Windsor SCEOX326, SCEX326 To Adjust Squeegee Pitch, To Adjust Amount of Rear Squeegee Deflection

Page 25

TO ADJUST SQUEEGEE PITCH

1.Choose a smooth, level surface. Turn “ON” the key switch. Lower the squeegee and drive forward at least 2 feet (60cm.).

2.With the squeegee down, stop the machine. Do not allow machine to roll back.

FOR SAFETY: Before leaving or servicing the machine; stop on level surface, turn off machine and remove key.

3.Determine the differences, if any, in deflection of the squeegee blade between each end and the middle. Proper adjustment is obtained when deflection is equal all the way across the squeegee blade. The bubble level should also indicate when the squeegee is adjusted properly. When the air bubble is in the center of the vial, the deflection should be even across the squeegee blade.

4.To decrease the deflection of the squeegee blade at the ends, tighten knob near the squeegee center. To increase the deflection at the ends of the squeegee assembly, loosen knob.

5.Check the deflection of the squeegee blades again. Repeat steps 1 through 4 until the deflection is equal across the entire rear squeegee blade.

3/8”

PROPER DEFLECTION OF SQUEEGEE BLADE

MAINTENANCE

TO ADJUST AMOUNT OF REAR SQUEEGEE DEFLECTION

1.Choose a smooth, level surface. Lower the squeegee and drive forward at least 2 feet (60cm).

2.With the squeegee down, stop the machine. Do not allow machine to roll back.

FOR SAFETY: Before leaving or servicing machine; stop on level surface, turn off machine and remove key.

3.Observe the amount of squeegee deflection. It should deflect 3/8 in. (9.5mm) across the entire width of the squeegee.

4.To increase the squeegee deflection, turn the 2 knobs at the squeegee ends counter-clockwise. To decrease the deflection, turn the knobs clockwise.

NOTE: The deflection should be consistent along the length of the squeegee. If the deflection varies from end to end the knobs can be adjusted independently to correct the variation.

5.Turn on the key switch. Raise, then lower squeegee assembly. Drive forward at least 2 feet (60cm).

6.Repeat steps 2 through 4 until deflection of

3/8 in. (9.5mm) is reached.

3.TO REPLACE AQUA-MIZER SQUEEGEE BLADES

These squeegee blades have two wear edges. To use the second edge:

1.Remove deck shrouds.

2.Remove brushes or pad drivers.

3.Remove each of the Aqua-Mizer squeegee systems.

4.Remove the hardware from each system that retains the blade.

5.Flip the blades and replace hardware.

6.Re-install each Aqua-Mizer system, brushes or pad drivers and shrouds.

CUTTER 36V (SCEX) 86037040 12/12/06

4-7

 

Image 25
Contents Models SCEX326 SCEOX326 Walk Behind ScrubberYour Dealer Machine Data LOG/OVERVIEWOverview Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls Emergency SHUT-OFF Switch KEY SwitchBrush Switch Vacuum Switch Solution Control KnobSqueegee Pitch Adjustment Knob Squeegee Lift LeverParking Brake Brush Pressure IndicatorHour Meter Filling Solution Tank Emergency Stop ProceduresMachine Operation PRE-RUN Machine InspectionTo Begin Scrubbing Normal ScrubbingTo Stop Scrubbing Double Scrub Emptying and Cleaning TanksMaintenance Daily Weekly Monthly Maintenance Service ScheduleHRS Maintenance Service Schedule Aintenance Battery Maintenance MaintenanceBatteries Checking Gravity Battery ConditionTo Charge the Batteries Front of Machine Changing BatteriesTo Remove Squeegee Assembly Adjusting SqueegeeSqueegee Blades To Replace or Rotate Rear Squeegee BladesTo Adjust Amount of Rear Squeegee Deflection To Adjust Squeegee PitchTo Replace AQUA-MIZER Squeegee Blades Recovery Tank Float SHUT-OFF Replacing or Installing Scrub BrushesScrub Brushes Uncoated FloorsBrush Motor Carbon Brush Replacement Solution StrainerBrush Motor Changing Brush MotorsTraction Motor Traction Motor Carbon Brush ReplacementCircuit Breakers Brush Shrouds & Brush SkirtsChanging Vacuum Motor Vacuum MotorScrub Deck Actuator Adjustment Actuator Scrub Deck REMOVAL/REPLACEMENTProblem Cause Solution Machine TroubleshootingMachine Troubleshooting