TROUBLESHOOTING CHART
PROBLEM | CAUSE | SOLUTION | |
No Power, Nothing | Is the cord plugged in. | Plug in cord. | |
Circuit breaker tripped in building. | Reset breaker. | ||
Runs | |||
Faulty switch. | Call for service. | ||
| |||
| Faulty power cord or pigtail. | Call for service. | |
| Vacuum circuit breaker tripped. | Reset breaker. | |
Vacuum Motor Will Not | Faulty main vacuum switch. | Call for service. | |
Run | Loose wiring. | Call for service. | |
| Faulty vac motor. | Call for service. | |
| Carbon brushes worn. | See “Brush Replacement” in | |
|
| maintenance section. | |
| Debris lodged in vac shoe. | Remove debris from vac shoe. | |
Vacuum Motor Runs | Dome gasket defective or missing. | Replace as necessary. | |
But | .Vacuum hose cracked or hose cuff loose. | Replace or repair as necessary. | |
Suction Is Poor | Recovery tank full / float ball stuck in the | Turn off vac motor. Drain and rinse | |
| up position. | recovery tank. | |
| .Main pump switch off. | Turn on. | |
Poor Or No Water Flow | Jets clogged or missing. | Clean using a vinegar /water solution or | |
(Carpet Is Streaky) |
| replace. | |
| Solution filter clogged. | Drain solution tank and clean solution | |
|
| filter. | |
| Faulty solenoid. | Call for service. | |
Brush Does Not Spin | Brush switch off. | Turn on brush switch. | |
Brush circuit breaker tripped. | Reset circuit breaker. | ||
| |||
| Brush belt broken. | Replace as necessary. | |
| Faulty brush motor. | Call for service. |