ritetemp 401-014 manual Power Options, 8022C can run on batteries only AA Alkaline

Page 6

6 Check Unit cont.

Note: If you have an electric furnace system and the blower does not operate after installation, remove the thermostat, turn it over, and find the electric/gas heat selector jumper on the back of the control unit. Switch it to "Elect"(see Diag below).

Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the new thermostat.

7 Power Options

 

 

 

 

 

1) The 8022C can run on batteries only. (2AA Alkaline)

24VAC and MV

The batteries will last well over 1 year. If the batteries are not replaced the

thermostat will stop working.

 

 

 

 

 

2) The 8022C can run on the C wire if available.

 

24VAC ONLY

As shown in the wiring diagrams, The C wire is the other side of the 24VAC

heating transformer. If the C wire is used, the batteries are then for AC power

loss only and will last much longer. The thermostat will continue working if the

batteries die.

 

 

 

 

 

PG 9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear View of control unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12/24hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jumper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

oF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

oC

 

 

 

 

 

oC -oF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jumper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECT GAS

 

 

 

 

Circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas - Electric jumper

PG 10

Image 6
Contents Install guide 8022C U T I O N Tools LocationRemove old unit Mount the 8022CBefore you Connect Wires Optional Wire ConnectionsTo check Cool mode Install BatteriesTo check Heat mode Check UnitPower Options 8022C can run on the C wire if available8022C can run on batteries only AA Alkaline Wire Heating GAS Millivolt or 24vac WirePG 13 Note Wires marked with the dotted line are optional 8022C Features Should be changed in your blower

401-014 specifications

The Ritetemp 401-014 thermostat is designed for homeowners seeking an efficient and user-friendly temperature control solution. This programmable thermostat offers a robust range of features tailored to enhance home comfort while promoting energy savings.

At the core of the Ritetemp 401-014 is its programmable functionality. Users can set schedules that align with their daily routines, allowing the thermostat to automatically adjust heating and cooling based on predetermined times. This not only ensures that the home remains comfortable during waking hours but also conserves energy when occupants are away. With a 7-day programming capability, it allows flexibility in scheduling, accommodating varying needs throughout the week.

One of the standout technologies in the Ritetemp 401-014 is its easy-to-read LCD display. The large, backlit screen provides clear visibility of the current temperature settings and time, making it easy to monitor and adjust even in low light conditions. The interface is designed for user-friendliness, with intuitive buttons that simplify programming and adjustments.

The thermostat is compatible with various HVAC systems, including gas, oil, and electric heating systems, as well as central air conditioning units. This versatility makes it an excellent choice for a wide range of home heating and cooling setups. Additionally, the Ritetemp 401-014 features a built-in compressor protection delay, which helps to safeguard the HVAC system from potential damage caused by rapid cycling.

Energy efficiency is a critical characteristic of the Ritetemp 401-014. By utilizing programmable schedules, it allows homeowners to minimize energy expenditure while maintaining comfort levels. The device also features a battery backup system, ensuring that the settings are preserved even during power outages.

Another significant characteristic of the Ritetemp 401-014 is its ease of installation. The thermostat typically fits standard wall plates, making it a straightforward upgrade from an older unit. For tech-savvy homeowners, the thermostat is also compatible with smart home systems, providing additional control through mobile apps or voice command features.

Overall, the Ritetemp 401-014 thermostat combines simplicity, efficiency, and advanced technology, making it a reliable choice for homeowners aiming to enhance their comfort while managing energy usage effectively. Its user-friendly design, robust programming features, and compatibility with various HVAC systems make it a standout option in the realm of programmable thermostats.