Table 5.1: Carlin Burner Specifications

CARLIN BURNER SPECIFICATIONS

Boiler

Firing Rate

Burner

 

Air

Nozzle Size

Pump

Start-up Settings

Head Bar

Model No.

Model No.

 

Shutter

Pressure

Air Band

 

 

 

 

 

 

 

 

 

 

 

 

 

EC/ECT-03-075

.75

EZ-1HP

 

Blank

0.60 70° B DEL³

150 psig

0.55

0.60 - 0.65

 

 

 

 

 

 

 

 

 

EC/ECT-03-100

1.00

EZ-1HP

 

Blank

0.85 70° A DEL

150 psig

0.65

0.85 - 1.00

 

 

 

 

 

 

 

 

 

EC/ECT-03-120

1.20

EZ-1HP

 

Blank

1.00 70° A DEL³

150 psig

0.80

0.85 - 1.00

 

 

 

 

 

 

 

 

 

Boiler

Burner

Air

 

Nozzle Size

Pump

Start-up Settings

Model No.

Model No.

Shutter

Pressure

Head Dim. A

Air Band

 

 

 

 

 

 

 

 

 

EC/ECT-04-125

99FRD

Blank

 

1.00 x 70° B DEL³

150 psig

2

40% open

 

 

 

 

 

 

 

 

EC/ECT-04-150

99FRD

Blank

 

1.25 x 60° B DEL³

150 psig

3

60% open

 

 

 

 

 

 

 

 

EC/ECT-04-175

99FRD

Blank

 

1.50 x 60° B DEL

150 psig

4

100% open

 

 

 

 

 

 

 

 

EC/ECT-05-175

99FRD

Open

 

1.50 x 60° B HAGO³

150 psig

5

10% open

 

 

 

 

 

 

 

 

EC/ECT-05-200

99FRD

Open

 

1.65 x 60° B HAGO

150 psig

5

45% open

 

 

 

 

 

 

 

 

EC/ECT-05-250

99FRD

Open

 

2.00 x 60° B HAGO³

150 psig

8

100% open

 

 

 

 

 

 

 

 

EC/ECT-06-275

102CRD

Open

 

2.25 x 60° B DEL³

150 psig

6

100% open

 

 

 

 

 

 

 

 

EC/ECT-06-300

102CRD

Open

 

2.50 x 60° B DEL

150 psig

8

100% open

 

 

 

 

 

 

 

 

 

Table 5.2: Beckett Burner Specifications

BECKETT BURNER SPECIFICATIONS (140 psig Pump Pressure)

Boiler

Burner

Burner Head

Static Plate

Nozzle Size

Start-up Settings

Head Setting

Model No.

Model No.

Air Shutter

Air Band

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EC/ECT-03-075

AFG-L1¹

L1¹

3-3/8"

0.65

60° B HAGO³

9.0

2

N/A

 

 

 

 

 

 

 

 

 

EC/ECT-03-100

AFG-L1

L1

3-3/8"

0.85

60° B HAGO

10.0

1

N/A

 

 

 

 

 

 

 

 

 

EC/ECT-03-120

AFG-L1

L1

—²

1.00

60° B HAGO³

9.0

2

N/A

 

 

 

 

 

 

 

 

EC/ECT-04-125

AFG-F6

F6

2-3/4"

1.10 80° A DEL³

5.0

1

N/A

 

 

 

 

 

 

 

 

 

EC/ECT-04-150

AFG-F6

F6

2-3/4"

1.25

80° B HAGO

8.0

1

N/A

 

 

 

 

 

 

 

 

 

EC/ECT-04-175

AFG-F6

F6

2-3/4"

1.50

80° B HAGO³

10.0

3

N/A

 

 

 

 

 

 

 

 

 

EC/ECT-05-175

AFG-MV1

M-V1-3

1.50

60° B HAGO³

10.0

3

3

 

 

 

 

 

 

 

 

 

EC/ECT-05-200

AFG-MV1

M-V1-3

1.75

60° B HAGO

10.0

9

3

 

 

 

 

 

 

 

 

 

EC/ECT-05-250

AFG-MV1

M-V1-5

2.00

45° B HAGO³

10.0

5

5

 

 

 

 

 

 

 

 

 

EC/ECT-06-275

CF-375

L1-S

2.25

45° P HAGO³

10.0

6

2

 

 

 

 

 

 

 

 

EC/ECT-06-300

CF-375

L1-S

2.50 45° P HAGO

10.0

6

3

 

 

 

 

 

 

 

 

 

Table 5.3: Riello Burner Specifications

RIELLO BURNER SPECIFICATIONS

Boiler

Firing Rate

Burner

Nozzle Size

Pump Pressure

Start-Up Settings

Model No.

Model No.

Turbulator

Air Damper

 

 

 

 

 

 

 

 

 

 

EC/ECT-03-075

.75

F5

0.60 60° B DEL³

155 psig

0.5

2.1

 

 

 

 

 

 

 

EC/ECT-03-100

1.00

F5

0.85 60° W DEL³

145 psig

2.0

2.6

 

 

 

 

 

 

 

EC/ECT-03-120

1.20

F5

1.00 60° W DEL

145 psig

3.0

2.9

 

 

 

 

 

 

 

EC/ECT-04-125

1.25

F5

1.00 60° W DEL

155 psig

2.5

3.4

 

 

 

 

 

 

 

EC/ECT-04-150

1.50

F10

1.25 60° B DEL³

145 psig

1.5

3.1

 

 

 

 

 

 

 

EC/ECT-04-175

1.75

F10

1.35 60° B DEL

165 psig

2.0

2.5

 

 

 

 

 

 

 

EC/ECT-05-175

1.75

F10

1.35 60° B DEL³

165 psig

2.0

2.5

 

 

 

 

 

 

 

EC/ECT-05-200

2.00

F10

1.50 60° B DEL

170 psig

2.5

2.8

 

 

 

 

 

 

 

EC/ECT-05-250

2.50

F10

2.00 60° B DEL³

155 psig

3.5

4.2

 

 

 

 

 

 

 

EC/ECT-06-275

2.75

F10

2.25 60° B DEL³

150 psig

4.0

4.2

 

 

 

 

 

 

 

EC/ECT-06-300

3.00

F10

2.50 60°B DEL

145 psig

4.5

4.2

 

 

 

 

 

 

 

Factory Installed Nozzles (Packaged Boilers or Burner Cartons) are indicated in Boldface.

1Requires Low Firing Rate Baffle

2Remove Static Plate for 1.20 GPH Rate

3Shipped Loose with Packaged Boiler or Burner Carton

16

Image 18
Contents Series EC/ECT Table of Contents Using this Manual Installation ClearanceSpecial Attention Boxes AIR for Combustion and Ventilation PreinstallationClearances Never burn garbage or paperChimney / Vent and Draft Control Installation SurveyOld New Comments Installation Planning the LayoutObservation Cover Assembly Knockdown Boilers Boiler Placement and AssemblySetting the Boiler Jacket AssemblyBoiler Exploded View See .1 in for parts identification Piping and Controls Pressure Test Block AssemblyDo not pipe boiler before jacket is Notice installed Boiler Return ClearanceWater Boiler Piping Water Boiler PipingMaximum Tankless Water Heater Ratings Heater No Capacity Boiler SeriesControls Use only the Hydrolevel CG450 asBurner Wiring ElectricalGeneral Steam Boiler with Probe Low Water Cut-Off Water Boilers Zoning with Zone Valves Burner START-UP and Adjustment Burner Setup & Boiler OperationBurner Installation Check Boiler ControlsClean the Boiler Steam Boilers only Cleaning the boiler requires the use85 70 a DEL Model NoAir Band Model No Shutter Pressure Head Dim. a Air BandMaintenance Maintenance of Safety Relief Valve Daily Maintenance with Boiler OperatingWeekly Maintenance with Boiler Operating Monthly Maintenance with Boiler OperatingIf a Long Shutdown is Required Burner mounting plate must beOpened to facilitate this operation Boiler Dimensions & Ratings Width Depth HeightLocation Size NPT Water Steam Net I=B=R Ratings4 Output5Input Water SteamRepair Parts EC/ECT-03 EC/ECT-04 EC/ECT-05 EC/ECT-06Page Page Series EC/ECT

ECT Series, EC Series specifications

The PB Heat EC Series and ECT Series represent a significant advancement in residential and commercial heating technology, providing reliable and efficient solutions for a variety of heating applications. These series are designed to meet the needs of homeowners and businesses seeking dependable heating while also prioritizing energy efficiency and comfort.

One of the standout features of the EC Series and ECT Series is their advanced engineering, which includes a range of high-efficiency boilers. These units utilize a cast iron heat exchanger that ensures excellent thermal transfer and durability. The cast iron construction is known for its longevity, enabling these boilers to withstand high temperatures and pressures, which is essential for long-term performance and reliability.

In terms of efficiency, both series feature energy-saving technologies that comply with the latest environmental standards. The EC Series, for example, boasts an impressive Annual Fuel Utilization Efficiency (AFUE) rating, indicating that a significant portion of the fuel consumed is converted into usable heat. This results in lower fuel bills and a reduced carbon footprint. The ECT Series further enhances efficiency with features like modulating burners that adjust the heat output based on demand, providing optimal comfort while minimizing energy waste.

Another notable characteristic of these series is their user-friendly controls and digital interfaces. The boilers come equipped with intuitive controls that allow homeowners to easily set and monitor their heating preferences. Many units also support advanced features, including Wi-Fi connectivity, enabling users to manage their heating systems remotely via smartphone applications.

In addition to their efficiency and user-friendly design, the PB Heat EC and ECT Series prioritize safety. These boilers incorporate multiple safety features, such as pressure relief valves and low water cut-off mechanisms, which help prevent operational hazards and ensure safe operation.

Overall, the PB Heat EC Series and ECT Series offer a robust combination of advanced heating technologies, efficiency, and safety. With their durable construction, energy-saving capabilities, and user-friendly controls, these heating solutions are ideal for those looking to invest in reliable and efficient heating systems. Whether for a residential property or a commercial facility, the EC and ECT Series stand out as exceptional choices in the modern heating landscape.