Windsor SCEX326, SCEOX326, 10052340, 10052310 manuel dutilisation Machine Troubleshooting

Page 32

MACHINE TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Little or no solution flow to the floor

Solution tank empty

Fill solution tank

 

Solution flow turned off or

Turn on or increase flow

 

set too low

setting

 

Solution strainer plugged

Clean solution strainer

 

Solution hoses obstructed

Clear obstruction from

 

hose

 

Solution solenoid valve

Clean or replace

 

obstructed or stuck

 

Vent hole in solution tank

Clear obstruction from vent

 

lid obstructed

hole

No power to machine

Battery disconnected

Check all battery cable

connections

 

Emergency shut-off

Reset

 

activated (If included)

 

Battery connections

Clean connections

 

corroded

 

Faulty main contactor

Replace contactor

 

Faulty key switch

Replace switch

Little or no propel

Low battery charge

Charge batteries

 

Wheels spin

Decrease brush pressure

 

 

Allow cool down period

 

 

Adjust brush shroud if

 

Controller overheated

needed

 

 

Check motor wires and

 

Loose connection

connection

4-14

CUTTER 36V (SCEX) 86037040 12/12/06

Image 32
Contents Walk Behind Scrubber Models SCEX326 SCEOX326Overview Machine Data LOG/OVERVIEWYour Dealer Table of Contents HOW to USE this Manual ModelImportant Safety Instructions Read ALL Instructions Before Using this MachineHazard Intensity Level Hazard Intensity LevelSafety Label Location Technical Specifications DIMENSION/CAPACITYSpecial Notes MeasureHOW the Machine Works Components Controls Brush Switch KEY SwitchEmergency SHUT-OFF Switch Solution Control Knob Vacuum SwitchSqueegee Pitch Adjustment Knob Squeegee Lift LeverHour Meter Brush Pressure IndicatorParking Brake Emergency Stop Procedures Filling Solution TankMachine Operation PRE-RUN Machine InspectionTo Stop Scrubbing Normal ScrubbingTo Begin Scrubbing Emptying and Cleaning Tanks Double ScrubHRS Maintenance Service ScheduleMaintenance Daily Weekly Monthly Maintenance Service Schedule Aintenance Batteries MaintenanceBattery Maintenance To Charge the Batteries Battery ConditionChecking Gravity Changing Batteries Front of MachineAdjusting Squeegee To Remove Squeegee AssemblySqueegee Blades To Replace or Rotate Rear Squeegee BladesTo Replace AQUA-MIZER Squeegee Blades To Adjust Squeegee PitchTo Adjust Amount of Rear Squeegee Deflection Replacing or Installing Scrub Brushes Recovery Tank Float SHUT-OFFScrub Brushes Uncoated FloorsSolution Strainer Brush Motor Carbon Brush ReplacementBrush Motor Changing Brush MotorsTraction Motor Carbon Brush Replacement Traction MotorCircuit Breakers Brush Shrouds & Brush SkirtsVacuum Motor Changing Vacuum MotorActuator Scrub Deck REMOVAL/REPLACEMENT Scrub Deck Actuator AdjustmentMachine Troubleshooting Problem Cause SolutionMachine Troubleshooting