Sunlife Enterprises DM180 Optional GAS Heat, GAS Heat Application Data, GAS Piping, Pipe Sizing

Page 14

356214-XIM-A-0108

OPTIONAL GAS HEAT

These gas-fired heaters have aluminized-steel or optional stainless steel, tubular heat exchangers with spark ignition with proven pilot.

TABLE 4: GAS HEAT APPLICATION DATA

All gas heaters are shipped from the factory equipped for natural gas use, but can be field converted to L.P./ Propane with Kit Model # 1NP0418. See Gas Heat Application Data Table.

0 To

 

2,000 To

Output Capacity (Mbh)

 

 

Temp.

 

 

 

 

 

2,000 Feet

4,500 Feet

0 To

2,000 To

 

Gas

Rise ºF

2,000 Feet

4,500 Feet

Available

Above

 

Above

Rate

 

At

 

Above

Above

on Models

 

Sea Level

Sea Level

(Ft./Hr.)

Full Input

Sea Level

Sea Level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max.

 

Min.

Max.

Min.

Max.

Max.

 

 

Min.

 

Max.

 

 

 

 

 

 

 

 

 

 

 

 

300

 

150

270

135

240

213

15, 20 & 25 Ton

279

20

 

50

 

 

 

 

 

 

 

 

 

 

 

 

350

 

175

320

160

280

241

25 Ton

326

30

 

60

 

 

 

 

 

 

 

 

 

 

 

 

GAS PIPING

Proper sizing of gas piping depends on the cubic feet per hour of gas flow required, specific gravity of the gas and the length of run. "National Fuel Gas Code" Z223.1 (in U.S.A.) or the current Gas Installation Codes CSA- B149.1 (in Canada) should be followed in all cases unless superseded by local codes or gas utility require- ments. Refer to the Pipe Sizing Table 5.

The heating value of the gas may differ with locality. The value should be checked with the local gas utility.

NOTE: There may be a local gas utility requirement specifying a minimum diameter for gas piping. All units require a one-inch pipe connection at the entrance fitting.

TABLE 5: PIPE SIZING

Length in Feet

Nominal Iron Pipe Size

 

 

1 in.

1-1/4 in.

 

 

 

 

10

520

1,050

 

 

 

20

350

730

 

 

 

30

285

590

 

 

 

40

245

500

 

 

 

50

215

440

 

 

 

60

195

400

 

 

 

70

180

370

 

 

 

80

170

350

 

 

 

90

160

320

 

 

 

100

150

305

 

 

 

Maximum capacity of pipe in cubic feet of gas per hour. (Based upon a pressure drop of 0.3 inch water column and 0.6 specific gravity gas).

GAS CONNECTION

The gas supply line can be routed through the knock- outs located on the front of the unit or through the opening provided in the unit's base. Refer to the Dimensions and Clearances Figure 13 to locate these access openings. Typical supply piping arrangements are shown in the figures on page 15. All shaded items are field-supplied.

If gas supply line is routed through the unit's base ensure that the burner assembly can be removed for maintenance without disturbing the supply line. The supply piping and fittings must lie below the bottom gas manifold to avoid interference with the burner assem- bly.

Two grommets are shipped in the blower compartment (in parts bag taped to the blower housing) of every unit with gas heat and should be used in the knockouts when the gas piping penetrates the front of the unit.

After the gas supply piping has been installed, the bot- tom opening in the unit should be sealed to prevent water from leaking into the building.

Gas piping recommendations:

1.A drip leg and a ground joint union must be installed in the gas piping.

2.When required by local codes, a manual shut-off valve may have to be installed outside of the unit.

3.Use wrought iron or steel pipe for all gas lines. Pipe compound should be applied sparingly to male threads only.

14

Johnson Controls Unitary Products

Image 14
Contents Installation Table of Contents List of Figures List of TablesInspection Safety ConsiderationsGeneral ReferenceRenewal Parts ApprovalsProduct Nomenclature Ton Sunline & Magnum & MagnaDRY Model Number NomenclatureLimitations InstallationInstallation Safety Information Unit Application Data LocationRigging and Handling ClearancesDuctwork Fixed Outdoor AIR Intake DamperService Access FiltersField Wiring DM ELECTRIC/ELECTRIC and GAS/ Electric Units Thermostat Power and Control WiringControl Wire Sizes Electric Heat Application Data Optional Electric HeatGAS Piping Optional GAS HeatGAS Heat Application Data Pipe SizingExternal Supply Connection External SHUT-OFF Vent and Combustion AIR Hoods Vent and Combustion AIR HoodOptional Power EXHAUST/BAROMETRIC Relief Damper Rain Hood Enthalpy Setpoint Adjustment Four and SIX Point Loads Physical Data ModelsDM Electrical Data -WITHOUT Powered Convenience Outlet SizeDM Electrical Data -WITH Powered Convenience Outlet Front View Rear View Dimensions Unit Clearances and Rain Hood Dimensions 15, 20 & 25 TON Altitude Correction Factors AIR Temp Altitude MeterALTITUDE/TEMPERATURE Conversion Factor High Static Drive CFM 80 m3/s 30 m3/s 10 m3/s 40 m3/s 1030 378 321 258 199 134 1070 417 361 299 240 XIM-A-0108 DM300 Unit Downflow Duct Connections CFM Blower Motor and Drive Data Power Exhaust PerformanceStatic RESISTANCES1 Phasing Checking AIR Supply CFMIWG Drop Pressure Nominal CFM Thousands Supply AIRCooling Sequence of Operation OperationSequence of Operations Overview LOW-PRESSURE Limit Switch Compressor Protection Safety ControlsReset Flash CodesHeat Anticipator Setpoints Heating Operation ErrorsLimit Control Setting Electric Heat Anticipator SetpointsGAS Heating Operation Errors GAS Valve PipingGAS Valve START-UP Cooling PRE-START Check List START-UP GAS HeatShut Down POST-START Check List GASBurner Instructions Manifold GAS Pressure AdjustmentBurner AIR Shutter Adjustment Checking GAS InputCooling Troubleshooting Guide TroubleshootingAdjustment of Temperature Rise GAS Rate Cubic Feet PER HourXIM-A-0108 XIM-A-0108 XIM-A-0108 XIM-A-0108 GAS Heat Troubleshooting Guide XIM-A-0108 Unit Flash Codes Unit Control Board Flash Codes Unit Control BoardUnit Control Board Option Setup Option Byte SetupXIM-A-0108 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK

DM300, DM240, DM180 specifications

Sunlife Enterprises has made significant strides in the competitive market of digital management tools with their innovative lineup of products: the DM240, DM300, and DM180. Each of these devices has been engineered to cater to specific operational needs while sharing a common foundation of advanced technology, versatility, and user-centric design.

The DM240 is an entry-level model that caters to small businesses looking for an efficient digital management solution without the hefty price tag. With a compact design and intuitive user interface, the DM240 allows for seamless integration into various work environments. Key features include a high-resolution touchscreen display, which facilitates easy navigation and quick access to essential functions. The device supports wireless connectivity options, ensuring users can manage tasks from anywhere within their operating environment. The energy-efficient design of the DM240 also promotes sustainability without compromising performance.

Moving up the line, the DM300 offers enhanced capabilities for medium-sized enterprises. This model is powered by advanced processing technology, allowing for faster data handling and superior multitasking. The DM300 features expanded memory and storage options, ensuring that users can manage larger datasets effortlessly. Additionally, with built-in advanced security features like biometric authentication and encrypted data storage, businesses can ensure that sensitive information remains protected. The intuitive software interface of the DM300 is designed for ease of use while providing advanced analytics tools to enable users to make data-driven decisions.

At the top of the range is the DM180, a sophisticated solution tailored to large organizations with complex digital management needs. The DM180 showcases a state-of-the-art design with high-performance computing capabilities. It features an expansive multi-touch display, allowing multiple users to interact simultaneously, facilitating collaboration and teamwork. The DM180 is equipped with cloud integration options, promoting real-time data access and sharing among teams, regardless of location. Its scalability ensures that businesses can adapt the system to accommodate growth without compromising functionality. Moreover, it offers comprehensive reporting and analytics tools, empowering organizations to gain valuable insights into their operations.

In summary, Sunlife Enterprises’ DM240, DM300, and DM180 models stand out for their unique features designed to meet the evolving needs of businesses. With a focus on user experience, performance, and security, these devices are poised to help organizations enhance productivity and drive innovation in the digital management landscape.