Kirby Air Control System manual Communications Panel, Kmacs 5 Exploded Views & Parts Lists

Page 27

KMACS 5 MANUAL

KMACS 5 EXPLODED VIEWS & PARTS LISTS

Communications Panel

Key#

Part #

Description

1

530-017

Screw

2

415-105

Communicator

3

530-035

Screw

4

430-075

Washer

5

410-003

Gasket, Foam

6

445-105

Panel, Auxiliary

7

450-106

Yoke Retainer

8

420-125

Arrow, Orange

9

420-120

Arrow, Blue

10

445-115

Door, Storage Compartment

11

420-160

Slide Latch

12

330-405

Lock washer

13

530-070

Screw

14

420-105

Box, Plastic

15

410-145

Grommet

16

415-110

Cable, Battery

Key#

Part #

Description

17

415-056

Battery, Gel Cell 12V

18

430-060

Retainer Ring

19

455-065

Filter

20

510-491

O-Ring

21

455-317

Yoke/Din Assembly (18-21)

 

 

 

22

410-006

Hose Protector, Orange

 

410-007

Hose Protector, Blue

23

455-054

Hose, H.P. Supply

24

405-175

Hose, Yoke Assem., Blue (18-23)

 

405-176

Hose, Yoke Assem., Orange (18-23)

 

 

 

25

455-135

Conical Seal

400-046 KMACS 5 with Communicator

400-045 KMACS 5 No Communicator

Bracket for no comm version not shown

440-004

Mount Bracket

530-078

Screw

 

530-540

Washer

 

© 2003 KMDSI Document # 041112001

21

 

Image 27
Contents Kmdsi Kirby Morgan Air Control SystemThis page not used Definitions of Signal Words Used in this Manual Warranty Information Table of Contents Page Kmacs 5 Kirby Morgan Air Control System DefinitionsDivers with all of the gear they need to dive Design PurposeSpecifications General DescriptionLow Pressure Supply Pressure Maximum Breathing AIR Subsystem Principle Operating FeaturesLOW Pressure Inlet Fitting N Orange AIR Supply Flow Indicator LinesCase J Blue Breathing AIR Supply Pressure Gauge MOrange Breathing AIR Supply Pressure Gauge L Yokes for High Pressure Cylinder Attachment SPneumo Valve KNOB, RED Diver Regulator Adjustment Knob for Umbilical Pressure HOutlet Manifold Including DIVER’S Umbilical Fittings G Pneumo Valve KNOB, White DiverConnecting the AIR Supply Unpacking the KmacsFirst USE of the Kmacs Connecting DIVER’S Hoses to the Kmacs PRE-DIVE Check Suggested Regulator settings for the KmacsMetric Suggested Regulator settings for the Kmacs Testing L.P. SupplyTesting Communications Testing the Pneumo Preparing the DiverDive Supervisor and the Kmacs 5 Operator Descent Procedures During the DIVER’S Ascent Diver AT DepthChanging OUT High Pressure Cylinders Completion of Diving Operations DecompressionReplacing the Battery Recommended Maintenance of the KmacsSymptoms Probable Causes Remedy GeneralNo Communications Symptoms Probable Cause Remedy No Pneumo ReadingNo AIR to Diver Appendix Emergency ProceduresProblem Action Diver Line Pull SignalsLocation Description Communications Wiring SchematicsExploded Views & Parts Lists Location Description QtyCommunications Panel Kmacs 5 Exploded Views & Parts ListsPanel Mounted Plumbing and Gauges Interior Plumbing Arrangement Kmacs 5 Dive LOG Table of Equivalents