Windsor ADM8 10080170 manual Pump Replacement Parts for Flojet 100 PSI Prior to Serial #

Page 24

MAINTENANCE

Only qualified maintenance personnel are to perform the following repairs.

Seul le personnel d'entretien qualifié peut effectuer des réparations.

SOLUTION PUMP REPLACEMENT

1.Turn off all switches and unplug the machine.

2.Remove recovery tank.

3.Remove the (2) screws that fasten the solution tank to the frame, and tilt tank back to expose the inside of the frame.

4.Remove solution hoses from fittings in pump.

5.Remove the (2) screws that fasten the pump to the frame.

6.Reverse process to install pump.

86161980 PUMP REPLACEMENT KITS SHURFLO 100 PSI 86026390 PRV NO. (65201) PRV NO. 250-67

Switch Asm

Pump Head Replacement

Bypass Valve Asm

Diaphragm

8251040

86258830

86235100

PRV NO. 65187

PRV NO. 84161

PRV NO. 29206

PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI PRIOR TO SERIAL # *

 

Pump Head

 

Motor

86251090

86247360

PRV NO. 65204

PRV NO. 53245

 

 

Valve Asm

Diaphragm

86258860

86235120

PRV NO. 84166

PRV NO. 29219

4-5

ADMIRAL 86038230

Image 24
Contents Carpet Extractor Warranty Registration Machine Data LOG/OVERVIEWTable of Contents HOW to USE this Manual Safety Instructions Read ALL Instructions Before Using this MachineImportantes Mesures DE Sécurité Hazard Intensity Level Hazard Intensity LevelDegrés DE Risques EN CAS DE Danger Degrés DE Risques EN CAS DE DangerProper Grounding This Product is for Commercial USE only ElectricalGrounding Instructions Technical Specifications Power TypeCONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations CONTROLS/COMPONENT Locations Filling Operations StepOperations Adjust handle to comfortable operating Cleaning Procedure Solution Intake Cover Vacuum StepOFF Step Recovery Drain Solution Accessory Tool Usage Solution Brush Vacuum Inton OFFMaintenance Service SchedulePeriodic Maintenance Daily / Regular MaintenanceVacuum Motor Replacement 38 9.5 mmBelt Replacement Pump Replacement Parts for Flojet 100 PSI Prior to Serial # Wiring Diagram Troubleshooting Chart Problem Cause SolutionAdmiral Frame Assembly PRV no QTY Description Serial no From Open FRAME, CLP FamilyHUBCAP, 5/8 Shaft HARNESS, MAIN, CLP/ADMBrush Assembly HOUSING, Brush LEVER, Height AdjustmentPLATE, Brush Housing RH PLATE, Brush Housing LHPump Assembly CONNECTOR, 1/8FPT X 1/4 Tubeqc PRV no QTY Description Serial no FromCOUPLING, 1/4 Anchor W/1 HEX ELBOW, SWIVEL, 1/4MPTX1/4TUBEVacuum Shoe Assembly COVER, Accessory Port GASKET, Accessory PortPRV no QTY Description ARM, VAC Shoe ParallelControl Panel Assembly BOOT, 3/8 Circuit Breaker SWITCH, Spst 2-POSITION RockerTRIGGER, Switch CLIP, Power CordSolution Tank Assembly HOUSING, VAC Motor ServiceBrush SET, 120V VAC, Windsor Service Only TANK, ADM SolutionRecovery Tank Assembly TANK, ADM Recovery BRKT, Recovery Hose MTGCLAMP, 2.0 Nylon Ratchet TETJER, Drain PlugSuggested Spare Parts