Transition Networks SISTP10XX-141-LR(T) installation manual Grounding the Industrial PoE Switch

Models: SISTP10XX-141-LR(T)

1 42
Download 42 pages 54.38 Kb
Page 19
Image 19

SISTP10xx-141-LR(T) Industrial PoE Switch

Transition Networks

Grounding the Industrial PoE Switch

Wiring considerations

CAUTION

Be sure to disconnect the Industrial PoE Switch from the DC power source before installing and wiring the device.

The following wiring considerations are recommended:

Signal lines must not be directly connected to outdoor wiring.

Use separate paths or conduits to route wiring for power and device data cables. To avoid interference, wires with different signal characteristics route separately. If power wiring and device data cables must cross make sure that the wires are perpendicular at the intersection point.

Use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb is wiring that shares similar electrical characteristics can be bundled together.

Keep input and output wiring separated.

 

CAUTION

 

The Industrial PoE Switch is intended to be grounded to a well-grounded mounting

 

surface such as a metal plate. Install the grounding wire prior to connecting any other

 

device to the Industrial PoE Switch.

 

 

Industrial PoE

Grounding the Industrial PoE Switch helps limit the effects of noise due to electromagnetic

Switch

interference (EMI) via proper grounding. Always run the ground connection from the ground

grounding

screw to a grounding surface before connecting the Industrial PoE Switch to a DC power

 

source. See Figure 7.

Figure 7: Industrial PoE Switch Ground Screw (Top Panel)

24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600

11

Page 19
Image 19
Transition Networks SISTP10XX-141-LR(T) installation manual Grounding the Industrial PoE Switch