MAINTENANCE

6. MAINTENANCE

WARNING

Product Safety Information

Refractory Ceramic Fiber Product

This appliance contains materials made from refractory ceramic fibers (RCF). Airborne RCF, when inhaled, have been classified by the International Agency for Research on Cancer (IARC), as a possible carcinogen to humans. After the RCF materials have been exposed to temperatures above 1800°F, they can change into crystalline silica, which has been classified by the IARC as carcinogenic to humans. If particles become airborne during service or repair, inhalation of these particles may be hazardous to your health.

Avoid Breathing Fiber Particulates and Dust

Suppliers of RCF recommend the following precautions be taken when handling these materials:

Precautionary Measures: Provide adequate ventilation.

Wear a NIOSH/MSHA approved respirator.

Wear long sleeved, loose fitting clothing and gloves to prevent skin contact. Wear eye goggles.

Minimize airborne dust prior to handling and removal by water misting the material and avoiding unnecessary disturbance of materials.

Wash work clothes separately from others. Rinse washer thoroughly after use. Discard RCF materials by sealing in an airtight plastic bag.

First Aid Procedures:

Inhalation: If breathing difficulty or irritation occurs, move to a location with fresh clean air. Seek immediate medical attention if symptoms persist.

Skin Contact: Wash affected area gently with a mild soap and warm water. Seek immediate medical attention if irritation persists.

Eye Contact: Flush eyes with water for 15 minutes while holding eyelids apart. Do not rub eyes. Seek immediate medical attention if irritation persists.

Ingestion: Drink 1 to 2 glasses of water. Do not induce vomiting. Seek immediate medical attention.

17

Image 19
Contents Series EC/ECT Table of Contents Installation Clearance Using this ManualSpecial Attention Boxes Never burn garbage or paper PreinstallationClearances AIR for Combustion and VentilationPlanning the Layout Installation SurveyOld New Comments Installation Chimney / Vent and Draft ControlJacket Assembly Boiler Placement and AssemblySetting the Boiler Observation Cover Assembly Knockdown BoilersBoiler Exploded View See .1 in for parts identification Boiler Return Clearance Pressure Test Block AssemblyDo not pipe boiler before jacket is Notice installed Piping and ControlsWater Boiler Piping Water Boiler PipingHeater No Capacity Boiler Series Maximum Tankless Water Heater RatingsUse only the Hydrolevel CG450 as ControlsElectrical Burner WiringGeneral Steam Boiler with Probe Low Water Cut-Off Water Boilers Zoning with Zone Valves Check Boiler Controls Burner Setup & Boiler OperationBurner Installation Burner START-UP and AdjustmentCleaning the boiler requires the use Clean the Boiler Steam Boilers onlyModel No Shutter Pressure Head Dim. a Air Band Model NoAir Band 85 70 a DELMaintenance Monthly Maintenance with Boiler Operating Daily Maintenance with Boiler OperatingWeekly Maintenance with Boiler Operating Maintenance of Safety Relief ValveBurner mounting plate must be If a Long Shutdown is RequiredOpened to facilitate this operation Width Depth Height Boiler Dimensions & RatingsLocation Size NPT Water Steam Water Steam Output5Input Net I=B=R Ratings4EC/ECT-03 EC/ECT-04 EC/ECT-05 EC/ECT-06 Repair PartsPage Page Series EC/ECT

ECT Series, EC Series specifications

The PB Heat EC Series and ECT Series represent a significant advancement in residential and commercial heating technology, providing reliable and efficient solutions for a variety of heating applications. These series are designed to meet the needs of homeowners and businesses seeking dependable heating while also prioritizing energy efficiency and comfort.

One of the standout features of the EC Series and ECT Series is their advanced engineering, which includes a range of high-efficiency boilers. These units utilize a cast iron heat exchanger that ensures excellent thermal transfer and durability. The cast iron construction is known for its longevity, enabling these boilers to withstand high temperatures and pressures, which is essential for long-term performance and reliability.

In terms of efficiency, both series feature energy-saving technologies that comply with the latest environmental standards. The EC Series, for example, boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, indicating that a significant portion of the fuel consumed is converted into usable heat. This results in lower fuel bills and a reduced carbon footprint. The ECT Series further enhances efficiency with features like modulating burners that adjust the heat output based on demand, providing optimal comfort while minimizing energy waste.

Another notable characteristic of these series is their user-friendly controls and digital interfaces. The boilers come equipped with intuitive controls that allow homeowners to easily set and monitor their heating preferences. Many units also support advanced features, including Wi-Fi connectivity, enabling users to manage their heating systems remotely via smartphone applications.

In addition to their efficiency and user-friendly design, the PB Heat EC and ECT Series prioritize safety. These boilers incorporate multiple safety features, such as pressure relief valves and low water cut-off mechanisms, which help prevent operational hazards and ensure safe operation.

Overall, the PB Heat EC Series and ECT Series offer a robust combination of advanced heating technologies, efficiency, and safety. With their durable construction, energy-saving capabilities, and user-friendly controls, these heating solutions are ideal for those looking to invest in reliable and efficient heating systems. Whether for a residential property or a commercial facility, the EC and ECT Series stand out as exceptional choices in the modern heating landscape.