Regency E21-LP2 Installation, Important Message Save These Instructions, Before YOU Start

Page 6

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The Regency® Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual fi rst. Consult the "authority having jurisdiction" to determine the need for a permit prior to start- ing the installation. It is the responsibility of the installer to ensure this fi replace is installed in compliance with the manufacturer's instructions and all applicable codes.

BEFORE YOU START

Safe installation and operation of this appli- ance requires common sense, however, we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following:

INSTALLATION AND REPAIR SHOULD BE DONE BY A QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON. MORE FREQUENT CLEANING MAY BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING,BEDDINGMATERIAL, ETC. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS AND CIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

WARNING: FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILLVOIDYOURWARRANTYAND MAY CAUSE A SERIOUS HOUSE FIRE.

CHILDRENANDADULTSSHOULD BEALERTEDTOTHEHAZARDSOF HIGHSURFACETEMPERATURES, ESPECIALLY THE FIREPLACE GLASS,ANDSHOULDSTAYAWAY TO AVOID BURNS OR CLOTHING IGNITION.

YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISEDWHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

C L O T H I N G O R O T H E R FLAMMABLEMATERIALSHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

GENERAL SAFETY

INFORMATION

1)The appliance installation must conform with local codes or, in the absence of local codes,withthecurrentCanadian or National Gas Codes, CAN1-B149 or ANSI Z223.1 Installation Codes.

2)The appliance when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes with the current National Electrical Code, ANSI/NFPA 70 or CSA C22.1 Canadian Electrical Code.

3)See general construction and assembly instructions. The appliance and vent should be enclosed.

4)This appliance must be connected to the specifi ed vent and termination cap to the outside of the building envelope. Never vent to another room or inside a building. Make sure that the vent is installed as per Venting instructions.

5)This appliance may only be installed in a vented, solid fuel burning masonry, listed factory built fi replace, or zero clearance kit part # 530-936.

6)This appliance is Listed for bedroom installations when used with a Listed Millivolt Thermostat. Some areas may have further requirements, check local codes before installation.

7)This appliance is Listed for Alcove installations, maintain minimum Alcove clearances as follows, minimum ceiling height of 53-1/2", minimum width of 48" and a maximum depth of 36".

8)This unit is not approved for installation into a mobile home.

9)Inspect the venting system annually for blockage and any signs of deterioration.

10)Any safety glass removed for servicing must be replaced prior to operating the appliance.

11)To prevent injury, do not allow anyone who is unfamiliar with the operation to use the fi replace insert.

12)Wearglovesandsafetyglassesforprotection while doing required maintenance.

13)Ensureadequatecombustionandventilation air.

14)Under no circumstances should this appliance be modifi ed. Parts that have to be removed for servicing should be replaced prior to operating this appliance.

15)Installation and any repairs to this appliance should be done by a qualified service person. A professional service person should be called to inspect this appliance annually. Make it a practice to have all of your gas appliances checked annually.

16)Do not slam shut or strike the glass door.

17)Under no circumstances should any solid fuels (wood, paper, cardboard, coal, etc.) be used in this appliance.

18)The appliance area must be kept clear and free of combustible materials, (gases and other fl ammable vapours and liquids).

19)Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the electrical control system and any gas control which has been under water.

20)WARNING: Failure to position the parts in accordance with the diagrams in this manual or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

21)WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system or tampering with the blocked vent shut-off system can result in carbon monoxide (CO) poisoning and possible death.

Emissions from burning wood or gas could contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

6

Regency® E21-2 Gas Fireplace Insert

Image 6
Contents E21 Gas Insert Congratulations Table of Contents Safety Label Duplicate Serial NoRequirements MA Code CO DetectorImportant Message Save These Instructions InstallationGeneral Safety Information Before YOU StartInstallation Checklist Minimum Fireplace ClearancesPolicy for Solid Fuel Burning & Factory Built Fireplaces Clearances to Combustibles Combustible boardGAS Connection High ElevationWiring Diagrams Lug DetailFlue Connector Installation For Propane Units and Units Equipped with DC Spark BoxesVenting GAS Pipe Pressure TestingOffset Flue Adaptor Combustion and Ventilation AIRTest for Flue Spillage Valve DescriptionGAS Insert Aerationsystem Optional Brick PanelLOG SET Installation Faceplate & Trim InstallationFlush Glass Use of substitute glass will Void all product warrantiesFlush Louvers Optional BAY Front BAY LouversConversion Kit# 534-969 from NG to LP Installation of the DC Sparker Chain Full Screen Doors Hinge Remote Control Wall Switch Wall ThermostatOperating Instructions Copy of Lighting Plate Instructions Maintenance Disconnect the power Door Glass ReplacementRemoving Valve Assembly Removing the FANParts List DescriptionBurner Assembly & LOG SET Bay Door Flush Door DescriptionFaceplate Assembly Warranty ConditionsInstaller Please complete the following information

E21-NG2, E21-LP2 specifications

The Regency E21-LP2 and E21-NG2 are modern gas fireplaces that embody style, efficiency, and advanced engineering, making them standout choices for homeowners seeking both aesthetic appeal and functional utility. These models are designed to complement a wide variety of interior decor styles while providing warmth and comfort.

One of the most prominent features of the E21 series is its high-efficiency heating capability, which allows these fireplaces to generate a significant amount of heat while using minimal fuel. The E21-LP2, designed for liquid propane, and the E21-NG2, designed for natural gas, ensure versatile installation options for different home setups. Homeowners can select the fuel type that best suits their needs or local availability.

The design of the Regency E21 models is marked by a large viewing area, providing an unobstructed view of the mesmerizing flames. The impressive flame pattern not only adds to the ambiance but also creates a warm and inviting focal point in any living space. The elegant, clean lines and contemporary frame enhance the fireplace's visual appeal, making it an excellent choice for modern interiors.

In terms of technology, both models are equipped with the advanced IntelliFire ignition system, which offers reliability and ease of use. This system ensures that igniting the fireplace is straightforward and safe, freeing homeowners from the hassles of traditional methods. Furthermore, the built-in programmable thermostat allows for precise temperature control, ensuring optimal comfort levels with minimal environmental impact.

Moreover, the Regency E21 series is constructed with high-quality materials designed to offer durability and longevity. The fireplaces come with a variety of finish options, allowing homeowners to personalize their units to match their specific tastes and styles. The E21 models also feature a convenient glass safety barrier, which enhances safety while maintaining the fireplace's aesthetic appeal.

With an emphasis on energy efficiency and environmental responsibility, the E21-LP2 and E21-NG2 are not only stylish additions to any home but also economically favorable choices for homeowners. By combining practical features with contemporary design, Regency has created fireplaces that cater to modern living while providing comfort and elegance. Whether for new installations or upgrades to existing spaces, these models are sure to impress.