WARNING
Electrical Shock Hazard
1.Plug unit only into grounded electrical outlet.
2.Do not use an extension cord or plug adaptor with this unit.
3.Do not operate unit with filter removed.
Failure to follow the above precautions could result in electrical shock, fire or personal injury.
If the dehumidifier has a serial plate rating of 115 volts and up to and including 7.5 amps the unit may be on a fuse or circuit breaker with other devices. However, the maximum amps of all devices on that fuse or circuit breaker can not exceed the amps of the fuse or circuit breaker.
Notice
Do not operate this dehumidifier without proper time delay circuit protection. Refer to serial plate for proper power supply requirements.
RECOMMENDED CIRCUIT WIRE SIZES
| (As installed per building code) |
PROTECTOR SIZE | WIRE GAUGE |
15 AMP | #14 MINIMUM |
20 AMP | #12 MINIMUM |
30 AMP | #10 MINIMUM |
115V | 230V | 230V | 230V |
15A | 15A | 20A | 30A |
ELECTRICAL REQUIREMENTS
WARNING
For Your Safety:
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. The fumes can create a fire hazard or explosion.
Power Supply: | 115V, 60HZ |
| AC Only |
Outlet Requirement: | |
Grounding Type: | 125 V, 15 Amp |
Minimum Wire Size: | #14 (A.W.G.) |
| Use Copper Wire Only |
Circuit Protector: | 15 Amp Time Delay Fuse |
| or Circuit Breaker |
Important Grounding Requirements
Your Dehumidifier will operate on any 115 volt,
DO NOT USE AN ADAPTER.
1 |
| Grounded |
| 2 | Single outlet | ||
|
|
|
| grounding | |||
|
|
|
| ||||
wall receptacle |
|
| wall receptacle | ||||
|
|
|
|
|
| ||
grounding plug |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Close Windows and Doors
To assure efficient dehumidification, close all windows and doors in the area where the dehumidifier is to operate (Fig.3).
Plug In
Once you have assembled your dehumidifier and installed it in an appropriate location, plug the cord into a properly grounded outlet as indicated in the electrical requirement (Fig. 4).