Kirby 5, Air Control System manual Table of Contents

Page 5

Table of Contents

Section

Title

Page #

1.0

General Information

 

1

1.1

Definitions

 

1

1.2

Design Purpose

 

2

1.3

Specifications

 

3

1.4

General Description

 

3

1.4.1

Breathing Air Sub System

 

4

1.4.2

Principle Operating Features

 

4

 

1.

Dive Control Panel

 

4

 

2.

Red Diver Depth Gauge

 

4

 

3.

Umbilical Pressure Gauge

 

4

 

4.

White Diver Depth Gauge

 

4

 

5.

Blue Air Supply Flow Indicator Line

 

4

 

6.

Orange Air Supply Flow Indicator Line

5

 

7.

Low Pressure Inlet Fitting

 

5

 

8.

Blue Breathing Air Supply Gauge

 

6

 

9.

Orange Breathing Air Supply Gauge

 

6

 

10.

High Pressure Cylinder Yokes

 

6

 

11.

Bottom of Case

 

6

 

12.

Air Supply Selector Valve Handle

 

6

 

13.

Regulator Adjustment Knob

 

6

 

14.

Outlet Manifold

 

7

 

15.

Pneumo Valve Handle, White Diver

 

7

 

16.

Pneumo Valve Handle, Red Diver

 

7

 

17.

O-Ring Seal

 

7

 

18.

Communicator Panel

 

7

 

19.

Communicator

 

7

2.0

Operating Instructions

 

8

2.1

Unpacking the KMACS 5

 

8

2.2

First Use of KMACS 5

 

8

Section

Title

Page #

2.3

Connecting the Air Supply

8

2.4

Connecting Diver’s Hoses

9

2.5

Pre-Dive Checklist

10

2.5.1

Testing the L.P. Supply

10

2.5.2

Testing Communications

11

2.5.3

Testing the Pneumo

12

2.6

Preparing the Diver

12

2.7

Dive Supervisor and KMACS Operator

12

2.8

Descent

13

2.9

Diver at Depth

14

2.10

Changing out High Pressure Cylinders

14

2.11

Procedures During the Diver’s Ascent

14

2.12

Decompression

15

2.13

Completion of Diving Operations

15

3.0

Maintenance

16

3.1

Recommended Maintenance

16

3.2

Replacing the Battery

16

4.0Troubleshooting

17

4.1

General

17

4.2

No Communications

17

4.3

No Pneumo Reading

18

4.4

No Air to the Diver

18

5.0

Appendix

19

5.1

Emergency Procedures

19

5.2

Diver Line Pull Signals

19

5.3

Communications Wiring Schematics

20

5.4

Exploded Views & Parts Listz

20

5.5

Dive Log Master Sheet

24

Image 5
Contents Kmdsi Kirby Morgan Air Control SystemThis page not used Definitions of Signal Words Used in this Manual Warranty Information Table of Contents Page Kmacs 5 Kirby Morgan Air Control System DefinitionsDivers with all of the gear they need to dive Design PurposeLow Pressure Supply Pressure Maximum SpecificationsGeneral Description Breathing AIR Subsystem Principle Operating FeaturesLOW Pressure Inlet Fitting N Orange AIR Supply Flow Indicator LinesOrange Breathing AIR Supply Pressure Gauge L Blue Breathing AIR Supply Pressure Gauge MYokes for High Pressure Cylinder Attachment S Case JOutlet Manifold Including DIVER’S Umbilical Fittings G Regulator Adjustment Knob for Umbilical Pressure HPneumo Valve KNOB, White Diver Pneumo Valve KNOB, RED DiverFirst USE of the Kmacs Connecting the AIR SupplyUnpacking the Kmacs Connecting DIVER’S Hoses to the Kmacs Metric Suggested Regulator settings for the Kmacs Suggested Regulator settings for the KmacsTesting L.P. Supply PRE-DIVE CheckTesting Communications Dive Supervisor and the Kmacs 5 Operator Testing the PneumoPreparing the Diver Descent Changing OUT High Pressure Cylinders Procedures During the DIVER’S AscentDiver AT Depth Completion of Diving Operations DecompressionReplacing the Battery Recommended Maintenance of the KmacsNo Communications Symptoms Probable Causes RemedyGeneral No AIR to Diver Symptoms Probable Cause RemedyNo Pneumo Reading Problem Action Emergency ProceduresDiver Line Pull Signals AppendixExploded Views & Parts Lists Communications Wiring SchematicsLocation Description Qty Location DescriptionCommunications Panel Kmacs 5 Exploded Views & Parts ListsPanel Mounted Plumbing and Gauges Interior Plumbing Arrangement Kmacs 5 Dive LOG Table of Equivalents