13.REGULATOR ADJUSTMENT KNOB FOR UMBILICAL PRESSURE (H)

The regulator Adjustment Knob (H) allows the operator to adjust the umbilical pressure within a range of 115 psi to 225 psi (8-15.5 bars). Incoming high pressure air from the ‘ORANGE” or “BLUE” supply is reduced by the internal regulator. The Adjustment Knob controls the regulator. Turning the Knob clockwise decreases the umbilical pressure; counterclockwise increases it.

14.OUTLET MANIFOLD INCLUDING DIVER’S UMBILICAL FITTINGS (G)

The “WHITE DIVER” and “RED DIVER” air supply hoses are connected to the KMACS 5 at the manifold (G). The fittings coming out of the KMACS 5 are male #6 JIC (3/8”, 37°) flared fittings. The diver’s air supply hoses must have matching female #6 JIC flared fittings with swivel nuts.

The “WHITE DIVER” and “RED DIVER” pneumo- fathometer hoses are also connected to the KMACS 5 at the manifold (G). The fittings coming out of the KMACS 5 are male #4 JIC ( 1/4”, 37°) flared fittings. The diver’s pneumofathometer hoses must have matching female #4 JIC (1/4”, 37°) flared fit- tings with swivel nuts.

15.PNEUMO VALVE KNOB, WHITE DIVER

(O)

The Pneumo Valve Knob, White Diver turns on and off the air supply to the “WHITE” pneumofathometer system.

16.PNEUMO VALVE KNOB, RED DIVER

(D)

The Pneumo Valve Knob, Red Diver turns on and off the air supply to the “RED” pneumofathometer system.

KMACS 5 MANUAL

17. O-RING SEAL (U)

The O-ring seal helps keep dust and moisture out of the KMACS 5 when the case is closed. The O-ring seal is not pressure proof, however, and the KMACS 5 case will flood if the box is submerged.

18. COMMUNICATOR PANEL (V)

The diver’s electronic communicator (R) is attached to the communicator panel. The battery for the com- municator is located behind this panel.

19. COMMUNICATOR (R)

The MK3-KMDSI communicator is a standard open circuit/round robin diver’s communicator, which functions like a telephone. It can also be used as a 2 wire, “push-to-talk” system. It is connected to the diver’s umbilicals by “banana plug” fittings on the communicator. The communicator is mounted on the communicator panel. You should read and understand the accompanying radio operations manual supplied with the unit before using the unit. Improper use or connections could damage the radio.

CAUTION: Never connect the charger during a dive or when anyone is in contact with connected equipment. Although electrical shock danger is remote, connection of the recharging cord should only be done when the KMACS 5 is not in use.

© 2003 KMDSI Document # 041112001

Image 13
Contents Kmdsi Kirby Morgan Air Control SystemThis page not used Definitions of Signal Words Used in this Manual Warranty Information Table of Contents Page Kmacs 5 Kirby Morgan Air Control System DefinitionsDivers with all of the gear they need to dive Design PurposeGeneral Description SpecificationsLow Pressure Supply Pressure Maximum Breathing AIR Subsystem Principle Operating FeaturesLOW Pressure Inlet Fitting N Orange AIR Supply Flow Indicator LinesOrange Breathing AIR Supply Pressure Gauge L Blue Breathing AIR Supply Pressure Gauge MYokes for High Pressure Cylinder Attachment S Case JOutlet Manifold Including DIVER’S Umbilical Fittings G Regulator Adjustment Knob for Umbilical Pressure HPneumo Valve KNOB, White Diver Pneumo Valve KNOB, RED DiverUnpacking the Kmacs Connecting the AIR SupplyFirst USE of the Kmacs Connecting DIVER’S Hoses to the Kmacs Metric Suggested Regulator settings for the Kmacs Suggested Regulator settings for the KmacsTesting L.P. Supply PRE-DIVE CheckTesting Communications Preparing the Diver Testing the PneumoDive Supervisor and the Kmacs 5 Operator Descent Diver AT Depth Procedures During the DIVER’S AscentChanging OUT High Pressure Cylinders Completion of Diving Operations DecompressionReplacing the Battery Recommended Maintenance of the KmacsGeneral Symptoms Probable Causes RemedyNo Communications No Pneumo Reading Symptoms Probable Cause RemedyNo AIR to Diver Problem Action Emergency ProceduresDiver Line Pull Signals AppendixExploded Views & Parts Lists Communications Wiring SchematicsLocation Description Qty Location DescriptionCommunications Panel Kmacs 5 Exploded Views & Parts ListsPanel Mounted Plumbing and Gauges Interior Plumbing Arrangement Kmacs 5 Dive LOG Table of Equivalents