GSW JWF657, JWF507 Vacuum Relief Valves, Closed System/Thermal Expansion, Discharge Line/Driptube

Page 13

DO NOT use any pumps, valves, or fittings that are not com- patible with potable water.

DO NOT use valves that may cause excessive restriction to water flow. Use full flow ball or gate valves only.

DO NOT use any lead based solder in potable water lines. Use appropriate tin-antimony or other equivalent material. DO NOT tamper with the aquastat, burner or temperature and pressure relief valve. Tampering voids all warranties. Only qualified service technicians should service these com- ponents.

DO NOT use with piping that has been treated with chro- mates, boiler seal, or other chemicals.

DO NOT add any chemicals to the system piping which will contaminate the potable water supply.

Closed System/Thermal Expansion

Periodic discharge of the temperature and pressure relief valve may be due to thermal expansion in a closed water supply system. The water utility supply meter may contain a check valve, backflow preventer or water pressure-reducing valve. This will create a closed water system. During the heating cycle of the water heater, the water expands caus- ing pressure inside the water heater to increase. This may cause the temperature and pressure relief valve to dis- charge small quantities of hot water. To prevent this, it is rec- ommended that a diaphragm-type expansion tank (suitable for potable water) be installed on the cold water supply line. The expansion tank must have a minimum capacity of 5.6 litres (1.5 US gallons) for every 190 litres (50 US gallons) of stored water and be rated at the working pressure of the water heater. Contact the local water supplier or plumbing inspector for information on other methods to control this sit- uation.

Important: Do not plug or remove the temperature and pressure relief valve.

Temperature and Pressure (T&P) Relief Valve

Water Supply Systems”, ANSI Z21.22/CSA 4.4”. The function of the temperature and pressure relief valve is to discharge water in large quantities in the event of excessive temperature or pressure developing in the water heater. The valve’s relief pressure must not exceed the working pres- sure of the water heater as stated on the data plate.

Important: Only a new temperature and pressure relief valve should be used with your water heater. Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new water heater. Do not place any valve between the relief valve and the tank.

The Temperature and Pressure Relief Valve:

Must not be in contact with any electrical part.

Must be connected to an adequate discharge line.

Must not be rated higher than the working pressure shown on the data plate of the water heater.

The Discharge Line/Driptube:

Must not be smaller than the pipe size of the relief valve or have any reducing coupling installed in the discharge line.

Must not be capped, blocked, plugged or contain any valve between the relief valve and the end of the dis- charge line.

Must terminate a maximum of 300mm (12 in.) (Canada) or 150mm (6 in.) (U.S.A.) above the floor.

Must be capable of withstanding 121°C (250°F) without distortion.

Must be installed to allow complete drainage of both the valve and discharge line.

NOTE: Rear and Combination flue units must be fitted with a T&P Relief Valve WATTS type 40XL-5 or equivalent.

Failure to install and maintain a new, properly listed temperature and pressure relief valve will release the manufacturer from any claims which may result from excessive temperature or water pressure.

WARNING

Explosion Hazard

If the temperature and pressure relief valve is dripping or leaking, have a licensed plumber repair it.

Do not plug valve.

Do not remove valve.

Failure to follow these instructions can result in death or an explosion.

For protection against excessive pressures and tempera- tures, a temperature and pressure relief valve must be installed in the opening marked “T&P RELIEF VALVE”. This valve must be design certified by a nationally recognized testing laboratory that maintains periodic inspection of the production of listed equipment or materials as meeting the requirements of the “Standard For Relief Valves For Hot

Vacuum Relief Valves

A vacuum relief valve, installed in the cold water supply line above the top of the water heater, shall protect the water heater against siphoning (loss of water due to loss of supply pressure). Where heating equipment has a bottom supply, the cold water supply piping shall be carried above the top of the heater before being routed to the supply connection and have a vacuum relief valve installed in it at a level above the top of the storage tank. The vacuum relief valve shall be in compliance with the latest edition of “Standard For Relief

Valves For Hot Water Supply Systems, ANSI Z21.22/CSA 4.4”.

– 13 –

Image 13
Contents What to do if YOU Smell OIL For Your SafetyImmediately call your oil supplier Table of Contents For Installations in Canada II SafetyIntroduction Consumer ResponsibilitiesSafety Warning Flammable Vapours For Installations in the United StatesSafety Warning Scalding Relief Valve Requirements T&PIII Installation Oil Supply Clearances and AccessibilityEarthquake Zones JWF307V Model JWF307 JWF507 JWF657 Air Requirements Where the water heater is locatedAir Supply Ducted Furnace Room And/or roomVent and Exhaust Connections Power Venting Blocked Vent Safety SwitchWater Supply Plumbing Connections Center Flue Filling the Water HeaterVacuum Relief Valves Temperature and Pressure Relief ValveClosed System/Thermal Expansion Discharge Line/DriptubeElectrical Supply Installation Of The Aquastat Temperature Control48245 Water Temperature Regulation Installation ChecklistIV Operation Water Heater Sounds Anode MaintenanceSmoke/Odour Anode Rod/Water OdourMaintenance Re-Starting The Heater After Shut- Down Shut Down For Extended PeriodsVI Combo Heating Combo Heating Baseboard InstallationVII OIL Burner Listing Beckett AFG GSW-J5006 ~ Certificate of Warranty ~

JWF657, JWF507 specifications

The GSW JWF657 and JWF507 are two prominent models in the GSW lineup, known for their innovative features, advanced technologies, and robust characteristics. These models have been designed to cater to a wide range of applications, making them popular choices among users looking for efficient performance and reliability.

Starting with the JWF657, this model boasts a high-capacity design, making it suitable for both residential and commercial use. One of its standout features is the energy-efficient motor that not only reduces power consumption but also enhances performance. The JWF657 includes a user-friendly control panel that allows for easy adjustments and settings, ensuring that users can operate the machine with minimal effort.

In terms of technology, the JWF657 integrates smart sensors that monitor operational parameters in real-time. This feature ensures that the equipment runs at optimal efficiency, reducing wear and tear while extending the lifespan of the product. Another noteworthy attribute is the noise reduction technology, which minimizes operational sound, making it ideal for environments where noise levels need to be kept to a minimum.

On the other hand, the JWF507 model is tailored for those who prioritize compactness without compromising performance. Its sleek design makes it a perfect fit for smaller spaces, while its powerful engine ensures that it can handle demanding tasks with ease. The JWF507 also includes advanced safety features such as automatic shut-off systems and overload protection, ensuring user safety and preventing equipment damage.

Both models are equipped with advanced filtering technologies that promote better air quality and energy conservation. They come with durable construction materials that can withstand harsh conditions, ensuring longevity and reliability. Additionally, routine maintenance is simplified with easy access points for cleaning and servicing.

In summary, the GSW JWF657 and JWF507 are engineered for excellence, combining innovative features with user-friendly designs to offer optimal performance. Whether you need high capacity or compact efficiency, these models stand out in the market for their reliability, safety features, and advanced technologies. Users can trust these products to deliver consistent results while being easy to maintain and operate.