

Two 45° elbows = One 90° elbow

Option

V+ V1

H

H + H1

Maximum total pipe: length, of

 

 

 

 

all sections, must not exceed

A)

2’ Min.

1’ Max.

2’ Max.

37 feet.

 

 

 

 

Total horizontal sections must

B)

3’ Min.

4’ Max.

5’ Max.

not exceed 12 feet.

 

 

 

 

Minimum of 1 foot between 90°

C)

4’ Min.

6’ Max.

8’ Max.

elbows is required.

 

 

 

 

D)

5’ Min.

8’ Max.

12’ Max.

 

 

 

 

 

 

73

Gas Fireplaces

Image 5
Contents Approved Venting Systems Model P121/P131-NG2 P121/P131-LP2June 2007 Regency Product Specifications Book Clearance Requirements Framing and FinishingParallel Wall Clearances Combustible MantelsRegency Direct Vent System Flex Below Grade Snorkel Installation Dura-Vent OnlySnorkel Terminations Horizontal Terminations OnlyVenting Arrangements Vertical Terminations Rigid Pipe VentingVertical Venting with One 1 90 Elbow Horizontal or Vertical TerminationsOption + H1 Horizontal Venting with One 1 90 Elbow Venting Arrangements Horizontal TerminationsOption + H1 + H2