Ruud AP14236 installation instructions Gas Valve LED Codes

Page 32

Gas Valve LED Codes

LED Status

Problem

 

Solution

○ ○ ▼ A B C

 

1.

Check that the earth ground connection is properly

● ○ ○ ● ○ ○

An open earth ground circuit to the

2.

connected.

 

ignition system.

Check that the ground conductor on the water

 

 

 

heater is properly connected.

○ ○ ▼ A B C

 

1.

Check proper connection of line

● ○ ● ○ ● ○

Wiring error or a high resistance to

2.

neutral and hot wires.

 

earth ground.

Check that the water heater is securely connected

 

 

 

to earth ground.

○ ○ ▼ A B C

Pressure switch remained closed

1.

Pressure switch wiring is incorrect.

● ○ ● ○ ○ ○

longer

2.

Replace pressure switch.

than 5 seconds after the call for

 

heat began.

 

 

○ ○ ▼ A B C

Pressure switch remained open lon-

1.

Pressure switch wiring is incorrect.

● ○ ● ○ ○ ●

thanger 5 seconds after the combustion

2.

Pressure switch tubing is not connected correctly.

 

blower was energized.

3. Air intake or exhaust obstructed.

○ ○ ▼ A B C

Error in the hot surface ignitor cir-

1.

Check that all wiring is correct and secure.

● ○ ● ○ ● ●

cuit.

2.

Replace hot surface ignitor.

○ ○ ▼ A B C

System in lockout.

1.

Gas supply is off or too low to operate.

● ○ ○ ● ● ○

 

2.

Hot surface ignitor not positioned

 

 

 

correctly.

 

 

3.

Low voltage to the water heater.

 

 

4.

Electric polarity to unit is incorrect - test and cor-

 

 

 

rect.

 

 

5.

Combustion shut-off device tripped, contact ser-

 

 

 

vice agency.

○ ○ ▼ A B C

 

1.

Turn power to the water heater off for 10 seconds

● ○ ○ ○ ● ●

Problem in the gas valve driver cir-

 

and then back on.

 

cuit.

2.

Replace gas control valve.

 

 

○ ○ ▼ A B C

 

1.

Turn power to the water heater off for 10 seconds

● ○ ● ● ● ○

Problem with the internal circuit.

 

and then back on.

 

 

2.

Replace gas control valve.

○ ○ ▼ A B C

 

1.

Turn power to the water heater off for 10 seconds

● ● ● ● ● ●

Problem with the internal circuit.

 

and then back on.

 

 

2.

Replace gas control valve.

○ ○ ▼ A B C

Flame signal sensed out of

1.

Replace gas control valve.

● ○ ○ ○ ● ○

proper sequence.

 

 

○ ○ ▼ A B C

ECO activated.

1.

Replace gas control valve.

● ○ ○ ● ● ●

 

 

○ ○ ▼ A B C

One of the temperature adjust

1.

Press and release each of the buttons once.

● ○ ● ● ○ ○

buttons stuck closed.

2.

Replace gas control valve.

○ ○ ▼ A B C

Water temperature sensor is either open

1.

Check that all wiring is correct and secure.

● ○ ● ● ○ ●

or short circuited.

2.

Replace gas control valve.

○ ○ ▼ A B C

 

1.

Check for correct wiring to FV sensor.

● ○ ○ ● ○ ●

Unit shuts down.

2.

Check for open circuits to FV sensor.

 

 

3.

Replace FV sensor.

○ ○ ▼ A B C

 

1.

FV sensor detected presence of flammable vapors.

● ○ ○ ○ ○ ●

Unit shuts down and in lockout.

2.

Contact a service agency.

 

 

 

 

CAUTION: Make certain power to water heater is “OFF” before removing protective cover FOR ANY REASON.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. VERIFY PROPER OPERATION AFTER SERVICING.

CAUTION: For your safety DO NOT attempt repair of gas piping, remote control, burners, vent connectors or other safety devices. Refer repairs to qualified service personnel.

32

Image 32
Contents Water Heaters ReferenceFor Your Records R N I N G Water increases Potential for Hot WaterPage For Installations in the State of California Installing the water heater LocationCorrosive Atmospheres Inspect ShipmentCombustion and Ventilation Air Water Supply Connections Typical InstallationThermal Expansion Condensation Relief ValveTo Fill the Water Heater Leak Testing Pressure Testing the Gas Supply SystemGas Supply High AltitudeBlower Assembly Installation VentingMaximum Venting information for 2 Vents Maximum Venting information for 3 VentsMaximum Altitude for Models42VP60F 700’ 42VP60PF Maximum Venting information for 4 VentsModels Altitude for Horizontal Vent Terminal Location Additional ConsiderationsVertical Vent Termination Location Horizontal Vent InstallationVertical Vent Installation Cleaner-Primer and Medium Body Solvent Cement Cementing JointsWiring Connection DiagramDilution Air Holes Hot and Cold Pipe Insulation InstallationInsulation Blankets During Installation of this water heater Heat TrapWater Supply Installation ChecklistWater Heater Location Combination Potable Water and Space Heating Application House Hot water Supply to From HOT Heating Outlet on UnitFor Your Safety Read Before Operating Lighting the water heaterOperating the water heater Operating ProcedureWater Temperature Setting Water Temperature Setting… Sequence of Operation… Routine Preventative Maintenance Draining the Water HeaterBurner Inspection HousekeepingVenting System Inspection Vacation and Extended Shut-Down Anode RodBefore You Call For Service… Rumbling noise Relief valveProducing popping Noise or drainingGas Valve LED Codes Instructions For Placing a Parts Order Replacement PartsUse only original equipment replacement parts Page Page If YOU Need Service

AP14236 specifications

Ruud AP14236 is a highly efficient air conditioning unit that stands out in the residential HVAC market for its remarkable performance and innovative technology. This model is specifically engineered to provide optimal cooling and heating solutions, offering homeowners comfort year-round while also emphasizing energy efficiency.

One of the key features of the Ruud AP14236 is its efficiency rating, showcased by its SEER (Seasonal Energy Efficiency Ratio) rating, which provides users with an indication of energy consumption versus cooling output. With ratings often exceeding 14, the unit is designed to reduce energy bills significantly while maintaining a comfortable indoor environment. In addition to SEER, the unit boasts an HSPF (Heating Season Performance Factor) that guarantees excellent performance during colder months.

The Ruud AP14236 utilizes advanced inverter technology that allows for variable speed operation. This technology enables the air conditioner to adjust its cooling output based on the actual temperature in the home, leading to lower energy consumption while ensuring that the desired climate is reached swiftly and efficiently. This feature not only enhances comfort but also prolongs the lifespan of the unit, as it does not require the constant on-off cycling seen in traditional systems.

Equipped with an enhanced filtration system, the Ruud AP14236 significantly improves indoor air quality by capturing dust, allergens, and other particulates. This characteristic is particularly advantageous for those with allergies or respiratory conditions, as it creates a healthier living environment.

Durability is another hallmark of the Ruud AP14236, featuring robust construction materials designed to withstand the rigors of varied weather conditions. The unit's cabinet is often galvanized and treated to resist rust, ensuring longevity and reducing maintenance issues.

Noise reduction is also a primary focus in the design of Ruud AP14236. The unit operates quietly, allowing for comfortable living spaces without the disruptive sounds commonly associated with air conditioning systems. This is achieved through sound-dampening technology and acoustic insulation.

In summary, the Ruud AP14236 is engineered for energy efficiency, versatility, durability, and quiet operation. Homeowners seeking a reliable and efficient air conditioning solution will find that this unit meets their needs while providing year-round comfort and improved air quality.