SISTP10xx-141-LR(T) Industrial PoE Switch

Transition Networks

Connecting an alarm fixture

Alarm relay

The Industrial PoE Switch has dry relay contacts for connecting an external alarm fixture.

 

Located on the green terminal block on the top panel, the relay has “normally open” contacts

 

that can be wired to form a circuit for triggering an external alarm when a fault occurs (light or

 

audible alarm). See Figure 11.

 

Note: Normally open contacts are contacts that form an open circuit when there is a loss of

 

power to the device or when a fault occurs. Once power is applied to the Industrial

 

PoE Switch, the contacts will be closed and current will flow through the contacts.

 

 

Alarm Relay Contacts

 

Figure 11: Alarm Relay Contacts

 

 

 

 

Alarm relay

To wire an alarm to the relay contacts, do the following:

wiring

 

 

 

 

Step

Action

 

 

1.

Verify that the external power source is turned OFF.

 

 

2.

Strip the wires as required.

 

 

3.

Wire the alarm relay as shown in Figure 12.

 

Figure 12: Alarm Relay Wiring

Continued on next page