Windsor 10052310, SCEX326, SCEOX326, 10052340 Machine Troubleshooting, Problem Cause Solution

Page 31

MACHINE TROUBLESHOOTING

PROBLEM

CAUSE

SOLUTION

Poor or no water pick-up

Squeegee out of

Adjust squeegee

 

 

adjustment

Remove debris

 

Debris caught on squeegee

 

Worn squeegee blades

Rotate or replace squeegee

 

 

blades

 

Vacuum hose clogged

Clear obstruction from hose

 

 

Reconnect vacuum hose

 

Vacuum hose disconnected

 

from squeegee or recovery

 

 

 

 

 

tank

Replace vacuum hose

 

Vacuum hose damaged

 

Recovery tank not sealed

Place recovery tank dome on

 

 

tank. Replace damaged

 

 

gaskets.

 

Foam filling recovery tank

Empty recovery tank

 

 

Use less or different detergent

 

 

Use defoamer

Vacuum motor does not run, or

Recovery tank full

Drain recovery tank

 

runs slowly

 

Clean float system

 

Recovery tank float system

 

dirty

Reset circuit breaker

 

Circuit breaker tripped

 

Loose connection

Check motor wires and

 

 

connections

 

Faulty vacuum switch

Replace switch

 

Worn vacuum motor

Replace brushes, check

 

brushes

commutator

Poor scrubbing performance

Debris caught in scrub

Remove debris

 

 

 

 

brushes

Replace brushes or pads

 

Worn brushes or pads

 

Improper detergent, brush

Contact equipment or

 

or pad used

application specialist

 

Low scrub brush down

Increase brush pressure

 

pressure

Charge batteries

 

Low battery charge

Brush motors do not run, or runs

Circuit breaker(s) tripped

Reset circuit breaker(s)

 

slowly

 

Check motor wires and

 

Loose connection

 

 

connection

 

Faulty brush motor

Replace contactor

 

contactor

Replace brushes, check

 

Worn brush motor brushes

 

 

commutator

CUTTER 36V (SCEX) 86037040 12/12/06

4-13

Image 31
Contents Models SCEX326 SCEOX326 Walk Behind ScrubberYour Dealer Machine Data LOG/OVERVIEWOverview Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls Emergency SHUT-OFF Switch KEY SwitchBrush Switch Squeegee Lift Lever Solution Control KnobVacuum Switch Squeegee Pitch Adjustment KnobParking Brake Brush Pressure IndicatorHour Meter PRE-RUN Machine Inspection Emergency Stop ProceduresFilling Solution Tank Machine OperationTo Begin Scrubbing Normal ScrubbingTo Stop Scrubbing Double Scrub Emptying and Cleaning TanksMaintenance Daily Weekly Monthly Maintenance Service ScheduleHRS Maintenance Service Schedule Aintenance Battery Maintenance MaintenanceBatteries Checking Gravity Battery ConditionTo Charge the Batteries Front of Machine Changing BatteriesTo Replace or Rotate Rear Squeegee Blades Adjusting SqueegeeTo Remove Squeegee Assembly Squeegee BladesTo Adjust Amount of Rear Squeegee Deflection To Adjust Squeegee PitchTo Replace AQUA-MIZER Squeegee Blades Uncoated Floors Replacing or Installing Scrub BrushesRecovery Tank Float SHUT-OFF Scrub BrushesChanging Brush Motors Solution StrainerBrush Motor Carbon Brush Replacement Brush MotorBrush Shrouds & Brush Skirts Traction Motor Carbon Brush ReplacementTraction Motor Circuit BreakersChanging Vacuum Motor Vacuum MotorScrub Deck Actuator Adjustment Actuator Scrub Deck REMOVAL/REPLACEMENTProblem Cause Solution Machine TroubleshootingMachine Troubleshooting