TROUBLESHOOTING
Problem | Possible Causes | Solutions |
|
|
|
The portable air | ∙ Power failure / outage. | ∙ Restore the power supply. |
conditioner does not | ∙ The automatic switch, line | ∙ Flip the switch / change the fuse / turn the breaker |
turn on | fuse, or breaker has been | back on. Also note that you may have too many |
| tripped. | appliances drawing power on one circuit, you may |
|
| need to move the other appliances to another |
|
| circuit. |
| ∙ The power supply voltage is | ∙ Move the unit onto another circuit with the correct |
| too low. | voltage. |
| ∙ The power cord is damaged. | ∙ Contact Whynter Service Department. Only |
|
| authorized personnel should replace damaged |
|
| power cord or power plug. |
| ∙ The L.C.D.I. power plug for the | ∙ Press the Reset button on the L.C.D.I. power plug. |
| unit is tripped. |
|
| ∙ The internal water reservoir is | ∙ Drain water from the air conditioner. |
| full. |
|
| ∙ Possible loose connection | ∙ Contact Whynter Service Department |
| ∙ Internal fuse has blown |
|
|
|
|
The unit turns on but | ∙ The room temperature is | ∙ This unit is designed to work in ambient |
the compressor does | outside of the operational | temperatures of 64°F to 95°F. |
not turn on (the fan | tolerances of the unit. |
|
runs but the unit is not | ∙ The Cooling mode is not on. | ∙ Press the MODE button until the COOL light is |
cooling) |
| shown on the display. |
| ∙ The compressor has not | ∙ Give the compressor 3 minutes to turn on after the |
| turned on yet because of its | Cooling mode has been selected. |
| time delay. |
|
| ∙ The set temperature is too | ∙ Set the air conditioner to a lower temperature. It is |
| high. | recommended to set the temperature to at least |
|
| 5°F of the ambient temperature. |
| ∙ The internal water reservoir is | ∙ Either manually drain the water by removing the |
| full. | drain plug or allow the unit to exhaust the water |
|
| itself by running the fan only mode. Then cooling |
|
| will resume. |
|
|
|
The air coming out of | ∙ The filters are dirty or | ∙ Clean the air filters. |
the unit is not very | obstructed. |
|
cold, or the airflow | ∙ The air intake or exhaust is | ∙ Make sure there is at least 20" of clearance from |
volume is weak | obstructed. | the air intake. Make the length of the exhaust hose |
|
| is as short as possible. |
| ∙ The unit is set in DRY or FAN | ∙ Set the unit to the cooling mode. |
| mode. |
|
| ∙ The unit is set to low fan | ∙ Set the unit to a higher fan speed. |
| speed. |
|
|
|
|