Ruud AP14236 installation instructions

Page 5

DANGER!

liquefied petroleum (LP Propane or butane) and Natural gas models

LP and Natural gas have an odorant added to aid in detecting a gas leak. Some people may not physically be able to smell or recognize this odorant. If you are unsure or unfamiliar with the smell of LP or natural gas, ask the gas supplier. Other conditions, such as “odorant fade”, which causes the odorant to diminish in intensity, can also hide or camouflage a gas leak.

Water heaters utilizing LP gas are different from natural gas models. A natural gas water heater will not function safely on LP gas and vice versa.

No attempt should ever be made to convert the water heater from natural gas to LP gas. To avoid possible equipment damage, personal injury or fire, do not connect the water heater to a fuel type not in accordance with the unit data plate. LP for LP units. Natural gas for natural gas units. These units are not certified for any other fuel type.

LP appliances should not be installed below grade (for example, in a basement) if such installation is prohibited by federal, state and/or local laws, rules, regulations or customs.

LP gas must be used with great caution. It is heavier than air and will collect first in lower areas making it hard to detect at nose level.

Before attempting to light the water heater, make sure to look and smell for gas leaks. Use a soapy solution to check all gas fittings and connections. Bubbling at a connection indicates a leak that must be corrected. When smelling to detect a gas leak, be sure to sniff near the floor also.

Gas detectors are recommended in LP & natural gas applications and their installation should be in accordance with the detector manufacturer’s recommendations and/or local laws, rules, regulations or customs.

It is recommended that more than one method, such as soapy solution, gas detectors, etc., be used to detect leaks in gas applications.

!DANGER: If a gas leak is present or suspected:

Do not attempt to find the cause yourself.

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Leave the house immediately and make sure your family and pets leave also.

Leave the doors open for ventilation and contact the gas supplier, a qualified service agency or the fire department.

Stay away from the house (or building) until the service call has been made, the leak is corrected and a qualified agency has determined the area to be safe.

5

Image 5
Contents Reference Water HeatersFor Your Records R N I N G Potential for Hot Water Water increasesPage For Installations in the State of California Location Installing the water heaterCorrosive Atmospheres Inspect ShipmentCombustion and Ventilation Air Water Supply Connections Typical InstallationThermal Expansion Condensation Relief ValveTo Fill the Water Heater Pressure Testing the Gas Supply System Leak TestingGas Supply High AltitudeVenting Blower Assembly InstallationMaximum Venting information for 3 Vents Maximum Venting information for 2 VentsMaximum Altitude for Models42VP60F 700’ 42VP60PF Maximum Venting information for 4 VentsModels Altitude for Additional Considerations Horizontal Vent Terminal LocationVertical Vent Termination Location Horizontal Vent InstallationVertical Vent Installation Cementing Joints Cleaner-Primer and Medium Body Solvent CementConnection Diagram WiringDilution Air Holes Hot and Cold Pipe Insulation InstallationInsulation Blankets Heat Trap During Installation of this water heaterWater Supply Installation ChecklistWater Heater Location House Hot water Supply to From HOT Heating Outlet on Unit Combination Potable Water and Space Heating ApplicationLighting the water heater For Your Safety Read Before OperatingOperating the water heater Operating ProcedureWater Temperature Setting Water Temperature Setting… Sequence of Operation… Draining the Water Heater Routine Preventative MaintenanceBurner Inspection HousekeepingVenting System Inspection Anode Rod Vacation and Extended Shut-DownBefore You Call For Service… Relief valve Rumbling noiseProducing popping Noise or drainingGas Valve LED Codes Instructions For Placing a Parts Order Replacement PartsUse only original equipment replacement parts Page Page If YOU Need Service

AP14236 specifications

Ruud AP14236 is a highly efficient air conditioning unit that stands out in the residential HVAC market for its remarkable performance and innovative technology. This model is specifically engineered to provide optimal cooling and heating solutions, offering homeowners comfort year-round while also emphasizing energy efficiency.

One of the key features of the Ruud AP14236 is its efficiency rating, showcased by its SEER (Seasonal Energy Efficiency Ratio) rating, which provides users with an indication of energy consumption versus cooling output. With ratings often exceeding 14, the unit is designed to reduce energy bills significantly while maintaining a comfortable indoor environment. In addition to SEER, the unit boasts an HSPF (Heating Season Performance Factor) that guarantees excellent performance during colder months.

The Ruud AP14236 utilizes advanced inverter technology that allows for variable speed operation. This technology enables the air conditioner to adjust its cooling output based on the actual temperature in the home, leading to lower energy consumption while ensuring that the desired climate is reached swiftly and efficiently. This feature not only enhances comfort but also prolongs the lifespan of the unit, as it does not require the constant on-off cycling seen in traditional systems.

Equipped with an enhanced filtration system, the Ruud AP14236 significantly improves indoor air quality by capturing dust, allergens, and other particulates. This characteristic is particularly advantageous for those with allergies or respiratory conditions, as it creates a healthier living environment.

Durability is another hallmark of the Ruud AP14236, featuring robust construction materials designed to withstand the rigors of varied weather conditions. The unit's cabinet is often galvanized and treated to resist rust, ensuring longevity and reducing maintenance issues.

Noise reduction is also a primary focus in the design of Ruud AP14236. The unit operates quietly, allowing for comfortable living spaces without the disruptive sounds commonly associated with air conditioning systems. This is achieved through sound-dampening technology and acoustic insulation.

In summary, the Ruud AP14236 is engineered for energy efficiency, versatility, durability, and quiet operation. Homeowners seeking a reliable and efficient air conditioning solution will find that this unit meets their needs while providing year-round comfort and improved air quality.