Sunlife Enterprises DM300, DM240, DM180 Static RESISTANCES1, Power Exhaust Performance

Page 33

356214-XIM-A-0108

TABLE 16: STATIC RESISTANCES1

 

 

 

 

 

 

RESISTANCE, Pa/IWG

 

 

 

DESCRIPTION

 

 

 

 

 

 

m3/s/CFM

 

 

 

 

 

 

 

MODEL 180

 

 

MODEL 240

 

 

MODEL 300

 

 

 

2.1/4500

2.8/6000

 

3.4/7200

2.8/6000

3.8/8000

 

4.4/9400

3.78/8000

4.25/9000

4.72/10000

WET COIL

 

24.8/0.1

24.8/0.1

 

24.8/0.1

24.8/0.1

24.8/0.1

 

24.8/0.1

25/0.1

25/0.1

25/0.1

GAS HEAT

 

24.8/0.1

24.8/0.1

 

24.8/0.1

24.8/0.1

24.8/0.1

 

24.8/0.1

25/0.1

25/0.1

25/0.1

 

18 KW

24.8/0.1

24.8/0.1

 

24.8/0.1

24.8/0.1

24.8/0.1

 

24.8/0.1

25/0.1

25/0.1

25/0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HEAT OPTIONS

36 KW

24.8/0.1

50.0/0.2

 

74.4/0.3

24.8/0.1

50.0/0.2

 

74.4/0.3

25/0.1

50/0.2

75/0.3

 

 

 

 

 

 

 

 

 

 

 

 

54 KW

50.0/0.2

74.4/0.3

 

99.2/0.4

50.0/0.2

74.4/0.3

 

99.2/0.4

50/0.2

75/0.3

100/0.4

 

 

 

 

72 KW

50.0/0.2

99.2/0.4

 

149.0/0.6

50.0/0.2

99.2/0.4

 

149.0/0.6

50/0.2

100/0.4

150/0.6

 

 

 

 

 

 

 

 

 

 

 

 

 

ECONOMIZER OPTION

 

24.8/0.1

24.8/0.1

 

24.8/0.1

24.8/0.1

24.8/0.1

 

24.8/0.1

25/0.1

25/0.1

25/0.1

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL DUCT CONNECTIONS

50.0/0.2

74.4/0.3

 

124.0/0.5

50.0/0.2

74.4/0.3

 

124.0/0.5

50/0.2

75/0.3

125/0.5

1.Deduct these resistance values from the available external static pressures shown in the respective Blower Performance Table except for Horizontal Duct Connections.

Add these values due to less airflow resistance.

TABLE 17: POWER EXHAUST PERFORMANCE

MOTOR

 

 

 

STATIC RESISTANCE OF RETURN DUCTWORK, IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.2

0.3

 

 

0.4

0.5

 

 

0.6

SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CFM

 

KW

CFM

 

KW

CFM

 

KW

CFM

 

KW

CFM

 

KW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIGH*

5250

 

0.83

4500

 

0.85

4200

 

0.88

3750

 

0.93

3000

 

0.99

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MEDIUM

4900

 

0.77

3900

 

0.79

3500

 

0.82

2900

 

0.85

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LOW

4400

 

0.72

3700

 

0.74

3000

 

0.78

-

 

-

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Factory Setting

Power Exhaust motor is a 3/4 HP, PSC type with sleeve bearings, a 48 frame and inherent protection.

TABLE 18: BLOWER MOTOR AND DRIVE DATA

 

 

 

 

MOTOR2

 

ADJUSTABLE MOTOR PULLEY3

FIXED BLOWER PULLEY

 

BELT

 

MODEL

 

BLOWER

 

 

(NOTCHED)

 

DRIVE1

 

 

 

 

 

 

 

 

 

 

SIZE

RANGE

 

 

EFF.

DESIG-

PITCH

BORE

DESIG-

PITCH

BORE

DESIG-

PITCH

 

 

 

(RPM)

kW/HP

FRAME

DIA.

DIA.

LENGTH

QTY.

 

 

 

 

 

(%)

NATION

(mm/IN.)

(mm/IN.)

NATION

(mm/IN.)

(mm/IN.)

NATION

(mm/IN.)

 

180

High

1030/1240

3.7/5.0

184 T

83

1VP62

109-135

29/1-1/8

BK75

175/6.9

25/1

BX68

1773/69.8

1

Static

4.3-5.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

High

895-1080

5.6/7.5

213 T

87

1VP75

140-165

35/1-3/8

BK100

239/9.4

30/1-3/164

BX81

2103/82.8

1

Static

5.5-6.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

300

High

950/1130

7.5/10

254 T

89

1LVP58

157-188

A2

1B5V94

241 (9.5)

B

5VX840

2134/84

1

Static

B70A

(6.2-7.4)

Bushing

Bushing

 

 

 

 

 

 

 

 

 

 

1.All 50 Hz DM180-300 models come standard with factory filtered High Static Drive.

2.All motors have a nominal speed of 1450 RPM, a 1.15 service factor and a solid base. They can operate to the limit of their service factor because they are located in the moving air, upstream of any heating device.

3.Do NOT close this pulley below 1 turn open.

4.Requires bushing (included in kit).

Johnson Controls Unitary Products

33

Image 33
Contents Installation Table of Contents List of Tables List of FiguresGeneral Safety ConsiderationsInspection ReferenceApprovals Renewal PartsTon Sunline & Magnum & MagnaDRY Model Number Nomenclature Product NomenclatureInstallation Installation Safety InformationLimitations Location Unit Application DataClearances Rigging and HandlingFixed Outdoor AIR Intake Damper DuctworkFilters Service AccessField Wiring DM ELECTRIC/ELECTRIC and GAS/ Electric Units Control Wire Sizes Power and Control WiringThermostat Electric Heat Application Data Optional Electric HeatGAS Heat Application Data Optional GAS HeatGAS Piping Pipe SizingExternal Supply Connection External SHUT-OFF Vent and Combustion AIR Hood Vent and Combustion AIR HoodsOptional Power EXHAUST/BAROMETRIC Relief Damper Rain Hood Enthalpy Setpoint Adjustment Four and SIX Point Loads Models Physical DataSize DM Electrical Data -WITHOUT Powered Convenience OutletDM Electrical Data -WITH Powered Convenience Outlet Front View Rear View Dimensions Unit Clearances and Rain Hood Dimensions 15, 20 & 25 TON AIR Temp Altitude Meter Altitude Correction FactorsALTITUDE/TEMPERATURE Conversion Factor High Static Drive CFM 80 m3/s 30 m3/s 10 m3/s 40 m3/s 1030 378 321 258 199 134 1070 417 361 299 240 XIM-A-0108 DM300 Unit Downflow Duct Connections CFM Power Exhaust Performance Static RESISTANCES1Blower Motor and Drive Data Checking AIR Supply CFM PhasingDrop Pressure Nominal CFM Thousands Supply AIR IWGOperation Sequence of Operations OverviewCooling Sequence of Operation LOW-PRESSURE Limit Switch Reset Safety ControlsCompressor Protection Flash CodesLimit Control Setting Heating Operation ErrorsHeat Anticipator Setpoints Electric Heat Anticipator SetpointsGAS Valve Piping GAS Heating Operation ErrorsGAS Valve START-UP Cooling Shut Down START-UP GAS HeatPRE-START Check List POST-START Check List GASBurner AIR Shutter Adjustment Manifold GAS Pressure AdjustmentBurner Instructions Checking GAS InputAdjustment of Temperature Rise TroubleshootingCooling Troubleshooting Guide GAS Rate Cubic Feet PER HourXIM-A-0108 XIM-A-0108 XIM-A-0108 XIM-A-0108 GAS Heat Troubleshooting Guide XIM-A-0108 Unit Flash Codes Unit Control Board Unit Control Board Flash CodesOption Byte Setup Unit Control Board Option SetupXIM-A-0108 Johnson Controls Unitary Products Johnson Controls Unitary Products York Drive Norman, OK

DM300, DM240, DM180 specifications

Sunlife Enterprises has made significant strides in the competitive market of digital management tools with their innovative lineup of products: the DM240, DM300, and DM180. Each of these devices has been engineered to cater to specific operational needs while sharing a common foundation of advanced technology, versatility, and user-centric design.

The DM240 is an entry-level model that caters to small businesses looking for an efficient digital management solution without the hefty price tag. With a compact design and intuitive user interface, the DM240 allows for seamless integration into various work environments. Key features include a high-resolution touchscreen display, which facilitates easy navigation and quick access to essential functions. The device supports wireless connectivity options, ensuring users can manage tasks from anywhere within their operating environment. The energy-efficient design of the DM240 also promotes sustainability without compromising performance.

Moving up the line, the DM300 offers enhanced capabilities for medium-sized enterprises. This model is powered by advanced processing technology, allowing for faster data handling and superior multitasking. The DM300 features expanded memory and storage options, ensuring that users can manage larger datasets effortlessly. Additionally, with built-in advanced security features like biometric authentication and encrypted data storage, businesses can ensure that sensitive information remains protected. The intuitive software interface of the DM300 is designed for ease of use while providing advanced analytics tools to enable users to make data-driven decisions.

At the top of the range is the DM180, a sophisticated solution tailored to large organizations with complex digital management needs. The DM180 showcases a state-of-the-art design with high-performance computing capabilities. It features an expansive multi-touch display, allowing multiple users to interact simultaneously, facilitating collaboration and teamwork. The DM180 is equipped with cloud integration options, promoting real-time data access and sharing among teams, regardless of location. Its scalability ensures that businesses can adapt the system to accommodate growth without compromising functionality. Moreover, it offers comprehensive reporting and analytics tools, empowering organizations to gain valuable insights into their operations.

In summary, Sunlife Enterprises’ DM240, DM300, and DM180 models stand out for their unique features designed to meet the evolving needs of businesses. With a focus on user experience, performance, and security, these devices are poised to help organizations enhance productivity and drive innovation in the digital management landscape.