Defy Appliances Part Number 059 044 installation instructions Installation notes

Page 2

Installation notes.

To ensure optimum performance and customer satisfaction, please read these instructions carefully.

All Defy Console type air-conditioners are tested and rated using the standard Defy wall sleeve and louvre assembly. Units can safely operate up to 43°C outdoor temperature. They have been designed to produce the rated capacity at the lowest power consumption under International Standard Rating conditions.(ISO5151) at 27°C DB, 19°C WB indoor and 35° C DB, 24°C WB outdoor, at sea level and with a 230V 50Hz power supply.

To achieve this performance, the following should be noted:

Smooth curved louvers are used to maximise the condenser airflow requirements.

Air deflectors which guide the air leaving the unit away from the return air openings are fitted onto the condenser coil to minimise hot air re-circulation.

Open cell foam strips are fitted to the condenser end plates and fit tight up against the louvre. These strips effectively prevent unwanted air from entering or leaving the compartments.

To prevent rain water from entering via the wall sleeve, the bottom panel of the sleeve slants outwards . Weep holes at the lower edge allow rainwater to drain away freely.

Architectural and aesthetic requirements often necessitate the use of non standard louver assem- blies. As these could influence the performance of the units, we undertake to test, free of charge, any proposed designs in our calorimeter facility

When specifying non standard louvers, please bear the following in mind:

Defy Appliances Limited, manufactures special wall sleeves without louvers. This sleeve is shorter than standard and thus minimises the gap between the condensing unit and the outside grille Should the factory fitted foam strips not locate against the louver, insulated divider plates must be fitted to prevent hot air re-circulation. It is also recommended to remove the side deflectors from the condenser coil and reposition them directly behind the louvre.

Units installed with flush mounted louvers, need an insulated wall spacer collar to fill the gap be- tween the indoor unit and the outside wall. In this instance part of the condensing section will pro- trude into the room. It is important therefore to insulate the condensing section and to ensure that there are no gaps where heat and noise from the compressor and condenser could enter the room.

Image 2
Contents Console Installation notes Electrical Connection Silhouette Console Installation instructionsPrior to Installation Electrical Connections Split Console installation instructionsInstallation of the Indoor Unit Installation of the Outdoor unit Service TIPElectrical Installation Wiring for Electronic ControlElectrical Connection Curtain Wall Console Installation InstructionPrior to Installation Warranty Defy branch Sales Parts

Part Number 059 044 specifications

Defy Appliances has consistently been at the forefront of innovative home solutions, and their Part Number 059 044 exemplifies this commitment. This appliance is designed with functionality and efficiency in mind, catering to various consumer needs while ensuring exceptional performance.

One of the main features of the Defy 059 044 is its energy-efficient design. As homeowners become increasingly conscious of their environmental footprint, energy efficiency has become a key selling point. The 059 044 model integrates advanced technology to reduce power consumption without compromising performance. This appliance is engineered to meet stringent energy-saving standards, making it a responsible choice for environmentally-minded consumers.

In terms of capacity, the Defy 059 044 boasts a spacious interior that accommodates a variety of cooking and storage needs. This feature is particularly beneficial for busy households, where meal preparation and storage can become a challenge. The adjustable shelving and customizable compartments enhance usability, allowing users to organize their space effectively.

Another notable technology within the Defy 059 044 is its advanced cooling system. This system ensures even temperature distribution, which is crucial for preserving food quality and minimizing spoilage. The appliance is equipped with a frost-free mechanism that eliminates the need for manual defrosting, subsequently saving time and effort for users.

Additionally, the Defy 059 044 prioritizes user-friendly controls. The intuitive interface is designed for ease of use, with straightforward settings that allow users to operate the appliance confidently. The clear display ensures that even those unfamiliar with technology can navigate its features without difficulty.

The design of the Defy 059 044 is both modern and aesthetically pleasing, making it a perfect addition to any contemporary kitchen. Its sleek exterior and neutral color options allow it to blend seamlessly with various decor styles, enhancing the overall look of the space.

Moreover, the Defy 059 044 is built to last, reflecting the brand's reputation for durability and reliability. The high-quality materials used in its construction ensure that the appliance can withstand daily use, providing consumers with peace of mind.

In summary, the Defy Appliances Part Number 059 044 is a well-rounded appliance offering energy efficiency, ample storage, advanced cooling technology, user-friendly controls, and a modern design. It stands as a testament to Defy's dedication to creating appliances that simplify life while delivering exceptional value.