Windsor SCEOX326, SCEX326, 10052340, 10052310 KEY Switch, Emergency SHUT-OFF Switch, Brush Switch

Page 13

 

 

CONTROLS

1.

Key Switch

9. Vacuum Switch

2.

Emergency Shut Off Switch

10.Squeegee Lift Lever

3.

Speed Control Knob

11.Squeegee Pitch Adjustment Knob

4.

Propel Control Lever

12.Squeegee Deflection Adjustment Knobs

5.

Reverse Button

13.Battery Charge Level Indicator

6.

Brush Switch

14.Parking Brake

7.

Actuator Switch

15.Hour Meter

8.

Solution Control Knob

16.Brush Pressure Indicator

 

 

 

 

1.KEY SWITCH

Controls the power for machine functions. To turn machine on, rotate key clockwise.

To turn machine off, rotate key counterclockwise.

FOR SAFETY: Always remove the key when machine is unattended or during service to prevent unauthorized movement.

2.EMERGENCY SHUT-OFF SWITCH

4.PROPEL CONTROL LEVERS Controls the machine direction, and scrub brushes and solution flow.

To propel machine forward, squeeze either propel lever.

The scrub brushes will not rotate and the solution will not flow to scrub deck with the propel levers in neutral.

5.REVERSE BUTTON Controls the reverse function.

Shuts off machine.

To shut off machine, push the switch.

To restart machine, rotate the switch clockwise.

3.SPEED CONTROL KNOB Controls the speed of the machine.

To increase speed, rotate knob clockwise.

To decrease speed, rotate knob counterclockwise.

To propel machine backward, push the reverse button while squeezing either propel lever.

6.BRUSH SWITCH

Controls the scrub brush motors.

To turn scrub brushes on, press the bottom of the switch. The brushes will not rotate with the propel control levers in neutral.

To turn scrub brushes off, press the top of the switch.

CUTTER 36V (SCEX) 86037040 12/12/06

3-6

Image 13
Contents Models SCEX326 SCEOX326 Walk Behind ScrubberYour Dealer Machine Data LOG/OVERVIEWOverview Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls Emergency SHUT-OFF Switch KEY SwitchBrush Switch Vacuum Switch Solution Control KnobSqueegee Pitch Adjustment Knob Squeegee Lift LeverParking Brake Brush Pressure IndicatorHour Meter Filling Solution Tank Emergency Stop ProceduresMachine Operation PRE-RUN Machine InspectionTo Begin Scrubbing Normal ScrubbingTo Stop Scrubbing Double Scrub Emptying and Cleaning TanksMaintenance Daily Weekly Monthly Maintenance Service ScheduleHRS Maintenance Service Schedule Aintenance Battery Maintenance MaintenanceBatteries Checking Gravity Battery ConditionTo Charge the Batteries Front of Machine Changing BatteriesTo Remove Squeegee Assembly Adjusting SqueegeeSqueegee Blades To Replace or Rotate Rear Squeegee BladesTo Adjust Amount of Rear Squeegee Deflection To Adjust Squeegee PitchTo Replace AQUA-MIZER Squeegee Blades Recovery Tank Float SHUT-OFF Replacing or Installing Scrub BrushesScrub Brushes Uncoated FloorsBrush Motor Carbon Brush Replacement Solution StrainerBrush Motor Changing Brush MotorsTraction Motor Traction Motor Carbon Brush ReplacementCircuit Breakers Brush Shrouds & Brush SkirtsChanging Vacuum Motor Vacuum MotorScrub Deck Actuator Adjustment Actuator Scrub Deck REMOVAL/REPLACEMENTProblem Cause Solution Machine TroubleshootingMachine Troubleshooting