ResMed III ST-A user manual Menu Functions Detailed Menu only, Settings Menu

Page 30

To access the VPAP III ST-A menus:

Press the Left key (menu) while the VPAP (or Ramp) screen is displayed.

To scroll through items within a menu or submenu: Press the Up/Down key.

To enter a submenu: Press the Left key (enter).

To change a setting option for a function:

1.Press the Left key (change).

2.Press the Up/Down key until the desired setting option appears.

3.Press the Left key (apply) to select the setting option.

To exit without changing options: Press the Right key (cancel).

To exit out of a menu or submenu: Press the Right key (exit).

Note: You can return to the VPAP (or Ramp) screen at any time by holding the Right key for at least three seconds.

Menu Functions (Detailed Menu only)

The VPAP III ST-A menu functions are summarized in Tables 2–6 below with a brief description of what each function does and the available setting options. To access these functions, see “How to Use the Detailed Menu (if enabled by your clinician)” on page 20.

Settings Menu

The Settings Menu allows you to view and change certain operating features of the VPAP III ST-A.

Table 2: Settings Menu Functions

Function

Default

Function Description

Setting Options

 

 

 

 

Mask

ULTRA

Selects your mask type.

See “Settings for Mask

 

 

 

Types” on page 23 for

 

 

 

details.

 

 

 

 

Tube Length

2m

Selects the length of air tubing

2m / 3m

 

 

connecting your mask to the

 

 

 

VPAP III ST-A.

 

 

 

 

 

Humidifier

NONE

Selects the type of humidifier to

NONE (HumidAire 2iC),

 

 

be used with the VPAP III ST-A.

PASSOVER,

 

 

 

HUMIDAIRE

 

 

 

If the HumidAire 2i is

 

 

 

used, the above setting

 

 

 

options do not appear

 

 

 

and H2i is displayed.

 

 

 

 

22

Image 30
Contents Vpap III ST-A ROW ENG Illustrations System Components52 cm 3 m 248139/3 05 Manufactured by Contents System Specifications Limited Warranty Index User/Owner Responsibility IntroductionMedical Information What the Vpap III ST-A is Intended forPage Adverse Effects Page Vpap III ST-A System MasksAccessories HumidifiersSetting up the Vpap III ST-A System Setting up the Vpap III ST-AAttaching a HumidAire 2iC Humidifier Attaching a HumidifierAttaching a HumidAire 2i Humidifier Attaching a HumidAire HumidifierAttaching a Passover Humidifier Using the LCD Screen and Keypad LCD ScreenLEDs Keypad Keys Vpap III ST-A keypad has the following keysPage Starting Treatment Ramp TimeUsing the HumidAire 2i Warm-up Feature Using the Mask-Fitting FeatureStopping Treatment High Leak Page Weekly Cleaning Cleaning and MaintenanceDaily Cleaning Periodic CleaningTesting the Alarm Replacing the Air FilterServicing How to Use the Vpap III ST-A Menus How to Use the Standard MenuRamp Screen How to Use the Detailed Menu if enabled by your clinician Settings Summary ScreensMIRAGE, MIR Full STANDARD, Ultra Settings Menu Menu Functions Detailed Menu onlySmartStart Results Menu Options MenuTreatment Screens Servicing MenuOxygen saturation This screen only Level SpO2 98% Non-vented Mask Alarm Screen Page Alarm Mute Key AlarmsAlarms Troubleshooting Testing the AlarmLCD Ipap Lower LCD System Error LCD LOW MV Alarm Starting out Using a Battery to Power the Vpap III ST-AHelpful Hints Nasal IrritationResMed DC-24/30 Converter Troubleshooting No displaySystem Error System Specifications Dynamic pressure characteristicsIEC 60601-1 Classifications Pressure Volume Curve Pressure VariationSymbols which may Appear on the Product Environmental informationEmissions test Compliance Next Portable and mobile RF communications Separation distance according to frequency of transmitter Limited Warranty Page Index Index

III ST-A specifications

The ResMed III ST-A is a state-of-the-art ventilator specifically designed for patients with respiratory challenges, particularly those suffering from obstructive sleep apnea, neuromuscular conditions, or chronic obstructive pulmonary disease (COPD). It stands out due to its user-friendly features, advanced technologies, and robust performance, making it a preferred choice for both clinicians and patients.

One of the main features of the ResMed III ST-A is its intelligent algorithm designed to optimize minute ventilation. This provides variable support that adapts to the patient's breathing patterns, enhancing comfort and ensuring effective ventilation. By offering a range of modes, including spontaneous timed (ST) and volume-assured pressure support (VAPS), this device caters to various clinical needs, facilitating customized therapy based on individual patient requirements.

The built-in leak compensation feature of the ResMed III ST-A allows it to maintain accurate pressure delivery even in the presence of large leaks, which is crucial for ensuring effective therapy. This is particularly beneficial for patients who may have difficulty achieving a proper seal with their masks.

Incorporating advanced technologies, the ResMed III ST-A features AutoSet technology, which automatically adjusts pressure levels in response to detected changes in airflow. This promotes optimal treatment at all times, reducing the burden on patients and allowing for a more seamless sleep experience. The device also supports a range of connectivity options, enabling healthcare providers to monitor patient compliance and therapy effectiveness remotely through ResMed's cloud-based platform.

The ResMed III ST-A is designed with a user-friendly interface, including a bright, easy-to-read display and simplified controls, promoting ease of operation for both healthcare professionals and patients. Its compact size and lightweight design enhance portability, making it suitable for home and travel use.

Furthermore, the device's comprehensive data logging capabilities allow clinicians to access a wealth of information regarding patient adherence and sleep patterns, thus supporting informed decision-making. The ResMed III ST-A also prioritizes patient safety, featuring alarms and alerts for high- and low-pressure conditions.

In conclusion, the ResMed III ST-A embodies cutting-edge technology and thoughtful design, providing versatile and effective respiratory support. With its combination of intelligent algorithms, user-friendly features, and robust patient monitoring capabilities, it is well-positioned to enhance the quality of life for individuals with respiratory challenges.