Beckett CF 2300A Mount the burner, Mount flanges on air tube, Mount air tube to burner

Page 6

Instruction Manual – Model CF2300A Oil Burner

Mount the burner

Mount flange(s) on air tube

This section does not apply to burners with welded flanges.

Do not install air tube on burner.

For non-pressure firing flange, refer to Figure 3: Install gasket (item a) and flange (item d). Ignore the next paragraph.

For pressure-firing flange, refer to Figure 3: Slide gasket (item a) onto the air tube, making sure the top of the air tube is up. Predrill holes in the pressure firing plate (item b) to match the appliance studs. Slide the pressure firing plate (item b) and flange (item d) onto the air tube as shown. Wrap ceramic fiber rope (item c) around the air tube and press tightly into the inside diameter of the flange (item d).

Slide the air tube (item e) into position in the appliance front. Tighten the flange-mounting-stud nuts. Set the insertion of the air tube so dimension G is ¼" nominal.

Pitch the air tube at 2° from horizontal as shown and secure the flange to the air tube. Remove the flange-mounting stud nuts and remove the air tube from the appliance.

Figure 3 – Mount flange(s) on air tube

G

Figure 4 – Nozzle and nozzle line assembly

S Q

P

R

2306-1

 

 

 

2306-2

Critical dimensions —

 

 

S (Electrode spacing) =

³⁄₃₂"

P (Nozzle center line to electrode tip) = ¹⁄₄"

Q (Nozzle to head) =

¹⁄₄"

R (Nozzle face to electrode tip)

= ¹⁄₈"

c

e

Failure to properly set and maintain the electrode and nozzle spacing dimensions can cause incorrect burner ignition or poor combustion. This could result in severe personal injury, death or substantial property damage.

a b d

2312

Mount air tube to burner

Remove the rear access door from the back of the burner for improved access to the interior.

Attach the air tube to the burner with the bolts and acorn nuts provided. The acorn nuts must go on the outside of the burner, with the bolts inserted from the inside.

Install nozzle

See Figure 4. Install the oil nozzle in the nozzle adapter. Use a ³⁄₄" open-end wrench to steady the nozzle adapter and a ⁵⁄₈" open-end wrench to turn the nozzle. Tighten securely but do not overtighten.

Check, and adjust if necessary, the critical dimensions P, Q, R and S shown in the drawing. Verify that the oil tube assembly and electrodes are in good condition, with no cracks or damage.

Install nozzle line assembly

Insert the nozzle line assembly into the burner air tube as in Figure 5.

See Figures 5 and 6. Assemble the adjusting plate assem- bly per the instructions in the assembly packet.

Slide the secondary adjusting plate (item f) completely to the left on the indicator adjusting plate (item e). Finger- tighten acorn nut c to secure the two plates together. Slide both plates completely to the left on the primary adjusting plate (item g) and finger-tighten acorn nut d.

Slide the completed adjusting plate assembly over the nozzle line end. Move the plate assembly and the nozzle line so the plate assembly fits into position as shown in

Figure 5.

Install the spline nut ( Figure 5, item b) on the end of the nozzle line, leaving the nut loosely placed so the plates can be moved.

Connect the high-voltage leads from the ignition trans- former to the electrodes.

6

Form 6104 BCF-23-R0399

Image 6
Contents Low/High Operation Firing rate 7.0 19.9 GPHHazard definitions To the installerPlease . . . read this page first To the ownerContents Before you beginPre-installation checklist Verify firing rate Verify air tubeAir tube capacity vs. firebox pressure Mount the burner Install nozzleInstall nozzle line assembly Mount flanges on air tubeSet dimension Z Insert burnerOne-pipe oil system by-pass loop Connect fuel linesFuel unit by-pass plug Oil supply/return linesBurner fuel flow Fuel unit gearset capacitiesFuel unit Gearset capacity Model number Gallons per hour Wire the burner 120v/60 hzElectrical shock hazard can Sequence of operation typical Prepare the burner for start-upInitial air settings Figure DimensionAdjusting plate assembly Figure Initial head position FigureInitial air adjusting plate settings Damper position Adjusting plate Tube KG Tube KS SettingsApproximate Firing rate, gph Start the burner Start burner and vent air from oil lineSet high-fire air Monthly maintenance Maintenance and serviceAnnual service Set low-fire airReplacement parts Adjustable mounting plates for CF2300A

CF 2300A specifications

The Beckett CF 2300A is a highly regarded oil burner designed for residential and light commercial use. Known for its reliability and efficient performance, the CF 2300A is a favored choice among HVAC professionals and homeowners alike. This model optimizes fuel efficiency while ensuring a consistent and dependable heat output, making it suitable for various heating applications.

One of the standout features of the Beckett CF 2300A is its advanced combustion technology. Equipped with a unique air-to-fuel ratio control system, this burner optimizes the mix of air and fuel, resulting in cleaner combustion and increased energy savings. This technology not only enhances heating efficiency but also reduces the environmental impact by minimizing harmful emissions.

The CF 2300A is designed with a sleek, compact profile that allows for easy installation in tight spaces. Its versatile mounting options and adjustable dimensions accommodate various installation configurations, making it a flexible choice for both new and retrofitting projects. Additionally, the burner is compatible with a wide range of fuel types, including traditional heating oil, which enhances its usability across different heating systems.

Built for durability, the Beckett CF 2300A features robust components that withstand the rigors of daily operation. Its heavy-duty construction ensures longevity, reducing the need for frequent replacements or repairs. Furthermore, it includes a reliable ignition system that provides quick starts and consistent operation, making it a dependable choice for homeowners.

Another key characteristic of the CF 2300A is its low noise operation. The design incorporates noise-reducing technologies that minimize the sound output during operation, contributing to a comfortable indoor environment. This feature is particularly beneficial in residential settings where quiet heating solutions are desired.

In conclusion, the Beckett CF 2300A oil burner combines innovative technologies with reliable performance characteristics. Its advanced combustion system, flexible installation options, robust construction, and quiet operation make it an optimal choice for residential and light commercial heating needs. With a focus on efficiency and longevity, the CF 2300A continues to set a standard in the industry, providing dependable heat while prioritizing environmental sustainability.