Operating the Control Panel continued
LCD Display | The LCD Display will show the room’s relative humidity percentage | |||
| by default. Pressing the | Increase and |
| Decrease buttons |
|
|
will show the set humidity for a few seconds, and then revert to the room’s relative humidity.
Error Codes
In addition to showing the humidity, the display may show the following error codes:
| E1 | – Humidity sensor error | |
| Power the unit off, and then unplug the unit for 15 minutes. Plug in | ||
| and power on. If the issue persists, please contact customer | ||
| service. | ||
| E2 | – Temperature sensor error | |
| Power the unit off, and then unplug the unit for 15 minutes. Plug in | ||
| and power on. If the issue persists, please contact customer | ||
| service. | ||
| P1 | – Unit is defrosting | |
| Allow the unit time to defrost. The error will clear itself after the unit | ||
| has been defrosted. | ||
| P2 | – Bucket is full | |
| Empty the water bucket and reinstall it. | ||
|
|
| |
Water Full Light | The Water Full Light will illuminate when the bucket is ready to be | ||
| emptied. The light also turns on when the bucket is not installed or | ||
| installed incorrectly. Once the water is drained, and the bucket is | ||
| properly installed, the unit will operate normally. | ||
|
|
| |
| Additional notes about the dehumidifier’s behavior: | ||
| ∙ | Once the unit reaches the desired set humidity, the power | |
|
| button will remain lit while the compressor and fan shuts off. | |
| ∙ | You will not be able to change the fan speed. | |
| If the power to the unit was interrupted while the compressor | ||
|
| was running, the unit may take a few minutes to start the fan | |
| ∙ | and compressor. | |
| If the room’s relative humidity is lower than the set humidity, the | ||
|
| unit will not start the fan and compressor unless you set the unit | |
|
| to run in Continuous mode. |
EdgeStar Portable Dehumidifier | 6 |