Nordmende 2401935EN0801 manual Steam Nozzle, Dimensions of the steam distribution pipes

Page 5

Dimensions of the steam distribution pipes

Type

A (mm)

B (mm)

C (mm)

D (mm)

Fig.

Art. no.

 

 

 

 

 

 

 

22-300

300

Ø 22

176

60

3.6

902 00 00

 

 

 

 

 

 

 

22-450

450

Ø 22

300

70

3.6

902 00 01

 

 

 

 

 

 

 

22-650

650

Ø 22

504

70

3.6

902 00 02

 

 

 

 

 

 

 

22-850

850

Ø 22

696

70

3.6

902 00 03

 

 

 

 

 

 

 

 

 

 

 

 

 

 

35-300

300

Ø 35

200

55

3.6

902 00 04

 

 

 

 

 

 

 

35-450

450

Ø 35

300

80

3.6

902 00 05

 

 

 

 

 

 

 

35-600

600

Ø 35

425

90

3.6

902 00 06

 

 

 

 

 

 

 

35-900

900

Ø 35

680

110

3.7

902 00 07

 

 

 

 

 

 

 

35-1200

1200

Ø 35

935

110

3.7

902 00 08

 

 

 

 

 

 

 

35-1500

1500

Ø 35

1275

110

3.7

902 00 09

 

 

 

 

 

 

 

A

 

100x100

 

 

C

D

 

 

 

 

 

 

B

 

 

 

 

3%

 

 

 

 

 

 

105

116

138

ø8

 

116

 

 

 

 

 

 

Fig. 3.6

A

D

100

 

C

 

 

M6

75

 

3%

 

 

B

118

130

150

 

ø8

 

 

 

Fig. 3.7

3.2 Steam Nozzle

For smaller outputs of up to 4 kg/h steam, we offer a nozzle which can be either fitted in air ducts, for instance, or used for direct room humidification. The rules for vaporisation lines (lines needed to mix the steam adequately with air) must be observed here too.

!When the steam nozzle is used, the length of the steam hose should not exceed 1.5 meters.

Fig. 3.8

5

Image 5
Contents Nordmann econoVap Introduction List of contentsHow the humidifier works Safety InstructionsDimensions InstallationDimensions of the units Positioning HumidifierSteam Nozzle Dimensions of the steam distribution pipesDimensions of the steam blowers 4-23 kg/h Fitting the humidifier General guidelines for the installationFitting the steam-distribution pipe Various fitting methodsSteam-distribution pipe fitted on suction side Fitting the blowersMinimum distances for steam blowers 4-23 kg/h Minimum distances for steam blowers 32-65 kg/hInstallation Material Technical specifications steam blowersPossible installation Laying the steam hoseWater quality Water connectionsWater intake and drainage Safety instructionsElectrical connections Control voltagePutting the humidifier into operation Setting the output limitationStart-up LED DisplayRemote indication Safety functionsSystem- and servicing indications Rectifying faults MaintenanceRegular checks Replacing the steam cylinderOptions Taking the humidifier out of operationProportional adaptor SC-System4564 Technical specifications