6.SOLUTION STRAINER

The solution strainer is located in front of the left front wheel. The solution strainer protects the solenoid valve from debris. If there is little or no solution flow to the ground, check the strainer for debris. Drain the solution tank and clean the solution strainer. To remove the strainer, turn the bottom part of the strainer counterclockwise until the bottom is separated. Clean out the debris from the wire mesh and re-assemble. Make sure the O- ring gasket is in place when re-assembled

7.BRUSH MOTOR

!

Do not use a pressure washer to clean around the brush motors. Use tap pressure only.

CHANGING BRUSH MOTORS

1.With the scrub deck in the stored position, disconnect brush motor wiring connector from harness.

2.Remove shrouds from scrub deck to access and remove scrub brushes or pad drivers.

3.Remove retaining bolt, lock washer, flat washer and star drive from brush motor shaft.

4.Remove 4 brush motor mounting bolts located under scrub deck.

5.Remove brush motor.

6.Reverse steps to install.

MAINTENANCE

8.Reset end cap and realign with scribe marks on motor barrel. Reinstall the two attach bolts from cap into base.

9.Maintain alignment between motor barrel base and cap.

GREASING AXLE:

1-2 Strokes Mobiltemp®78 or compatible clay-based or calcium-based grease.

NOTE: Use hand operated grease gun only.

BRUSH MOTOR CARBON BRUSH

REPLACEMENT

1.Scribe alignment mark on motor barrel to motor cap. Remove two bolts.

2.Remove end cap from motor.

NOTE: Motors contain two wave washers in cap. Do not lose these.

3.Release brush from spring tension. Remove screw connecting brush wire lead to brush holder. Clean brush holder to insure free movement.

4.Retract spring and install new brush. Install connector screw and lead.

5.When all new brushes are installed. Place all in retracted position, held into brush holder by spring tension.

6.Carefully place end cap onto bearing on motor shaft.

NOTE: Use care to assure wave washer alignment.

7.With end cap in partially installed position, release all brushes to contact position with motor commutator.

NOTE: Failure to insure all brushes are released will result in motor failure.

CUTTER 36V (SCEX) 86037040 12/12/06

4-9

 

Image 27
Contents Models SCEX326 SCEOX326 Walk Behind ScrubberMachine Data LOG/OVERVIEW Your DealerOverview Table of Contents Model HOW to USE this ManualRead ALL Instructions Before Using this Machine Important Safety InstructionsHazard Intensity Level Hazard Intensity LevelSafety Label Location DIMENSION/CAPACITY Technical SpecificationsMeasure Special NotesHOW the Machine Works Components Controls KEY Switch Emergency SHUT-OFF SwitchBrush Switch Squeegee Lift Lever Solution Control KnobVacuum Switch Squeegee Pitch Adjustment KnobBrush Pressure Indicator Parking BrakeHour Meter PRE-RUN Machine Inspection Emergency Stop ProceduresFilling Solution Tank Machine OperationNormal Scrubbing To Begin ScrubbingTo Stop Scrubbing Double Scrub Emptying and Cleaning TanksMaintenance Service Schedule Maintenance Daily Weekly MonthlyHRS Maintenance Service Schedule Aintenance Maintenance Battery MaintenanceBatteries Battery Condition Checking GravityTo Charge the Batteries Front of Machine Changing BatteriesTo Replace or Rotate Rear Squeegee Blades Adjusting SqueegeeTo Remove Squeegee Assembly Squeegee BladesTo Adjust Squeegee Pitch To Adjust Amount of Rear Squeegee DeflectionTo Replace AQUA-MIZER Squeegee Blades Uncoated Floors Replacing or Installing Scrub BrushesRecovery Tank Float SHUT-OFF Scrub BrushesChanging Brush Motors Solution StrainerBrush Motor Carbon Brush Replacement Brush MotorBrush Shrouds & Brush Skirts Traction Motor Carbon Brush ReplacementTraction Motor Circuit BreakersChanging Vacuum Motor Vacuum MotorScrub Deck Actuator Adjustment Actuator Scrub Deck REMOVAL/REPLACEMENTProblem Cause Solution Machine TroubleshootingMachine Troubleshooting