Whynter ARC-14SH instruction manual Troubleshooting, Problem Possible Causes Solutions

Page 18

TROUBLESHOOTING

Problem

Possible Causes

Solutions

 

 

 

The portable air

Power failure / outage.

Restore the power supply.

conditioner does not

The automatic switch, line

Flip the switch / change the fuse / turn the breaker

turn on

fuse, or breaker has been

back on. Also note that you may have too many

 

tripped.

appliances drawing power on one circuit, you may

 

 

need to move the other appliances to another

 

 

circuit.

 

The power supply voltage is

Move the unit onto another circuit with the correct

 

too low.

voltage.

 

The power cord is damaged.

Contact Whynter Service Department. Only

 

 

authorized personnel should replace damaged

 

 

power cord or power plug.

 

The L.C.D.I. power plug for the

Press the Reset button on the L.C.D.I. power plug.

 

unit is tripped.

 

 

The internal water reservoir is

Drain water from the air conditioner.

 

full.

 

 

Possible loose connection

Contact Whynter Service Department

 

Internal fuse has blown

 

 

 

 

The unit turns on but

The room temperature is

This unit is designed to work in ambient

the compressor does

outside of the operational

temperatures of 64°F to 95°F.

not turn on (the fan

tolerances of the unit.

 

runs but the unit is not

The Cooling mode is not on.

Press the MODE button until the COOL light is

cooling)

 

shown on the display.

 

The compressor has not

Give the compressor 3 minutes to turn on after the

 

turned on yet because of its

Cooling mode has been selected.

 

time delay.

 

 

The set temperature is too

Set the air conditioner to a lower temperature. It is

 

high.

recommended to set the temperature to at least

 

 

5°F of the ambient temperature.

 

The internal water reservoir is

Either manually drain the water by removing the

 

full.

drain plug or allow the unit to exhaust the water

 

 

itself by running the fan only mode. Then cooling

 

 

will resume.

 

 

 

The air coming out of

The filters are dirty or

Clean the air filters.

the unit is not very

obstructed.

 

cold, or the airflow

The air intake or exhaust is

Make sure there is at least 20" of clearance from

volume is weak

obstructed.

the air intake. Make the length of the exhaust hose

 

 

is as short as possible.

 

The unit is set in DRY or FAN

Set the unit to the cooling mode.

 

mode.

 

 

The unit is set to low fan

Set the unit to a higher fan speed.

 

speed.

 

 

 

 

18 P a g e

Image 18
Contents MODEL# ARC-14SH Table of Contents Disposal Safety Precautions Operating Condition DRYHeat Identification of Accessories Image Accessory Name QuantityIdentification of Parts RearOperating Your AIR Conditioner Control PanelInstallation Instructions LocationWindow kit Installation AIR Filters Installation ∙ Before Using Your Portable AIR Conditioner Operation InstructionsHeat Mode Water Drainage Remote Control Installing BatteriesCare and Maintenance Cleaning the PRE-FILTERTechnical Data ARC-14SHTroubleshooting Problem Possible Causes SolutionsA g e ONE Year Limited Warranty Three Year Warranty on Compressor This Warranty does not Cover