Appendix: Installation

2. Location

2-1 Indoor unit

WARNING: Maintain the required space around the

appliance to prevent overheat.

The area for installation of the appliance should not be in an area with the following:

Di rect sunlight

H eat resource

Inflammable gas

Thick oil fog

The appliance should be installed in an area,

Where the inside space can be evenly conditioned, or

Which is strong enough for the appliance, or,

Having the shortest distance for the copper tubes and water drain hose, and

Having desired space around the appliance for maintenance and ventilation.

Min. 5cm

Min. 5cm

Min. 5cm

Tube arrangement

L

H

Add. Refrigerant

Provided Tube(M)

 

 

(g/m)

 

 

 

 

 

15

7

25

4

L:Maximum length of the tube connecting the indoor unit and the outdoor unit.

H:The height difference between the indoor unit and the outdoor unit.

Tube length(L)

Indoor unit

Height difference(H)

Outdoor

 

unit

If the length of the tube is between 7.5m to 15m(maximum length), an additional 25g/m of refrigerant should be added . Additional compressor oil must not be added.

CAUTION: The indoor unit should not be installed below a height of 1.8m.

2-2 Outdoor unit

The outdoor unit should be installed away from the following: Heat source and fan exhausting ;

Director sunlight;

8

The outdoor unit should be installed in an area with, Cool temperature;

Good ventilation;

Desired space for air inlet, outlet and maintenance

 

Top obstacle

Air inlet

Min. 10cm

 

 

Valve side

 

 

outletAir

 

 

Min. 25cm

Blockage

Min. 5cm

Air outlet

 

Min. 40cm

 

 

Ground

Min.10cm

 

 

Air inlet

Strong base (10x40cm2 concrete or alike). The appliance should be placed not less than 10cm high.

Anchor bolts(4)

Air inlet

Min. 10cm

Concrete or alike

Abo

 

 

10cm

ut

4

About

 

0cm

 

 

 

 

 

Fix the base with anchor bolts to reduce vibration and noise.

20

Image 22
Contents Instruction Manual Installation Compact Size Contents Alert SymbolsPage Composition of the Air Conditioner Timer lamp Hipower lampPower lamp ON/OFF buttonSymbols Transmitter HR. Timer button High Power buttonTimer ON/OFF button Sleep buttonFlap button HR Timer buttonAutomatic switching between cooling and heating FAN Speed selectorHOW to Install Batteries Operation GuideOperation with the Remote Control Unit Adjusting the Airflow Direction Adjusting the Fan SpeedHorizontal Setting procedure High Power Operation¡ñNight Setback Mode Cancellation proceduresTimer OFF mode Example Using the 12-Hour on and OFF TimerTimer on mode Example Setting ProceduresUsing the 1-Hour OFF Timer Cancellation procedureSpecial Remarks Care and Cleaning Operation without the Remote Control UnitCare and Cleaning Troubleshooting Tips for Energy SavingSchematic Diagram Refrigerant Flow DiagramAppendix Installation SummeryLocation Installation of the indoor unit Installation of the outdoor unit Air purging Knob of the manifold valve mustAir Purging with a Vacuum Pump for Test Run Packing List

KFR-3208GW specifications

Hisense Group, a key player in the global consumer electronics market, has made significant advancements in air conditioning technology with its model KFR-3208GW. Designed to meet the demands of both comfort and energy efficiency, this air conditioning unit stands out for its impressive blend of features and modern technologies.

One of the main features of the KFR-3208GW is its powerful cooling capability. With a cooling capacity of 3.2 kW, this unit can quickly lower indoor temperatures, making it ideal for residential and small commercial settings. The inverter technology integrated into the KFR-3208GW allows for precise temperature control while ensuring lower energy consumption, leading to substantial cost savings on electricity bills. This technology enables the compressor to adjust its speed according to the room temperature, thus maintaining a consistent climate without unnecessary energy spikes.

Another highlight of this air conditioning system is its Quiet Operation mode. The KFR-3208GW is designed to operate at low noise levels, making it suitable for bedrooms and other quiet environments. This is especially important for users who prefer a peaceful atmosphere for sleeping or working.

The air conditioning unit also features a multi-functional remote control, allowing users to effortlessly switch between the various modes such as cooling, heating, and dehumidification. The unit is equipped with a precise temperature sensor that ensures optimal performance and enhances user comfort.

Moreover, the KFR-3208GW is designed with advanced filtration systems that improve indoor air quality. The built-in filters are capable of capturing dust, allergens, and other airborne particles, contributing to a healthier living environment. This feature is particularly beneficial for individuals with respiratory issues or allergies.

In terms of installation, the KFR-3208GW offers flexibility, catering to different room layouts. Its compact design allows for easy wall mounting, making it an attractive option for space-constrained areas.

Overall, the Hisense Group KFR-3208GW air conditioning unit combines energy efficiency, cutting-edge technology, and user-friendly features, making it a desirable choice for those looking to enhance their indoor comfort while promoting a healthier atmosphere. As consumers continue to seek reliable and efficient cooling solutions, the KFR-3208GW is well positioned to meet these evolving needs.