Windsor ADM8 10080170 manual Maintenance, Service Schedule

Page 20

MAINTENANCE

SERVICE SCHEDULE

MAINTENANCE

DAILY

WEEKLY

QUARTERLY

Check machine for cord damage

*

 

 

Check recovery dome and gasket for

 

 

 

damage and cleanliness

*

 

 

Check brush – should be clean with no

 

 

 

lint or strings attached

*

 

 

Inspect vac shoe for blockage; remove

 

 

 

fibers with coat hanger, etc.

*

 

 

Check hoses for wear, blockages, or

 

 

 

damage

*

 

 

Check handles, switches, and knobs

 

 

 

for damage

*

 

 

Check vac motor intake filter and clean

*

 

 

Run one gallon of water through

 

 

 

system

*

 

 

Clean out recovery tank and check

 

 

 

float valve to make sure it moves freely

*

 

 

Clean out solution tank and remove

 

 

 

and clean vacuum intake screen

*

 

 

Clean outside of all tanks and check for

 

 

 

damage

*

 

 

Run vac motor for at least one minute

 

 

 

to allow motor to dry

*

 

 

Store with dome off tank to allow the

 

 

 

tank to dry

*

 

 

Check all bearings for noise

 

*

 

Check all gaskets for wear and leakage

 

*

 

Check vacuum intake screen for

 

 

 

damage; replace if necessary

 

*

 

Check pump pressure; observe spray

 

 

 

pattern and check with gauge if

 

 

 

necessary

 

*

 

Check and clean solution screen

 

*

 

Check belts for wear and replace as

 

 

 

necessary

 

*

 

Check brush for wear; ensure bristles

 

 

 

are not damaged

 

*

 

Check cables for fraying

 

*

 

Check the spray bar (manifold) for

 

 

 

damage; replace if broken or bent

 

*

 

Check condition of vac shoe and frame

 

 

 

for damage

 

*

 

Check overall performance of machine

 

*

 

Check vac motor carbon brushes

 

 

*

4-1

ADMIRAL 86038230

Image 20
Contents Carpet Extractor Warranty Registration Machine Data LOG/OVERVIEWTable of Contents HOW to USE this Manual Safety Instructions Read ALL Instructions Before Using this MachineImportantes Mesures DE Sécurité Hazard Intensity Level Hazard Intensity LevelDegrés DE Risques EN CAS DE Danger Degrés DE Risques EN CAS DE DangerGrounding Instructions Proper GroundingThis Product is for Commercial USE only Electrical Technical Specifications Power TypeCONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations Filling Operations StepOperations Adjust handle to comfortable operating OFF Cleaning ProcedureSolution Intake Cover Vacuum Step Step Recovery Drain Solution Accessory Tool Usage Solution Brush Vacuum Inton OFFMaintenance Service SchedulePeriodic Maintenance Daily / Regular MaintenanceVacuum Motor Replacement 38 9.5 mmBelt Replacement Pump Replacement Parts for Flojet 100 PSI Prior to Serial # Wiring Diagram Troubleshooting Chart Problem Cause SolutionAdmiral Frame Assembly PRV no QTY Description Serial no From Open FRAME, CLP FamilyHUBCAP, 5/8 Shaft HARNESS, MAIN, CLP/ADMBrush Assembly HOUSING, Brush LEVER, Height AdjustmentPLATE, Brush Housing RH PLATE, Brush Housing LHPump Assembly CONNECTOR, 1/8FPT X 1/4 Tubeqc PRV no QTY Description Serial no FromCOUPLING, 1/4 Anchor W/1 HEX ELBOW, SWIVEL, 1/4MPTX1/4TUBEVacuum Shoe Assembly COVER, Accessory Port GASKET, Accessory PortPRV no QTY Description ARM, VAC Shoe ParallelControl Panel Assembly BOOT, 3/8 Circuit Breaker SWITCH, Spst 2-POSITION RockerTRIGGER, Switch CLIP, Power CordSolution Tank Assembly HOUSING, VAC Motor ServiceBrush SET, 120V VAC, Windsor Service Only TANK, ADM SolutionRecovery Tank Assembly TANK, ADM Recovery BRKT, Recovery Hose MTGCLAMP, 2.0 Nylon Ratchet TETJER, Drain PlugSuggested Spare Parts