Bacharach 3015-4256 Functional Overview, General Description, Understanding Monitoring Levels

Page 7

Functional Overview

General Description

Refrigerant monitors are specified to support compliance to federal, state and local safety codes governing refrigerant emissions. Avoiding significant refrigerant loss reduces equipment replacement costs, maintains equipment efficiency, promotes safety, and protects the environment.

The Bacharach HGMSZ (Halogen Gas Monitor Single Zone) is easily programmed to continuously monitor the level of any one of several types of refrigerant gases in an area that is located up to 50 ft (15.2 m) away from the monitor. The HGMSZ displays the type of gas being monitored, along with displaying both the current gas level and the peak gas level detected in that area on its front panel LCD. The monitor retains a log of previous readings that can be easily accessed for analysis.

An audible alarm and front panel indicators are provided to signal alarm and fault conditions, and relay contacts are provided that can be used to trigger external alarm devices in the event of a system fault, or if a leak (small), spill (medium), or evacuation (large) level of gas is detected. The system also includes a 420 mA current loop interface that can be connected to remote monitoring equipment.

The HGMSZ requires only minor periodic maintenance such as the occasional replacement of filters. The monitor incorporates active diagnostics that continuously check the system for proper operation. A front panel indicator is provided to alert an operator of system malfunctions, and fault codes are generated that enable the operator to identify the cause of the fault.

Understanding Monitoring Levels

Effective use of this monitor requires an understanding of what constitutes reasonable alarm set points for the type of gas being monitored. All AC&R systems leak some refrigerant. In a good “tight” installation these background levels will be acceptably low and often do not require corrective action. You can reduce nuisance alarms and needless service calls if the alarm levels are set at practical limits.

Refrigerant manufacturers define allowable exposure levels and threshold limit values in units of parts per million (ppm). Bacharach has developed recommended monitoring levels based on compliance to ANSI/BSR ASHRAE 15-1994 and ASHRAE Safety Code 34-1992. These reference levels are listed in the Appendix (Page 27).

Setting the monitor at these recommended alarm levels will satisfy the needs of most users. However, the ppm levels generated by system leaks into the environment are greatly influenced by the volume of air in the sampling area, air circulation, size of the leak, distance to the monitoring point, and a host of other variables. In some cases the set points may need to be adjusted either up or down to achieve effective monitoring.

Response to the Presence of Multiple Refrigerants

The HGMSZ is a refrigerant level monitor, not a gas analyzer. You must program the monitor to test for a specific refrigerant, and it will only return accurate concentration readings for that particular refrigerant. If a leak occurs of another refrigerant gas type, the monitor may return incorrect readings.

Most applications only require detection of a single refrigerant and the problems that are associated with monitoring multiple gases are rarely an issue. If there is a possibility of multiple refrigerants leaking in the same sampling zone, then you should carefully consider which refrigerant compound you program the unit to monitor.

Instruction 3015-4256

3

Image 7
Contents Hgmsz Halogen Gas Monitor Single Zone Installation / Operation / MaintenanceDeclaration of Conformity Table of Contents Entering Custom Refrigerant Calibration Values Hazard Symbols on Monitor How to Use This ManualSafety Precautions Response to the Presence of Multiple Refrigerants Functional OverviewGeneral Description Understanding Monitoring LevelsSuggested Location of Sampling Point Inspection Installation ConsiderationsLocating the Monitor Mounting Instructions Connecting Gas Sample and Exhaust LinesOverview Connecting the Exhaust Line Connecting the Gas-Sample LineTubing Considerations Interior Schematic Interior SchematicElectrical Wiring Connection Connecting External AlarmsMA Current Loop Interface Typical External Alarm Relay 1 WiringInstruction General Operation Front Panel Display and ControlsDisplay Screens Initial Power UpData Display Screen Function Screens R134A Calfactor Audible Alarm is OFF Working with System Faults Working with Gas AlarmsFault Codes Viewing the Fault LogReset to Factory Default Settings Clearing the Stored PPM Log, Alarms & Faults DataEntering Custom Refrigerant Calibration Values Keypad Functions First Diagnostic ScreenSecond Diagnostic Screen Working with the Diagnos FunctionScreen Display Working with the P-CHK FunctionAdjusting Calibration Factor Calibration ProcedureWorking with the Calibration Function Instruction Servicing Air Lines Clock BatteryCharcoal Filter Hydrophobic FilterReplacement Parts Replacement Parts & Optional AccessoriesOptional Accessories Appendix Table of Recommended Alarm SettingsWarranty Warranty and ServiceRegister Your Warranty by Visiting Service Field Repair Return ProcedureHalon SpecificationsPage Bacharach, Inc Dart Road, Newnan GA Ph 678-423-2481 Fax

3015-4256 specifications

Bacharach 3015-4256 is a highly regarded integrated air quality monitor designed for both commercial and residential applications. This advanced device focuses on detecting and analyzing various air pollutants, ensuring that indoor environments remain healthy and safe for occupants. Its sleek, compact design allows for easy integration into any space, making it an ideal choice for those looking to enhance air quality without compromising aesthetics.

One of the standout features of the Bacharach 3015-4256 is its advanced sensor technology. Equipped with multiple sensors, it can accurately measure levels of carbon dioxide, volatile organic compounds, particulate matter, and humidity. This multi-faceted approach to air quality monitoring ensures comprehensive data collection, allowing users to assess and understand their indoor environment better. The sensors undergo rigorous calibration to maintain accuracy over time, which is critical for effective air quality management.

Another key characteristic of the Bacharach 3015-4256 is its real-time data reporting capabilities. The device continuously monitors air quality levels and provides instant feedback through an easy-to-read display. Users can view real-time updates on air quality metrics, helping them make informed decisions about ventilation and air purification needs. Additionally, the monitor can connect to a mobile app, enabling users to access data remotely, set alerts for specific pollutant levels, and track changes over time.

Safety and user-friendliness are central to the design of this air quality monitor. The device features simple installation guidelines, requiring minimal setup to start monitoring air quality effectively. It also incorporates user-friendly controls, allowing individuals to navigate through settings and features with ease.

Moreover, the Bacharach 3015-4256 is designed with energy efficiency in mind. It operates on low power consumption, making it not only cost-effective but also environmentally friendly.

In summary, the Bacharach 3015-4256 is a sophisticated air quality monitor that offers advanced sensor technology, real-time data reporting, ease of use, and energy-efficient design. Its blend of performance and practicality makes it a valuable tool for anyone committed to maintaining a healthy indoor environment.