FILLING THE SOLUTION TANK

1.Release dome clamp.

2.Lift upper recovery tank from machine and set aside.

3.Use a clean bucket, recovery tank or hose to fill solution tank with hot water. The solution tank holds 4 gallons (15.2 liters) of cleaning solution.

4.Add a non-foaming concentrate for use in hot water extractors at the proportions noted on the container.

NOTE: Periodically operate the extractor with only hot water to remove chemical residue in carpet.

To avoid possible distortion of the polyethylene solution/recovery tanks, DO NOT USE WATER WITH A TEMPERATURE THAT EXCEEDS 140°F (60°C).

5.Place recovery tank back on machine.

6.Place dome on recovery tank. Make sure dome is seated correctly to ensure proper vacuum seal. Clamp dome securely to recovery tank.

Use only the suitable chemicals listed in the Chemical Section. Using incompatible chemicals will damage the machine. Carefully read ingredients on manufacturer’s label before using any product in this machine.

OPERATION

SPECIAL NOTES:

This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

The sound pressure level at the operator’s ear was measured to be 73.7 dBA. This was a nearfield, broad-band measurement taken in a typical industrial environment on a tile floor. This appliance contains no possible source of impact noise. The instantaneous sound pressure level is below 63 Pa.

The weighted root mean square acceleration at the operator’s arms was measured to be below 2.5m/s2. This was a tri-axial, third-octave-band measurement made during normal operation on a composite tile floor. The measurement and related calculations were made in accordance with ISO 5349-1.

86037780 EXTRACTOR 05/09/08

3-3

Image 11
Contents Mini Carpet Extractor 4 Gallon Overview Machine Data LOG/OVERVIEWTable of Contents HOW to USE this Manual Read ALL Instructions Before Using this Machine SafetyHazard Intensity Level For SafetyVolt Models ElectricalExtension Cords Grounding InstructionsSafety Label Location Chemicals OperationInspection Controls & Components Main Handle Solution ButtonSpecial Notes Operating Instructions Filling the Solution TankOperating the Machine Operating Machine with Accessory ToolsProtect from Freezing MaintenanceDAILY/REGULAR Maintenance Periodic MaintenanceSpray JET Maintenance InstructionsBrush Assembly Pump Removal Brush Motor RemovalVacuum Motor Removal Vacuum Motor Carbon Brushes ReplacementProblem Cause Solution Troubleshooting ChartMaintenance Mini Carpet Extractor Parts List Brush Deck Part PRV no QTY Description Serial no From Control Panel Part PRV QTY Description Serial no From Decal LABEL, Control Panel Frame & Wheels BRKT, Brush HOUSING, 10 Handle Part PRV no QTY Description Solution BOX, Pump Mount Extractor 03/22/07 JET, RT ANG, 1/4 Barb Tank & Dome TANK, SOLUTION, Extractor Vacuum VAC MOTOR, 120V 5.7 3ST W/TUBE 115V only Wiring DIAGRAM-CONTROL Panel Wiring Diagram Control Panel Wiring DIAGRAM-VACUUM, Brush Motor & Pump Wiring Diagram VACUUM, Brush Motor & Pump Ground Micro Screw Switch Conductor Wire ASM, 18GA 4 BLK Dash Line = Pump BOX Outline ASM, Filter EMI Brush Hose Diagram Spare Parts AccessoriesExtractor 12/09/06