1.6.3 MICRO SWITCH

The micro switch assembly, which is located on the barrier of inside unit, automatically shuts off the dehumidifier when the bucket is full (note, the Auto Shut Off lights, to indicate bucket must be emptied). The bucket replaces in its place, the unit again turns itself on.

1.6.4 AUTO DEFROST

When frost builds up on the cooling coils, the compressor will cycle off until the frost disappears. The fan continues to run.

NOTE: This unit is designed to be operated at temperatures above 65°F(18°C). If the dehumidifier is operated in low temperature conditions, the temperature and humidity conditions of room are low, some frost can be formed in its evaporator coil and the unit will be operated ON/OFF repeatedly. In this case, please check on your room temperature condition and stop the unit.

1.6.5 HUMIDISTAT

Humidistat controls constant relative humidity in the room automatically.

When the relative humidity in the room increases to the selected level, the dehumidifier starts automatically. And the relative humidity drops to the selected level, the dehumidifier stops automatically.

When the first using the dehumidifier, it is recommended, for the first three or four days, to operate the unit with the humidistat control set to MAX. At this setting, the unit will run continuously.

When the sweating has stopped and the dampness odors have gone, it is preferable to select the humidistat position that will best suit local conditions.

The relative humidity range it can control is from 20 % to 80%. (See Figure 3)

NOTE: The relative humidity at the number is the approximate value.

42% R.H

5(42%)

 

40%

 

4(50%)

6(35%)

 

3(60%)

 

7(30%)

2(70%)

 

8(25%)

1(80%)

 

9(20%)

 

 

Off

DEAD DIAL

Max.

 

 

Figure 3

1.6.6 DRIER (For some models)

Dryer is used to prevent capillary blockage from moisture in the refrigerant system and H/E, condenser and evaporator. Also, dryer is used to remove corrosion of the components.

NOTE: When dryer is replaced, proper injection to

Dryer

capillary is needed. On opening the dryer, it

should be welded instantly. The oxidization of

 

dryer inside and all tubes inside after welding

 

can be prevented.

 

 

Figure 4

— 6—

Image 6
Contents Dehumidifier Contents Safety Precautions Features Preface DH3010B DH4010B DH5010B SpecificationsModels DHA3012D DHA4012D DHA5012DHOW does the Dehumidifier WORK? HOW to Operate DehumidifierControl Location for the DehumidifierHumidistat Micro SwitchAuto Defrost Capillary is needed. On opening the dryer, itCircuit Diagram Description QTYDH3010B Location Description QTY PER SET MarksMotor RD DH4010B DH5010BBucket and AIR Filter Disassembly InstructionsMechanical Parts Front GrillePower Cord Assy Rotary SWITCH, Humidisat and Neon LampMicro Switch Assy Control PartsFAN and Motor Shroud and BarrierRefrigerating Cycle Rotary Compressor HOW to Replace the Refrigeration System Pulling Vacuum Troubleshooting Guide Possible Causes RemedyCondition Cause Remedy Shuts off the compressor. The fanOr loose, replace the motor. If the motor Exploded View Introduction W0CZZ Model DH4010B/DHA4012DL, DH5010B/DHA5012DLTHERMOSTAT Control Replacement Parts List Location Description RemarkDH3010B/DHA3012DL W0CZZ Capacitor 4995A20085J 4995A20085G 264110 Memo March