Admiral AAW-10DR3FHU manual Troubleshooting Guide, Problem Possible Cause Suggested Solution

Page 17

Troubleshooting Guide

Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution.

PROBLEM

POSSIBLE CAUSE

 

SUGGESTED SOLUTION

 

 

 

 

Air conditioner will

No power to the unit.

 

Check connection of power cord to

not operate

 

 

power source.

 

 

 

Check fuse or circuit breaker.

 

 

 

Set FAN CONTROL to position other

 

 

 

than "OFF".

 

 

 

 

Inefficient or no cooling

Dirty air filter.

 

Clean or replace air filter.

 

Inappropriate capacity

 

Check with dealer to determine proper unit

 

for application.

 

capacity for application.

 

Blocked air flow.

 

Remove obstruction from grill or

 

 

 

outdoor louvers.

 

Power interruption, settings

 

Let fan run to restart compressor

 

change too quickly, or

 

(in approximately 10 minutes).

 

compressor overload tripped.

 

 

 

 

 

 

Noisy unit

Loose parts.

 

Tighten loose parts.

 

Inadequate support.

 

Provide additional support to unit.

 

 

 

 

Odors

Formation of mold, mildew, or

 

Remove drain plug and drain base pan.

 

algae on wet surfaces.

 

Replace drain plug.

 

 

 

 

 

 

Clean unit thoroughly.

 

 

 

 

Water dripping outside

Condensation run-off is normal

 

Add flexible tubing to redirect water flow,

 

during hot and humid weather

 

see (Fig.14 Page 10.)

 

 

 

 

Water dripping inside

Unit. is not properly angled to

 

Unit must be installed on an angle for proper

 

allow water to drain outside.

 

condensation run-off. Check the unit and

 

 

 

make adjustments.

 

 

 

 

Ice or frost build-up

Low outside temperature.

 

When outdoor temperature is approximately

 

 

 

65 F or below, frost may form when unit is in

 

 

 

cooling mode. Switch unit to FAN (only)

 

 

 

operation until frost melts.

 

Unit air filter is dirty.

 

Remove and clean filter.

 

 

 

 

NOTE:

If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a licensed technician.

16

Image 17
Contents Room Air Conditioner Table of Contents Part Identification Mechanical control model IntroductionPart Identification Remote control model Electric Shock Hazard Electrical specificationsSee lists below.Fig.A Tips before installationSelect the Best Location Installation instructionsWindow opening requirements Size Model 10K 12K 18-24K Cabinet sizePreparation to Remove Air Conditioner Slide-Out Chassis Assembly of the side shutters curtains to the cabinetTOP View Secure Shutters Installation of the cabinetReinstalling Front Panel Assembly Complete the installation Mode Operating InstructionsElectronic control panel model Buttons How to Use How to Insert the BatteriesCleaning the Air Filter Removal of Air Filter Care and MaintenanceCleaning of Air Filter Air Filter RemovalProblem Possible Cause Suggested Solution Troubleshooting GuideYear Full Warranty WarrantyIdentificaci n de las Piezas Modelo Mec nico Introducci nIdentificaci n de las Piezas Modelo de Remoto controlador Peligro de Descarga El ctrica Especificaciones el ctricasPrecauci N Consejos antes de la instalaci nInstrucciones de Instalaci n Instrucciones de instalaci n Precauci N Instalaci n del gabinete Finalice la instalaci n Precauci N Instrucciones de Operaci nInstrucciones de Operaci n Bot n Mode Modo Control remoto Limpieza del Filtro de Aire Extracci n del Filtro de Aire Cuidado y MantenimientoGu a para la Soluci n de Problemas Garantia Version No