PB Heat ECT Series, EC Series manual Repair Parts, EC/ECT-03 EC/ECT-04 EC/ECT-05 EC/ECT-06

Page 24

REPAIR PARTS

8. REPAIR PARTS

Repair parts are available from your installer or by contacting PB Heat, LLC, 131 S. Church, Bally, PA 19503.

Note: Remember to include boiler model number and serial number when ordering parts.

Table 8.1

Item No.*

Description

 

 

Repair Part Stock Code

 

EC/ECT-03

 

EC/ECT-04

EC/ECT-05

 

EC/ECT-06

 

 

 

 

 

 

 

 

 

 

 

 

1

Block Assembly - EC

90662

 

90663

90239

 

90758

 

 

 

 

 

 

 

Block Assembly - ECT

90664

 

90665

90242

 

90755

 

 

 

 

 

 

 

 

 

 

 

2

Target Wall

 

50768

 

 

 

 

 

 

 

 

3

Burner Mounting Plate

 

93530

 

 

 

 

 

 

 

 

4

Observation Door

 

51677

 

 

 

 

 

 

 

 

5

5-16" - 18 x 2-1/4" Stud (use with 5/16-18 Nut)

 

[3] 51747

 

 

 

 

 

 

 

 

6

Burner Mounting Plate Internal Hinge

 

51149

 

 

 

 

 

 

 

 

 

8

High Temp. Rope 1/2" Diameter Medium Density

[48"]

 

[56"]

[64"]

 

[72"]

51211

 

51211

51211

 

51211

 

 

 

 

 

 

 

 

 

 

 

 

9

Flue Collector (EC05 & EC06 stock codes include side

90555

 

90556

99538

 

99539

cleanout plates)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

1/4"-20 x 1-3/4" Stud (use with 1/4-20 Nut)

 

[2] 51751

 

 

 

 

 

 

 

 

11

Rubber Gasket

 

51800

 

 

 

 

 

 

 

12

Cover Plate

 

99812 (includes gasket and cap screws)

 

 

 

 

 

 

 

13

Tankless Coil (Optional Water Only)

 

90534

 

 

 

 

 

 

 

 

14

3/8"-16 x 3/4" Hex Hd. Cap Screws

 

[6] 99788

 

 

 

 

 

 

 

 

15

Rubber Gasket (ECT Models)

 

90547

 

 

 

 

 

 

 

16

Cover Plate (Optional ECT Models)

 

90140 (includes gasket and cap screws)

 

 

 

 

 

 

 

17

Tankless Heater (Optional ECT Models)

 

90546

 

 

 

 

 

 

 

 

18

3/8"-16 x 3/4" Hex Hd. Cap Screws

 

[6] 99788

 

 

 

 

 

 

 

 

 

24

5/16"-18 x 1-3/4" Carriage Bolt (use with 5/16-18 Nut)

[4] 93997

 

[6] 93997

[8] 93997

 

[10] 93997

 

 

 

 

 

 

 

 

25

Side Cleanout Cover Plate

[2] 51772

 

[3] 51772

[4] 51772

 

[5] 51772

 

 

 

 

 

 

 

28

Base Liner, 1/2" x 14"

50857 (6")

 

50858 (10-1/2")

50846 (18-3/4" LG)

 

 

 

 

 

 

 

 

19

Back Jacket Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

[2] 1/4"-20 x 3/8" Truss Hd. Mach. Screw Zinc

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

Upper Left Side Jacket Panel

90278

 

90279

90280

 

90281

 

 

 

 

21A

Lower Left Side Jacket Panel

(Jacket

 

(Jacket

(Jacket

 

(Jacket

22

 

Assembly)

 

Assembly)

Assembly)

 

Assembly)

Right Side Jacket Panel

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

Front Jacket Panel

 

 

 

 

 

 

26

 

 

 

 

 

 

 

Top Jacket Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* See Figure 2.2 on page 5 for boiler exploded view.

22

Image 24
Contents Series EC/ECT Table of Contents Using this Manual Installation ClearanceSpecial Attention Boxes Preinstallation ClearancesAIR for Combustion and Ventilation Never burn garbage or paperInstallation Survey Old New Comments InstallationChimney / Vent and Draft Control Planning the LayoutBoiler Placement and Assembly Setting the BoilerObservation Cover Assembly Knockdown Boilers Jacket AssemblyBoiler Exploded View See .1 in for parts identification Pressure Test Block Assembly Do not pipe boiler before jacket is Notice installedPiping and Controls Boiler Return ClearanceWater Boiler Piping Water Boiler PipingMaximum Tankless Water Heater Ratings Heater No Capacity Boiler SeriesControls Use only the Hydrolevel CG450 asBurner Wiring ElectricalGeneral Steam Boiler with Probe Low Water Cut-Off Water Boilers Zoning with Zone Valves Burner Setup & Boiler Operation Burner InstallationBurner START-UP and Adjustment Check Boiler ControlsClean the Boiler Steam Boilers only Cleaning the boiler requires the useModel No Air Band85 70 a DEL Model No Shutter Pressure Head Dim. a Air BandMaintenance Daily Maintenance with Boiler Operating Weekly Maintenance with Boiler OperatingMaintenance of Safety Relief Valve Monthly Maintenance with Boiler OperatingIf a Long Shutdown is Required Burner mounting plate must beOpened to facilitate this operation Boiler Dimensions & Ratings Width Depth HeightLocation Size NPT Water Steam Output5 InputNet I=B=R Ratings4 Water SteamRepair Parts EC/ECT-03 EC/ECT-04 EC/ECT-05 EC/ECT-06Page Page Series EC/ECT

ECT Series, EC Series specifications

The PB Heat EC Series and ECT Series represent a significant advancement in residential and commercial heating technology, providing reliable and efficient solutions for a variety of heating applications. These series are designed to meet the needs of homeowners and businesses seeking dependable heating while also prioritizing energy efficiency and comfort.

One of the standout features of the EC Series and ECT Series is their advanced engineering, which includes a range of high-efficiency boilers. These units utilize a cast iron heat exchanger that ensures excellent thermal transfer and durability. The cast iron construction is known for its longevity, enabling these boilers to withstand high temperatures and pressures, which is essential for long-term performance and reliability.

In terms of efficiency, both series feature energy-saving technologies that comply with the latest environmental standards. The EC Series, for example, boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, indicating that a significant portion of the fuel consumed is converted into usable heat. This results in lower fuel bills and a reduced carbon footprint. The ECT Series further enhances efficiency with features like modulating burners that adjust the heat output based on demand, providing optimal comfort while minimizing energy waste.

Another notable characteristic of these series is their user-friendly controls and digital interfaces. The boilers come equipped with intuitive controls that allow homeowners to easily set and monitor their heating preferences. Many units also support advanced features, including Wi-Fi connectivity, enabling users to manage their heating systems remotely via smartphone applications.

In addition to their efficiency and user-friendly design, the PB Heat EC and ECT Series prioritize safety. These boilers incorporate multiple safety features, such as pressure relief valves and low water cut-off mechanisms, which help prevent operational hazards and ensure safe operation.

Overall, the PB Heat EC Series and ECT Series offer a robust combination of advanced heating technologies, efficiency, and safety. With their durable construction, energy-saving capabilities, and user-friendly controls, these heating solutions are ideal for those looking to invest in reliable and efficient heating systems. Whether for a residential property or a commercial facility, the EC and ECT Series stand out as exceptional choices in the modern heating landscape.