Ruud AP14236 installation instructions For Your Records

Page 2

Safety Information

Safety Precautions. . . . 3–6 LP Gas Models . . . . . . 5

Installation Instructions

Location. . . . . . . . . 7 Water Supply Connections. . 9 Gas Supply. . . . . . . . 11 Venting. . . . . . . . 12-16 Wiring Diagram. . . . . . 18 Pipe Insulation. . . . . . .19 Heat Traps . . . . . . . . 20 Installation Checklist. . . . 21 Potable/Space Heating . . . 22

Operating Instructions

Lighting Instructions. . . . 23 Water Temperature . . . 24, 25

Care and Cleaning

Draining. . . . . . . . . 27 Maintenance. . . . . . . 27 Vent System Inspection. . . 28 Burner Inspection . . . . . 28 Extended Shut-Down. . . .29

Troubleshooting Tips

Before You Call

For Service. . . . . . 30-32

FOR YOUR RECORDS

Write the model and serial numbers here:

#

#

You can find them on a label on the appliance.

Staple sales slip or cancelled check here.

Proof of the original purchase date is needed to obtain service under the warranty.

READ THIS MANUAL

Inside you will find many helpful hints on how to use and maintain your water heater properly. A little preventive care on your part can save you time and money over the life of your water heater.

You’ll find many answers to common problems in the Troubleshooting Guide. If you review the chart of Troubleshooting Tips first, you may not need to call for service.

READ THE SAFETY INFORMATION

Your safety and the safety of others are very important. There are many important safety messages in this manual and on your appliance. Always read and obey all safety messages.

This is the safety alert symbol. Recognize this symbol ! as an indication of Important Safety Information!

This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and either the word “DANGER”, “WARNING”, “CAUTION” or “NOTICE”.

These words mean:

 

! DANGER

An imminently hazardous situation

 

that will result in death or serious

 

injury.

Customer Service

Parts List. . . . . . . . . 33 If You Need Service . . . . 36

!WARNING

!CAUTION

Notice:

A potentially hazardous situation that could result in death or serious injury and/or damage to property.

A potentially hazardous situation that may result in minor or moderate injury.

Attention is called to observe a specified procedure or maintain a specific condition.

2

Image 2
Contents Water Heaters ReferenceFor Your Records R N I N G Water increases Potential for Hot WaterPage For Installations in the State of California Installing the water heater LocationCorrosive Atmospheres Inspect ShipmentCombustion and Ventilation Air Water Supply Connections Typical InstallationThermal Expansion Condensation Relief ValveTo Fill the Water Heater Gas Supply Leak TestingPressure Testing the Gas Supply System High AltitudeBlower Assembly Installation VentingMaximum Maximum Venting information for 2 VentsMaximum Venting information for 3 Vents Altitude for Models42VP60F 700’ 42VP60PF Maximum Venting information for 4 VentsModels Altitude for Horizontal Vent Terminal Location Additional ConsiderationsVertical Vent Termination Location Horizontal Vent InstallationVertical Vent Installation Cleaner-Primer and Medium Body Solvent Cement Cementing JointsWiring Connection DiagramDilution Air Holes Hot and Cold Pipe Insulation InstallationInsulation Blankets During Installation of this water heater Heat TrapWater Supply Installation ChecklistWater Heater Location Combination Potable Water and Space Heating Application House Hot water Supply to From HOT Heating Outlet on UnitFor Your Safety Read Before Operating Lighting the water heaterOperating the water heater Operating ProcedureWater Temperature Setting Water Temperature Setting… Sequence of Operation… Routine Preventative Maintenance Draining the Water HeaterBurner Inspection HousekeepingVenting System Inspection Vacation and Extended Shut-Down Anode RodBefore You Call For Service… Producing popping Rumbling noiseRelief valve Noise or drainingGas Valve LED Codes Instructions For Placing a Parts Order Replacement PartsUse only original equipment replacement parts Page Page If YOU Need Service

AP14236 specifications

Ruud AP14236 is a highly efficient air conditioning unit that stands out in the residential HVAC market for its remarkable performance and innovative technology. This model is specifically engineered to provide optimal cooling and heating solutions, offering homeowners comfort year-round while also emphasizing energy efficiency.

One of the key features of the Ruud AP14236 is its efficiency rating, showcased by its SEER (Seasonal Energy Efficiency Ratio) rating, which provides users with an indication of energy consumption versus cooling output. With ratings often exceeding 14, the unit is designed to reduce energy bills significantly while maintaining a comfortable indoor environment. In addition to SEER, the unit boasts an HSPF (Heating Season Performance Factor) that guarantees excellent performance during colder months.

The Ruud AP14236 utilizes advanced inverter technology that allows for variable speed operation. This technology enables the air conditioner to adjust its cooling output based on the actual temperature in the home, leading to lower energy consumption while ensuring that the desired climate is reached swiftly and efficiently. This feature not only enhances comfort but also prolongs the lifespan of the unit, as it does not require the constant on-off cycling seen in traditional systems.

Equipped with an enhanced filtration system, the Ruud AP14236 significantly improves indoor air quality by capturing dust, allergens, and other particulates. This characteristic is particularly advantageous for those with allergies or respiratory conditions, as it creates a healthier living environment.

Durability is another hallmark of the Ruud AP14236, featuring robust construction materials designed to withstand the rigors of varied weather conditions. The unit's cabinet is often galvanized and treated to resist rust, ensuring longevity and reducing maintenance issues.

Noise reduction is also a primary focus in the design of Ruud AP14236. The unit operates quietly, allowing for comfortable living spaces without the disruptive sounds commonly associated with air conditioning systems. This is achieved through sound-dampening technology and acoustic insulation.

In summary, the Ruud AP14236 is engineered for energy efficiency, versatility, durability, and quiet operation. Homeowners seeking a reliable and efficient air conditioning solution will find that this unit meets their needs while providing year-round comfort and improved air quality.