6.Installation of the cabinet

A.Align one hole in the bottom of the cabinet with one hole in the bracket assembly. Secure the cabinet to the bracket using (3) 1/4" screws provided. Repeat the same procedure on the opposite side of the cabinet. See (Fig. 10).

B.Ensure the "L" shaped mounting channel is positioned in front of the sash. The bottom channel of the cabinet should be positioned in the track provided on the bracket assembly. Pull the window down until it rests just behind the front of the "L" shaped mounting channel. See (Fig. 11).

C.Check to make sure that the cabinet is slanted slightly downward on the outside. If necessary, re-adjust support bracket as shown in (Fig. 7).

7.Secure Shutters

A.Carefully slide the air conditioner back into the

cabinet.(Please seek assistance for this procedure).

B.Reinstall the slide-out-chassis security screws (removed earlier) on both sides of the cabinet. See (Fig. 12).

Secure the top of the frames to the window sash with

(2) 3/4" screws.

C. Now, secure bottom frame of shutters using one shutter clamp and one 3/4" screw on each side(Fig. 12).

8.Reinstalling Front Panel Assembly

A.Position the front panel on the cabinet starting at the top. The front panel lock tabs must be inserted into the retaining slots in the cabinet. Repeat this procedure on all sides.

B.Secure the front grille to the cabinet using the Philips screws removed earlier(Fig. 1).

1/4" Screws

Fig. 10

Window Sash

"L"Shaped

Seal

 

Mounting

 

Channel

 

Fig. 11

3/4" screws

 

"L"Shaped

Seal

Mounting

 

Channel

 

Security Screw

Coil

 

Fig. 12

9

Image 10
Contents Room Air Conditioner Table of Contents Introduction Part Identification Mechanical control modelPart Identification Remote control model Electrical specifications Electric Shock HazardTips before installation See lists below.Fig.AWindow opening requirements Installation instructionsSelect the Best Location Size Model 10K 12K 18-24K Cabinet sizeAssembly of the side shutters curtains to the cabinet Preparation to Remove Air Conditioner Slide-Out ChassisTOP View Reinstalling Front Panel Assembly Installation of the cabinetSecure Shutters Complete the installation Operating Instructions ModeElectronic control panel model Buttons How to Insert the Batteries How to UseCleaning of Air Filter Care and MaintenanceCleaning the Air Filter Removal of Air Filter Air Filter RemovalTroubleshooting Guide Problem Possible Cause Suggested SolutionWarranty Year Full WarrantyIntroducci n Identificaci n de las Piezas Modelo Mec nicoIdentificaci n de las Piezas Modelo de Remoto controlador Especificaciones el ctricas Peligro de Descarga El ctricaConsejos antes de la instalaci n Precauci NInstrucciones de Instalaci n Instrucciones de instalaci n Precauci N Instalaci n del gabinete Finalice la instalaci n Instrucciones de Operaci n Precauci NInstrucciones de Operaci n Bot n Mode Modo Control remoto Cuidado y Mantenimiento Limpieza del Filtro de Aire Extracci n del Filtro de AireGu a para la Soluci n de Problemas Garantia Version No