Wayne 200000-015 installation manual Typical Sewage Installation, Submersible Sewage Pumps

Page 5

TYPICAL SEWAGE INSTALLATION

1.This installation must be in accordance with the National Electric Code and all applicable local codes and ordinances.

2.Use a basin that is large enough to accommodate the pump. The basin diameter should be a minimum of 18 inches and the depth a minimum of 24 inches.

3.Clean the basin of all debris.

4.Set the pump on a solid, level surface. Do not place pump directly on clay, earth, gravel or sand. A brick or block may be installed under the pump to provide a solid base.

5.Position pump in the basin so the switch is away from incoming water. Verify the float switch has at least 1 in. clearance to the side wall of the basin and is free to move throughout it’s movement.

6.Install discharge plumbing according to local, regional and state codes. Do not reduce the discharge pipe size below that which is provided on the pump.

7.Drill a 1/8 in. “weep” hole in the discharge pipe 1 in. above the pump discharge. Water stream will be visible from this hole when the pump is running. The hole must be cleaned periodically.

8.If optional control device or float is used, follow mounting instruction supplied with device or float.

9.Install a sealed basin cover to prevent debris from falling into the basin, personal injury and contain gases and odors.

10.A union should be installed above the basin to allow easy removal of the pump for cleaning and service.

11.Install a check valve (required) to prevent back-flow. It should be installed above the union.

12.A gate valve or ball valve should be installed above the check valve as required by local, regional or state codes.

13.Connect remaining discharge pipe. The remainder of the discharge line should be as short as possible with a minimum number of turns.

14.A vent pipe is required. It removes gases and odors and should be installed as required by local, regional or state codes.

INSTALLATION MANUAL

15.Secure cords to discharge pipe to prevent possible switch entanglement. Use cable or zip ties to secure the power cords.

16.Connect pump power supply cord to a properly grounded receptacle

17.Fill the basin with water. The pump will start when the water level has reached the switch-on level. Verify the pump is operating normally.

Figure 7: Submersible

Sewage Pumps

1

 

 

 

 

 

11

 

 

 

 

 

2

 

 

 

 

 

10

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

9

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

1.

Check Valve

7.

Switch

2.

Union

8.

Minimum Diameter (18 in.)

3.

Discharge Pipe

9.

Minimum Depth (24 in.)

4.

Inlet Pipe

10.

Gasket/ Basin Lid

5.

Basin

11.

Vent Pipe

6.

Pump

 

 

 

Printed on 100% Recycled Paper

5

Image 5
Contents Safety Guidelines Installation ManualImportant Safety Information DescriptionsTypical Sump Installation Diagrams Installation ManualIT is Recommended to USE Rigid Piping This Pump should be Inspected 3 to 4 Times PERChart a Installation Manual Typical Sump InstallationEffluent Pump in Septic Tank Installation Manual Typical Effluent InstallationSubmersible Sewage Pumps Typical Sewage InstallationTroubleshooting MaintenanceSymptoms Possible Causes Always Disconnect the Pump from Power SupplySymptoms Possible Causes Suggested Remedies Installation Manual Déballage Manuel D’INSTALLATIONDirectives DE Sécurité Information Importante DE SécuritéOn Recommande D’UTILISER UN Clapet DE NON-RETOUR Manuel D’INSTALLATIONDiagrammes D’INSTALLATION DE Pompes DE Puisard Typiques Tableau a Manuel D’INSTALLATION Installation Typique DE PuisardTuyau de sortie de décharge Pompes d’égout submersibles Installation Typique DE Pompe Pour EAU UséeSymptômes Causes possibles Remèdes Suggérés EntretienDépannage Symptômes Causes possibles Dépannage SuiteManuel D’INSTALLATION Descripciones Manual DE InstalaciónDesempaque Guías DE SeguridadSE Recomienda EL USO DE Accesorios Y Tubería Diagramas Típicos DE Instalación DE SumiderosManual DE Instalación Tabla a Manual DE Instalación Instalación Típica DE SumideroInstale la tapa Figura 7 Bombas sumergibles para aguas cloacales Instalación Típica DE Bomba DE Aguas CloacalesMantenimiento Diagnóstico Y Resolución DE ProblemasSíntomas Causas posiblesSíntomas Causas posibles Remedios sugeridos Diagnóstico Y Resolución DE Problemas ContinúaManual DE Instalación Notas

200000-015 specifications

Wayne 200000-015 is a cutting-edge technological advancement in the world of automated systems, specifically designed for enhancing operational efficiency in various industrial sectors. This system stands out due to its advanced capabilities and features that streamline processes while ensuring maximum productivity.

One of the main features of Wayne 200000-015 is its robust processing power. Equipped with a state-of-the-art processor, it can handle complex algorithms and data analysis in real-time, making it ideal for sectors that require immediate decision-making. This speed ensures that users receive timely updates and insights, which can be crucial for maintaining a competitive edge.

A significant technological characteristic of the Wayne 200000-015 is its integration capability. The system is designed to seamlessly integrate with existing platforms, allowing for easy adoption without significant overhauls of current infrastructure. Its compatibility with various software applications ensures that users can utilize the technology in conjunction with their preferred tools, enhancing usability.

Another innovative aspect of the Wayne 200000-015 is its AI-driven analytics. Utilizing machine learning algorithms, the system continuously learns from operation data, providing predictive insights that help businesses forecast trends, optimize processes, and reduce downtime. This feature is particularly beneficial for maintenance scheduling, as it can anticipate potential failures before they occur, thus minimizing disruption to operations.

Security is a top priority with the Wayne 200000-015. It is equipped with advanced security protocols that ensure data integrity and protection against potential cyber threats. An encryption mechanism guards sensitive information while user access controls enable organizations to customize user permissions, ensuring that only authorized personnel have access to critical system functions and data.

Finally, the design of Wayne 200000-015 prioritizes user experience. Its intuitive interface allows users of varying technical skill levels to operate and navigate the system effortlessly. This consideration for user experience drives adoption rates as it reduces the learning curve associated with new technologies, ultimately leading to greater operational efficiency.

In conclusion, the Wayne 200000-015 is an exemplary embodiment of modern technology, combining powerful processing, seamless integration, AI-driven capabilities, robust security, and user-friendly design. Its features position it as an indispensable asset for businesses aiming to enhance their operational efficiency and stay ahead in a competitive landscape.