Deltech Fitness 8000 instruction manual Normal

Page 10

NORMAL OPERATION — The green NORMAL OPERATION indicator will light when the tempera- ture inside the evaporator (chiller ) is normal.

CHECK OPERATING CONDITIONS — The red CHECK OPERATING CONDITIONS indicator will light when the temperature inside the evaporator is too high.

SERVICE DUE — The yellow SERVICE DUE indi- cator will light under three conditions: as a reminder to perform routine maintenance after 4,500 hours of dryer service (approximately six months), when a thermocouple, or when a filter element must be changed.

Table IV

System Operation Monitor Indicating Lights

INDICATING

INDICATES

ACTION REQUIRED

NOTES

LIGHT

 

 

 

 

 

 

 

 

 

This indicator should light within

Indicator will go off if the CHECK

 

 

30 minutes of start-up, after the re-

NORMAL

The temperature inside the evapo-

OPERATING CONDITIONS indica-

OPERATION

rator (chiller) is normal.

frigeration system has stabilized.

tor comes on or when a

It should remain on when the

 

 

thermocouple has failed.

 

 

dryer is operating.

 

 

 

 

 

 

 

 

 

It is normal for this light to be on

 

 

 

when the dryer is first turned on

 

 

 

and remain on until the dryer has

 

 

 

reached normal operating tem-

 

 

 

peratures (about 30 minutes).

 

CHECK

The temperature inside the

If the CHECK OPERATING CON-

Indicator will remain illuminated

OPERATING

DITIONS indicator turns on during

CONDITIONS

evaporator (chiller) is too high.

normal operation, turn the dryer

until problem has been corrected.

 

 

 

 

off to avoid compressor damage.

 

 

 

Have a refrigeration mechanic

 

 

 

identify and correct the malfunc-

 

 

 

tion. If the dryer is under warranty,

 

 

 

call your local distributor for

 

 

 

authorization before servicing

 

 

 

 

 

 

1. 4,500 hours of dryer service

 

See maintenance section in this

 

(approximately six months) has

1. See maintenance section in this

 

manual for instructions on reset-

 

passed; routine maintenance

manual for further instructions.

ting indicator.

 

should be performed.

 

 

 

 

 

 

 

 

 

2. A thermocouple is sensing tem-

 

 

 

perature outside of normal range

 

 

 

or it has failed. The thermocouple

 

 

 

may sense temperatures outside

 

 

 

of normal range for up to two min-

 

Indicator will go off when the dryer

 

utes after startup or in extreme

 

 

2. Check thermocouple. Replace

is turned off. This will not affect

 

temperature conditions. (The al-

 

if necessary.

the 4,500 hour routine mainte-

SERVICE

phanumeric display will read T1,

 

nance indicator.

DUE

T2, T3, T4 or T5 MALFUNCTION.

 

 

 

 

T1 = inlet air, T2 = refrigerant

 

 

 

suction, T3 = refrigerant dis-

 

 

 

charge, T4 = ambient air, T5 =

 

 

 

evaporator.)

 

 

 

 

 

 

 

3. Pressure drop across the prefil-

 

 

 

ter/separator or particulate after

 

 

 

filter indicates the need to replace

1. See maintenance section in this

Indicator will reset when pressure

 

element.

manual for further instructions.

drop returns to normal..

 

Alphanumeric display reads CHG

 

SEPARATOR or CHG PARTICU-

 

 

 

LATE.

 

 

 

 

 

 

 

1. Inlet air temperature is too high.

 

 

 

 

 

 

 

2. Refrigerant suction temperature

Determine which temperature(s) is

 

SYSTEM

is too low.

Indicator will not stop flashing un-

 

out of range. See the Field Serv-

3. Ambient air temperature is too

til the problem has been cor-

ALARM

ice Guide in this manual for possi-

rected.

low.

 

ble causes/remedies

 

 

4. Ambient air temperature is too

 

 

 

high.

 

 

 

 

 

 

6

Pyramid 8000® Series Purifiers (Bulletin 289)

Image 10
Contents Pyramid 8000 Series Compressed Breathing AIR Purifiers Table of Contents Tables Labels and Figures Safety Instructions IntroductionInstallation SafetyReceiving and Inspection Location Ambient Air TemperatureClearance Air Compressor EquipmentDrain Piping Purification ProcessElectrical Connections System Operation Monitor Indicating LightsNormal Temperature SCAN/SEEK Push Button Critical Air and Refrigerant TemperaturesRemote Alarm Contacts Optional Intermediate Air TemperatureRS-232 Serial Port Airflow ADV AdjustmentOperation Start-UpShutdown How to Return Material to Deltech MaintenanceHow to Use the Maintenance Section Replacement PartsMaintenance Procedures Carbon or Catalyst Vessel ReplacementBoom Assembly Coalescing Filter Element ReplacementAfterfilter Element Replacement System Operation Monitor ProgrammingField Service Guide Symptom Possible Cause RemedySymptom Possible Cause Remedy Electrical schematic-Models 8DM25, 8DM50 and 8DM50-E75 Electrical schematic-Models 8DM75, 8DM100 and 8DM150 Electrical schematic-Models 8DM150-E5/E55 Cartridge locations-Model 8DM25 Cartridge locations-Models 8DM50 and 8DM75 Cartridge locations-Models 8DM100 and 8DM150 Models 8DM25, 8DM50 and 8DM75 Models 8DM100 and 8DM150 Deltech

8000 specifications

Deltech Fitness has long been recognized for its commitment to delivering high-quality fitness equipment, and the Deltech Fitness 8000 is no exception. This versatile and robust piece of equipment is designed to cater to both seasoned athletes and fitness enthusiasts alike, boasting an array of features and technologies that enhance the workout experience.

One of the standout characteristics of the Deltech Fitness 8000 is its sturdy construction. Built with heavy-duty steel, it offers impressive durability and stability during intense training sessions. The frame is meticulously designed to withstand rigorous workouts, ensuring that users get the most out of their routines without compromising safety.

The Deltech Fitness 8000 features a multi-functional design, allowing users to perform a variety of exercises with ease. Equipped with adjustable settings, the equipment can accommodate a wide range of workouts, including squats, bench presses, and pull-ups. This versatility makes it an ideal choice for those looking to engage in full-body training.

Incorporating advanced ergonomic design, the Deltech Fitness 8000 ensures that users maintain proper form while exercising. The adjustable components enable a tailored fit, reducing the risk of injury and promoting optimal performance. This user-centric approach not only enhances comfort but also maximizes the effectiveness of each workout.

Another noteworthy aspect of the Deltech Fitness 8000 is its emphasis on technological integration. The equipment may come equipped with features like built-in workout trackers, allowing users to monitor their progress in real-time. This capability fosters motivation and encourages users to set and achieve fitness goals.

Furthermore, the Deltech Fitness 8000 typically includes space-saving features, making it suitable for home gyms or environments with limited space. Its compact design doesn’t compromise on functionality, showing that even smaller setups can provide a comprehensive workout experience.

In summary, the Deltech Fitness 8000 stands out as a top choice for individuals committed to their fitness journey. With its robust construction, multi-functional capabilities, ergonomic design, and advanced technology integration, it empowers users to optimize their workouts while enjoying the benefits of a well-designed fitness machine. Whether you're a beginner or an experienced lifter, the Deltech Fitness 8000 promises to meet your training needs and elevate your fitness regimen.