5.Installation of Mounting Brackets and First Sealing Strip

NOTE: Windows come in a variety of different styles. Therefore, it may be necessary to modify or improve your particular installation.

A. Attach the bracket assembly to 90 angle support brackets (Fig. 5) using (2) 1 1/2" bolts

Two bolts per bracket. Secure with the (2) 1/4" lock washers and (2) 1/4"nuts. DO NOT immediately tighten these bolts as it may be necessary to adjust the depth of the bracket assembly, depending on the depth of your window sill. See (Fig. 7).Install the two leveling screws into the

90support brackets. Test the bracket assembly in the window before cabinet installation. If the leveling screws are distanced too far away from the wall to provide stability, it may be necessary for you to fill this area with a solid piece of wood. See (Fig. 8).

B.Measure the inside window sill width and find the center as shown in (Fig. 6). Align the V-slotin each bracket on these marks and mount the brackets to the sill using 3/4" screws provided. Brackets should be perpendicular to the inside window sill. See (Fig. 6).

C.For proper condensation run-off it will be necessary to adjust the angle/pitch of the window brackets. This is accomplished by adjusting the distance of the leveling screw on the outer wall. The maximum angle/pitch should not exceed more than 3/16". See (Fig.7).

D.Cut the seal strip to fit the underside of the bottom

window sash. Remove the peel-off backing on the seal and attach it to this sash. See (Fig. 9).

! CAUTION !

Use a solid piece of wood to provide stability. This will be required when sills are extra deep.

See (Fig. 8).

(TOP VIEW)

 

V-slot

 

Bracket Assembly

 

 

90 Angle

Bracket Bolts

Support Brackets

Leveling Screw

 

Fig. 5

V-slot

Center

9.6" 9.6"

10.3"

10.3"

12.6" 12.6"

Measurement for Model 10K =9.6"

Measurement for Model 12K = 10.3"Window sill Measurement for Model 18K to 24K = 12.6"

Fig. 6

(2) 3/4" screws per bracket

3/16" Maximum

Bracket Assembly

Leveling Screw

Outer Wall Construction

Fig. 7

Solid Piece Wood

(If required)

Fig. 8

Window Sash

Window Sash

Sealing Strip

Fig. 9

8

Image 9
Contents Room Air Conditioner Table of Contents Part Identification Mechanical control model IntroductionPart Identification Remote control model Electric Shock Hazard Electrical specificationsSee lists below.Fig.A Tips before installationSelect the Best Location Installation instructionsWindow opening requirements Size Model 10K 12K 18-24K Cabinet sizePreparation to Remove Air Conditioner Slide-Out Chassis Assembly of the side shutters curtains to the cabinetTOP View Installation of the cabinet Reinstalling Front Panel AssemblySecure Shutters Complete the installation Mode Operating InstructionsElectronic control panel model Buttons How to Use How to Insert the BatteriesCleaning the Air Filter Removal of Air Filter Care and MaintenanceCleaning of Air Filter Air Filter RemovalProblem Possible Cause Suggested Solution Troubleshooting GuideYear Full Warranty WarrantyIdentificaci n de las Piezas Modelo Mec nico Introducci nIdentificaci n de las Piezas Modelo de Remoto controlador Peligro de Descarga El ctrica Especificaciones el ctricasPrecauci N Consejos antes de la instalaci nInstrucciones de Instalaci n Instrucciones de instalaci n Precauci N Instalaci n del gabinete Finalice la instalaci n Precauci N Instrucciones de Operaci nInstrucciones de Operaci n Bot n Mode Modo Control remoto Limpieza del Filtro de Aire Extracci n del Filtro de Aire Cuidado y MantenimientoGu a para la Soluci n de Problemas Garantia Version No