GSW G65 instruction manual For the Installer and User of this GAS Fired Water Heater, Location

Page 2

IMPORTANT

FOR THE INSTALLER AND USER OF THIS GAS FIRED WATER HEATER

These instructions have been written for the proper installation and safe operation of this water heater. The installation must conform with one or more of the follow- ing as applicable:

Canadian Installation:

1.The latest edition of CAN/CGA B149.

2.Public Utility and/or local Codes

U.S. Installation:

1.Public Utility and/or local Codes

2.The latest edition of the National Fuel Gas Code ANSI Z 223.1/NFPA 54

WARNING

This water heater must be installed strictly in accordance with the detailed instructions enclosed and local building codes. It must be installed with a proper temperature and pressure relief valve which may release water in normal oper- ation. It is also possible that connections to the water heater, or the water heater itself may develop leaks. IT IS THERE- FORE IMPERATIVE that the water heater be installed so that any water is directed to an adequate drain in such a way that it cannot damage the building, furniture, carpeting or other property subject to water damage. THE COMPANY CANNOT BE HELD RESPONSIBLE for damage caused by water from the water heater, pressure relief valve or related fittings where adequate provision to drain such water has not been made. Closets without drains and carpeted areas are examples of unsuitable locations for any water heater.

The warranty on this water heater is in effect only when the heater is installed and operated in accordance with these instructions. The manufacturer of this heater will not be liable for any damage resulting from failure to comply with these instructions.

IMPORTANT: Before starting the installation read the rating plate on the heater. The gas listed must be the same as the gas supplied to the premises. A heater designed for Natural Gas must only be hooked up to a natural gas supply, and likewise, a heater designed for Propane Gas must only be hooked up to propane.

DO NOT PROCEED UNLESS GAS TYPE OF HEATER AND GAS SUPPLY HAVE BEEN IDENTIFIED TO BE THE SAME.

LOCATION

Location selected should be as close to the stack or chimney as practical and as centralized with the piping system as pos- sible. Heater should be located in an area not subject to freezing temperatures.

The water heater should be located so that the controls and drain are easily accessible. The heater should be located in an area where leakage of the tank or connections will not result in damage to the area adjacent to the water heater or to lower floors of the structure. When such locations cannot be provided, it is recommended that a suitable drain pan be installed under the heater. Such pans should be a maximum 2” deep and have a minimum length and width at least two inches greater than the diameter of the water heater and should be piped to an adequate drain. The pan must not restrict combustion air flow.

Under no circumstances is the manufacturer to be held liable for any water damage in connection with this water heater.

The water heater must be level on the floor surface.

Any enclosure surrounding the installation must allow an ade- quate supply of ventilation and combustion air to the water heater. Otherwise sufficient air must be drawn from outside the enclosure. Air may be drawn into the enclosure through an opening. The opening shall have a free area of 1 square inch per thousand BTU’s and be located below 18 inches and above 6 inches as measured to the floor.

Chemical vapour corrosion can occur anywhere that flue gases are carrying cleaning solvents, refrigerants, pool chem- icals, chlorine salts. The location of the water heater should not be near any of these chemicals.

Minimum clearances from the water heater and venting arrangement to combustible materials are: ( See also Fig. 1 and 2).

Electronic Ignition Model -G65

3 inches from sides

3 inches from back

6 inches above vent pipe

Electronic Ignition Models - (all others) 6 inches from sides

6 inches from back

6 inches above vent pipe

Standing Pilot Models 6 inches from sides 6 inches from back

6 inches above vent pipe

CAUTION: When this heater is installed directly on carpeting, carpeting must be protected by a metal or wood panel beneath the appliance, extending beyond the full width and depth of the appliance by at least 3 inches in any direction. If the appliance is installed in an alcove, the entire floor must be covered by the panel. Failure to heed this warning may result in fire hazard.

Page 1

Image 2
Contents Commercial GAS Water Heater What to do if YOU Smell GASFor the Installer and User of this GAS Fired Water Heater LocationRating at tank Water supply to meter Water supply to home Water Piping Pressure Build-up in a Water SystemPropane BTUInput SQ. VentingDIA Area Input Natural GAS Propane BTU/HROpen Position Flue DamperDamper Shaft Position Closed PositionValve and Ignition Module Connection Diagram Appliance in Standby ConditionSchematic Valve and Ignition Module On Appliance Call for Heat Stage Schematic Diagram Connection Diagram For Your Safety Read Before Lighting Mechanical Power Venting OptionInstallation Check List AIR SupplyLighting Instructions White Rodgers GAS Controls Hotter Water Increases the Risk ScaldLighting Instructions For Electronic Ignition GAS Models What Do You Do If You Smell Gas?Commercial GAS E.I. Troubleshooting Sequence For Honeywell ValveLP. GAS is Heavier than AIR Maintenance InstructionsLP Propane GAS Models Correct ANY Defects ImmediatelyTemperature Temperature Pressure Relief ValveWater Temperature Regulation General HousekeepingDishwashing Machine Requirements Water Odor ProblemsCathodic Protection Multiple Heaters in Single SystemTWO Temperature Single Temperature or BoosterPRE-HEATER With Horizontal Storage Tank With Vertical Storage TankTemperature Pressure Relief Valve Installation Record ScheduleWarranty Three Year Warranty Model no Serial no

G65 specifications

The GSW G65 is a notable entry in the world of heavy-duty machinery, specifically designed for tasks that demand reliability and performance under challenging conditions. At the forefront of its features is a powerful engine that ensures optimal performance with robust torque delivery. This machine is equipped with a high-efficiency, state-of-the-art powertrain that maximizes productivity while minimizing fuel consumption.

One of the standout characteristics of the GSW G65 is its exceptional lifting capacity, making it suitable for a variety of applications including construction, mining, and agricultural sectors. The G65 can lift and transport heavy loads with ease, enhancing operational efficiency. Safety is paramount, and the G65 incorporates advanced stability control systems, ensuring operators can work confidently even in difficult environments.

The GSW G65 also boasts cutting-edge technologies that elevate its performance standards. A sophisticated hydraulic system allows for smooth operation, enabling precise movements necessary for intricate tasks. This hydraulic innovation provides the machine with rapid response times and reduced downtime, vital components for any project requiring efficiency.

Furthermore, the G65 is designed with operator comfort in mind. The cabin includes ergonomic seating and intuitive controls, ensuring that operators can remain productive throughout their shifts without the burden of discomfort. Additionally, with advanced noise reduction features, the cabin environment is conducive to focus and safety.

Durability is a key attribute of the GSW G65. Built with high-strength materials, the machine is designed to withstand the rigors of demanding work environments. Its maintenance-friendly design allows for easy access to components, simplifying routine checks and servicing.

In terms of technology, the G65 comes equipped with a smart monitoring system that provides real-time feedback on performance metrics, helping operators stay informed of the machine's condition. This feature enhances preventative maintenance practices, reducing the likelihood of unexpected breakdowns.

Overall, the GSW G65 stands out as a formidable machine that blends power, efficiency, and advanced technology. Its robust features and focus on operator safety and comfort make it an indispensable tool in industries that require heavy lifting and reliability. The G65 is not just a machine; it represents a commitment to excellence and innovation in heavy-duty applications.