APPLIANCE COMMISSIONING CHECKLIST

Important NOTICE

Explain the operation of the appliance to the end user and hand the completed instructions to them for safe keeping

as the information will be required when making any guaranteed claims.

FLUE CHECK

 

 

Pass

Fail

 

 

 

 

 

 

1.

Flue is correct for appliance

 

 

 

 

 

 

 

 

 

 

2.

Flue flow test

 

 

 

 

 

 

 

 

 

 

3.

Spillage test

 

 

 

 

 

 

 

 

 

GAS CHECK

 

 

 

 

 

 

 

 

 

 

1.

Gas soundness & let by test

 

 

 

 

 

 

 

 

 

 

2.

Standing pressure test

 

 

mb

 

 

 

 

 

 

 

3.

Appliance working pressure (on High Setting)

 

 

mb

 

 

NB All other gas appliances must be operating on full

 

 

 

 

 

 

 

 

 

 

4.

Gas rate

 

 

m3/h

 

5.

Does ventilation meet appliance requirements

 

 

 

 

 

 

 

 

 

 

6.

Have controls been upgraded (Upgradeable models only)

8455 Standard

YES

NO

 

 

 

 

 

 

8456 Programmable Thermostatic and Timer

YES

NO

 

 

 

 

 

 

 

 

 

 

 

 

Retailer AND INSTALLER INFORMATION

Retailer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Purchase. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Model No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Serial No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation Company . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Engineer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Gas Safe Reg No.. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . .

This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco retailer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance Commissioning Checklist is not fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid during the second year, to the extent permitted by law, if the annual service recommended in the Instructions for Use has been completed by a Gas Safe registered engineer, and a copy of the service visit report is available for inspection by a Gazco engineer.

3

Image 3 Contents
Yeoman Exe Midi Contents GAS CHECK APPLIANCE COMMISSIONING CHECKLISTFLUE CHECK Pass FailGeneral User InstructionsLighting the Stove Turning the Stove offUpgrading the Stove Advice on Handling and Disposal of Fire Ceramics Cleaning the stoveFuel bed arrangement User InstructionsheadingHOT Surfaces Installation DetailsInstallation Instructions Technical SpecificationPacking Checklist Location Installation of the gas supplySITE REQUIREMENTS Flue and Chimney RequirementsInstallation of the stove InstallationControl upgrade Safety precautionsFuel BED Arrangement For full instructions see User Instructions, Section Commissioning CommissioningServicing Instructions Servicing RequirementsCheck Flame Failure Functional Check Ignition Functional CheckPilot unit Replacing PartsGeneral Main burnerIgnition lead and piezo PiezoGas valve Main injector Magnetic safety valvePrimary aeration plate Basic Spares List Changing between gas typesSERVICE RECORDS