ritetemp 401-014 manual Before you Connect Wires, Optional Wire Connections

Page 4

4 Before you Connect Wires

Please follow these guidelines for safe and secure wire connections.

Strip insulation 3/8 in. (9.5mm) from wire ends. Take care not to damage the labels for each wire in handling.

Connect labeled wires only to a terminal with corresponding letter. Bend the wire slightly, insert the wire under the contact plate and tighten the screw down onto the wire.

D o n o t a l l o w w i r e s t o t o u c h e a c h o t h e r o r p a r t s o n t h e r m o s t a t .

Caution W i r e s m u s t b e r o u t e d t h r o u g h t h e h o l e i n t h e b a c k p l a t e , b e lo w t h e t e r m i n a l b l o c k , o r t h e y w i l l h i t p a r t s o n t h e c o v e r .

Optional Wire Connections

Determine which step-by-step wiring diagram you should use. Make sure your wires are labeled. This may require you to find the 'other nd'e connection for each wire on your heating or air conditioning equipment and read the label there.

If you have a wire marked "C" its connection is optional. If you do connect it the thermostat will draw power from the C wire and this will extend battery life.

If you have zoned heating/cooling systems with multiple thermostats. Please refer to the website at www.ritetemp-thermostats.com for installation details or call

1-888-515-2585 for assistance.

 

 

 

PG 5

What Wires Do You Have?

From

Furnace

R

 

 

 

 

 

 

 

G

R - Single source power for heat/cool

 

 

or

 

 

From

 

 

 

 

Furnace

Note: R connects to both RC and RH using the red jumper

 

 

RH

RH or R

RH or R - HEATING POWER

C

 

 

 

RC - COOLING POWER

W

 

W

W - HEATING CONTROL

 

 

 

 

G - FAN RELAY

 

 

 

C

C - Common side of Heating Power

Go To Page 11

Go To Page 12

Y - COMPRESSOR

 

 

 

O - DAMPER OR CHANGEOVER VALVE (POWERED IN COOL)

 

 

 

 

From

Furnace

 

 

 

 

From

single

stage

 

From Furnace

 

 

And

AC unit

Y

 

heat

pump

Y

 

 

And

AC unit

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

RH

 

 

O

 

 

 

or

 

 

 

 

or

 

 

 

 

 

 

 

 

 

 

 

RH

 

 

RC

 

 

B

 

 

 

 

 

 

 

 

 

 

 

C

G

 

C

G

 

C

G

 

 

 

 

 

 

 

 

 

W

 

 

 

 

R

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

Go To Page 13

 

 

Go To Page 14

 

Go To Page 15

PG 6

 

 

 

 

 

 

 

 

 

Image 4
Contents Install guide 8022C U T I O N Tools LocationRemove old unit Mount the 8022CBefore you Connect Wires Optional Wire ConnectionsInstall Batteries To check Heat modeTo check Cool mode Check Unit8022C can run on the C wire if available Power Options8022C can run on batteries only AA Alkaline Wire Heating GAS Millivolt or 24vac WirePG 13 Note Wires marked with the dotted line are optional 8022C Features Should be changed in your blower

401-014 specifications

The Ritetemp 401-014 thermostat is designed for homeowners seeking an efficient and user-friendly temperature control solution. This programmable thermostat offers a robust range of features tailored to enhance home comfort while promoting energy savings.

At the core of the Ritetemp 401-014 is its programmable functionality. Users can set schedules that align with their daily routines, allowing the thermostat to automatically adjust heating and cooling based on predetermined times. This not only ensures that the home remains comfortable during waking hours but also conserves energy when occupants are away. With a 7-day programming capability, it allows flexibility in scheduling, accommodating varying needs throughout the week.

One of the standout technologies in the Ritetemp 401-014 is its easy-to-read LCD display. The large, backlit screen provides clear visibility of the current temperature settings and time, making it easy to monitor and adjust even in low light conditions. The interface is designed for user-friendliness, with intuitive buttons that simplify programming and adjustments.

The thermostat is compatible with various HVAC systems, including gas, oil, and electric heating systems, as well as central air conditioning units. This versatility makes it an excellent choice for a wide range of home heating and cooling setups. Additionally, the Ritetemp 401-014 features a built-in compressor protection delay, which helps to safeguard the HVAC system from potential damage caused by rapid cycling.

Energy efficiency is a critical characteristic of the Ritetemp 401-014. By utilizing programmable schedules, it allows homeowners to minimize energy expenditure while maintaining comfort levels. The device also features a battery backup system, ensuring that the settings are preserved even during power outages.

Another significant characteristic of the Ritetemp 401-014 is its ease of installation. The thermostat typically fits standard wall plates, making it a straightforward upgrade from an older unit. For tech-savvy homeowners, the thermostat is also compatible with smart home systems, providing additional control through mobile apps or voice command features.

Overall, the Ritetemp 401-014 thermostat combines simplicity, efficiency, and advanced technology, making it a reliable choice for homeowners aiming to enhance their comfort while managing energy usage effectively. Its user-friendly design, robust programming features, and compatibility with various HVAC systems make it a standout option in the realm of programmable thermostats.