Windsor ADM8 10080170 manual Periodic Maintenance, Daily / Regular Maintenance

Page 21

PERIODIC MAINTENANCE

Twice a month, flush a white vinegar solution (One quart vinegar to two gallons of water) or anti- browning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system. If spray jets become clogged, remove the spray tips, wash them thoroughly, and blow-dry.

NOTE: Do not use pins, wire, etc. to clean nozzles as this could destroy spray pattern.

Periodically inspect all hoses, electrical cables and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation is broken or frayed, repair or replace it immediately. Don’t take chances with electrical fire or shock.

DAILY / REGULAR MAINTENANCE

Before making any adjustments or repairs to the machine, disconnect the power cord from electrical source.

1.Empty unused cleaning solution from the solution tank.

2.Inspect and clean filter screen in solution tank.

3.Flush pumping system with 4 or 7 liters of clean, hot water.

4.After each use, rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a 1-10 bleach to water solution. Waste water should be disposed of properly.

5.Check for and remove any lint or debris around vac shoe.

6.Check spray jets for full spray pattern.

MAINTENANCE

7.Remove lint and dirt build-up from brush and housing.

NOTE: Brush removal.

A.To remove brush, grab and pull brush out from end opposite drive belt (operator’s right). Remove other end from brush driver.

B.To install brush, line up slots in brush core with pin in driver on drive belt side (operator’s left) and push brush onto driver. Then snap bearing end (opposite end) of brush into retaining clip.

8.Check cooling air screen (located on frame behind left wheel) for lint or debris.

9.Check float and shut-off screen and clean as necessary.

NOTE: Always store machine with brush in “Store” position.

ADMIRAL 86038230

4-2

Image 21
Contents Carpet Extractor Machine Data LOG/OVERVIEW Warranty RegistrationTable of Contents HOW to USE this Manual Read ALL Instructions Before Using this Machine Safety InstructionsImportantes Mesures DE Sécurité Hazard Intensity Level Hazard Intensity LevelDegrés DE Risques EN CAS DE Danger Degrés DE Risques EN CAS DE DangerProper Grounding This Product is for Commercial USE only ElectricalGrounding Instructions Power Type Technical SpecificationsCONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations Step Filling OperationsOperations Adjust handle to comfortable operating Cleaning Procedure Solution Intake Cover Vacuum StepOFF Step Recovery Drain Solution Solution Brush Vacuum Inton OFF Accessory Tool UsageService Schedule MaintenanceDaily / Regular Maintenance Periodic Maintenance38 9.5 mm Vacuum Motor ReplacementBelt Replacement Pump Replacement Parts for Flojet 100 PSI Prior to Serial # Wiring Diagram Problem Cause Solution Troubleshooting ChartAdmiral Frame Assembly FRAME, CLP Family PRV no QTY Description Serial no From OpenHUBCAP, 5/8 Shaft HARNESS, MAIN, CLP/ADMBrush Assembly LEVER, Height Adjustment HOUSING, BrushPLATE, Brush Housing RH PLATE, Brush Housing LHPump Assembly PRV no QTY Description Serial no From CONNECTOR, 1/8FPT X 1/4 TubeqcCOUPLING, 1/4 Anchor W/1 HEX ELBOW, SWIVEL, 1/4MPTX1/4TUBEVacuum Shoe Assembly GASKET, Accessory Port COVER, Accessory PortPRV no QTY Description ARM, VAC Shoe ParallelControl Panel Assembly SWITCH, Spst 2-POSITION Rocker BOOT, 3/8 Circuit BreakerTRIGGER, Switch CLIP, Power CordSolution Tank Assembly Service HOUSING, VAC MotorBrush SET, 120V VAC, Windsor Service Only TANK, ADM SolutionRecovery Tank Assembly BRKT, Recovery Hose MTG TANK, ADM RecoveryCLAMP, 2.0 Nylon Ratchet TETJER, Drain PlugSuggested Spare Parts