Ruud AP14236 installation instructions Venting, Blower Assembly Installation

Page 12

Installing the water heater.

The water heater must be installed with the factory supplied blower assembly in place.

DANGER: Failure to install the blower assembly and properly vent the water heater to the outdoors as outlined in the Venting section of this manual will result in unsafe operation of the water heater causing bodily injury, explosion, fire or death.

To avoid the risk of fire, explosion, or asphyxiation from carbon monoxide, NEVER operate the water heater unless it is properly vented and has adequate air supply for proper operation as outlined in the Venting section of this manual.

The vent pipe must overlap a minimum of ½” on each connection. It is important that the vent pipe engages fully into any pipe fitting and be kept in that position until the adhesive has fully cured. DO NOT drill or punch holes in the plastic pipe or fittings.

NOTICE: This unit is equipped with a Flammable Vapor Sensor. Do not apply power until enough time has passed to allow the vapors from the primer and cement to dissipate.

Venting

The water heater must be vented to the outdoors as described in these instructions. DO NOT connect this water heater to

an existing vent or chimney - it must be vented separately from all other appliances.

NOTICE: This unit can be vented using only the following recommended pipe material. Use only 2- or 3-inch diameter pipe.

PVC (Schedule 40, ASTM D1785) CPVC (Schedule 40, ASTM F441) ABS (Schedule 40, ASTM D2661)

ABS (Schedule 40 DWV, Cellular Core, ASTM F891)

The fittings, other than the TERMINATION, should be equivalent to the following:

PVC (Schedule 40 DWV, ASTM D2665) CPVC (Schedule 40, ASTM F438)

ABS (Schedule 40 DWV, ASTM D2661)

The unit may be vented horizontally through a wall or vertically through the roof.

Vent pipe runs must be adequately supported along both vertical and horizontal lengths.

Maximum unsupported length is recommended to be no more than 6 feet.

It is imperative that the first hanger be located on the horizontal length immediately adjacent to the first

90-degree elbow from the vertical rise of vent pipe connected to the water heater.

The support method used should isolate the vent pipe from floor joists or other structural members to help prevent the transmission of noise and vibration.

Do not support, pin or otherwise secure the venting system in a way that restricts the normal thermal expansion and contraction of the chosen venting material.

If the water heater is being installed as a replacement for an existing power vented water heater, a thorough inspection of the existing venting system must be performed prior to any installation work.

Verify that the correct materials as detailed above have been used, and that the minimum or maximum vent length and terminal locations as detailed in this manual have been met.

Carefully inspect the entire venting system for any signs of cracks or fractures, particularly at the joints between elbows or other fittings and the straight length of vent pipe.

Check the system for signs of sagging or other stresses in the joints as a result of misalignment of any components in the system.

If any of these conditions are found, they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service.

Additional installation infor- mation for The Commonwealth of Massachusetts is located on the back page of this manual.

Rubber

Sheet Metal

Coupling

Screws

Blower

 

Assembly

 

Flue

Electrical Baffle

Connector

Blower Assembly Installation

(if not factory installed)

Connect blower assembly with the electrical connector. Attach Blower Assembly to top pan using the six (6) screws provided (See diagram to the left). Install rubber coupling (supplied in the box with water heater) on blower housing and secure it.

NOTICE: The Blower Assembly is model specific and only the blower assembly supplied should be used on this water heater.

12

Image 12
Contents Water Heaters ReferenceFor Your Records R N I N G Water increases Potential for Hot WaterPage For Installations in the State of California Installing the water heater LocationInspect Shipment Combustion and Ventilation AirCorrosive Atmospheres Typical Installation Thermal ExpansionWater Supply Connections Relief Valve To Fill the Water HeaterCondensation Leak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeBlower Assembly Installation VentingMaximum Venting information for 2 Vents Maximum Venting information for 3 VentsMaximum Altitude for ModelsMaximum Venting information for 4 Vents Models Altitude for42VP60F 700’ 42VP60PF Horizontal Vent Terminal Location Additional ConsiderationsHorizontal Vent Installation Vertical Vent InstallationVertical Vent Termination Location Cleaner-Primer and Medium Body Solvent Cement Cementing JointsWiring Connection DiagramHot and Cold Pipe Insulation Installation Insulation BlanketsDilution Air Holes During Installation of this water heater Heat TrapInstallation Checklist Water Heater LocationWater Supply Combination Potable Water and Space Heating Application House Hot water Supply to From HOT Heating Outlet on UnitFor Your Safety Read Before Operating Lighting the water heaterOperating Procedure Water Temperature SettingOperating the water heater Water Temperature Setting… Sequence of Operation… Routine Preventative Maintenance Draining the Water HeaterHousekeeping Venting System InspectionBurner Inspection Vacation and Extended Shut-Down Anode RodBefore You Call For Service… Rumbling noise Relief valveProducing popping Noise or drainingGas Valve LED Codes Replacement Parts Use only original equipment replacement partsInstructions For Placing a Parts Order Page Page If YOU Need Service

AP14236 specifications

Ruud AP14236 is a highly efficient air conditioning unit that stands out in the residential HVAC market for its remarkable performance and innovative technology. This model is specifically engineered to provide optimal cooling and heating solutions, offering homeowners comfort year-round while also emphasizing energy efficiency.

One of the key features of the Ruud AP14236 is its efficiency rating, showcased by its SEER (Seasonal Energy Efficiency Ratio) rating, which provides users with an indication of energy consumption versus cooling output. With ratings often exceeding 14, the unit is designed to reduce energy bills significantly while maintaining a comfortable indoor environment. In addition to SEER, the unit boasts an HSPF (Heating Season Performance Factor) that guarantees excellent performance during colder months.

The Ruud AP14236 utilizes advanced inverter technology that allows for variable speed operation. This technology enables the air conditioner to adjust its cooling output based on the actual temperature in the home, leading to lower energy consumption while ensuring that the desired climate is reached swiftly and efficiently. This feature not only enhances comfort but also prolongs the lifespan of the unit, as it does not require the constant on-off cycling seen in traditional systems.

Equipped with an enhanced filtration system, the Ruud AP14236 significantly improves indoor air quality by capturing dust, allergens, and other particulates. This characteristic is particularly advantageous for those with allergies or respiratory conditions, as it creates a healthier living environment.

Durability is another hallmark of the Ruud AP14236, featuring robust construction materials designed to withstand the rigors of varied weather conditions. The unit's cabinet is often galvanized and treated to resist rust, ensuring longevity and reducing maintenance issues.

Noise reduction is also a primary focus in the design of Ruud AP14236. The unit operates quietly, allowing for comfortable living spaces without the disruptive sounds commonly associated with air conditioning systems. This is achieved through sound-dampening technology and acoustic insulation.

In summary, the Ruud AP14236 is engineered for energy efficiency, versatility, durability, and quiet operation. Homeowners seeking a reliable and efficient air conditioning solution will find that this unit meets their needs while providing year-round comfort and improved air quality.