Firex COQ6, COQ3 owner manual How to Install Your CO Alarm

Page 4

!WARNING

This unit cannot be used in recreational vehicle applications.

How to Install Your CO Alarm

!WARNING

ELECTRICAL SHOCK HAZARD. Turn off power at the main fuse box or cir- cuit breaker by removing the fuse or switching the circuit breaker to the OFF position.

!CAUTION

Check local codes for specific mounting requirements in your area.

Once you have decided the best place to install the CO alarm(s), follow these steps:

1.From back of CO alarm, slide mounting plate and lift from base. See Figure 1.

2.For Model COQ6 only: Connect new 9-volt battery to battery connector inside compartment and slide door closed snap- ping it into place. New 9V battery comes from the factory installed backwards inside the battery compartment. Replace battery with Eveready 216, 522, 1222 or equivalent from your local retailer.

3. Align mounting plate with junction box mounting holes.

FIGURE 1

 

4.Gently pull household wires through center hole of mounting plate.

5.Secure mounting plate to junction box.

6.With a small wire connector, connect white wire from the CO alarm to white house- hold wire.

7.Connect black wire from the CO alarm to the black household wire.

8.For interconnecting CO alarms only:

Use #18 AWG minimum solid or stranded wire. When interconnecting, maximum wire length between any two units is 1,500 feet for #18 AWG or 4,000 feet for #14 AWG (20 OHMS loop resistance.) See Figure 2.

WHITE

WHITE

WHITE

 

BLUE

BLUE

TO NEUTRAL

BLACK

BLACK

BLACK

 

 

 

TO 120

VAC (HOT)

FIGURE 2

This CO alarm may be interconnected

with as many as 11 other Firex CO alarms of the same model. DO NOT connect to any other type or model CO alarm or other device.

Connect CO alarms to a single AC branch circuit. If local codes do not permit connection to a single AC branch circuit, be sure the neutral wire is common to all circuits used.

9.Plug wiring harness clip onto pins on the back of the unit.

10.Align tabs on back of base with slots on side of mounting plate. Slide base down to lock into position. See Figure 3.

11.Turn power on at the main fuse box or circuit breaker. The CO alarm will flash the red LED

and emit a short beep during its power-up

FIGURE 3

cycle. The green POWER light will stay on as

 

long as the CO alarm is receiving AC power.

 

4

Image 4
Contents Table Of Contents CO Alarm Features Where to Install Your CO Alarm How to Install Your CO Alarm Service How to Operate Your CO AlarmAlarm Test Your CO Alarm Weekly What to Do if the Alarm SoundsMaintenance and Cleaning Replacing the Battery for Model COQ6 onlySymptoms of Carbon Monoxide Poisoning TroubleshootingConditions That Can Cause CO Levels To Change Home Safety Tips Warranty Information