Beckett CG10 manual Replacement Parts, See Table

Page 28

Section: Replacement Parts

Replacement Parts

For best performance specify genuine Beckett replacement parts.

1

2

3

6

7

 

 

 

 

 

 

4

5

17

 

 

 

 

16

 

 

 

14

15

 

 

 

13

17

 

 

12

17

 

 

 

 

 

 

11

 

 

 

 

 

 

19

 

 

10

 

18

8

9

 

20

 

 

 

 

Item

Description

Part #

1

Ignition Transformer

7503U

2

Control Subbase

See Note 1

3

Primary Control

See Note 1

4

Suction Line

32359U

5

Shutter

3215U

6

High Gas Pressure Switch

2190903U

7

Air Band

3819A

8

Motor - 120v

21341U

 

- 220v

21654U

9

Blower Wheel - CG10

21448U

 

- CG10A or CG10B

21339U

10

Air Proving Switch

32359U

11

Electrode Set

Spec. Applic.

12

Spring Clamps (4 in pckg.)

3236501U

Item

Description

Part #

13

Head

Spec. Applic.

14

Cable, Ignition Electrode

5990130U

15

O-ring set (2 in package)

32264U

16

Gas Tube assembly

5193201U

17

Jacking Screw

5193401U

18

Air Tube

Spec. Applic.

19

Cable, Flame Rod (if used)

5990280U

20

Flame Rod (if used)

2191301U

 

UV Scanner (not shown)

7247U

21

Restrictor O-Ring (LP Only)

3226409U

22

Propane Restrictor (LP Only)

See Table 3

Note 1: Refer to the UL Label for controller model number.

28

Image 28
Contents Fire, Explosion and Asphyxiation Hazards Contents General Information Hazard DefinitionsOwner’s Responsibility Follow these instructions exactly To the OwnerExactly Special Requirements When contacting Beckett forAgency Approvals Pre-installation Checklist Indoor Installation Protect against Dust MoistureTest For Gas Pipe Leaks ClearancesVerify firing input range Fuel gas supplyVerify burner air tube assembly MBHBurner Dimensions Burner Model Airtube Dim. a Dim. BMount the Burner Connect Gas PipingProtect the Air Tube from Overheating Do Not Use Teflon Tape on Gas PipingInstall a Drip Leg in Gas Supply Piping Gas Trains Gas Leaks and Exposion HazardsGas supply piping capacity Pipe Length ftUL gas train configuration Wire the Burner Keep Service Access Covers Securely InstalledDo Not Bypass Safety Controls Electrical Shock HazardProfessional Installation Service Required Delayed Ignition, Explosion Fire HazardsSequence of Operation Prepare the Burner for Start-upGeneral Gas Supply PipingElectrical Boiler or ApplianceCG10 component familiarization Major Components Item DescriptionStart the Burner Burner start procedureVerify input firing rate Initial burner settings Shutter and BandTemperature correction Estimating RateClocking a gas meter Uncorrected flow rateCG10.6S CG10.5S CG10.4S CG10.3S CG10.2S CG10.1S Flame safeguard safety lockout Simulate a Use test instruments to set combustion Recommended combustion test sequenceMaintenance and Service Annual Professional Service RequiredAnnual maintenance Turn Off Electric and Gas Supply Before ServicingAdjust the burner for proper combustion Flame safeguardInstallation area Ignition Reliability Manual shutdown for long periodsGas Gun Assembly Installation Propane Restrictor DescriptionReplacement Part Numbers Propane RestrictorsPeriodic Inspection Sheet Inspect Heating System RegularlyTest/Inspection Frequency Comments Replacement Parts See TableLow Rate Burner Configuration 300 to 800 MBH Applications Burner ConfigurationsHigh Rate Burner Configuration 600 to 1200 MBH Applications Gas Gun Nominal Assembly Capacity, MBH Air Platform Blower Wheel Air InletBurner Model ShroudCG10 Burner Manual Limited Warranty Information
Related manuals
Manual 2 pages 33.71 Kb

CG10 specifications

The Beckett CG10 is a premium gas furnace that stands out in today's competitive heating market due to its innovative technology and reliable performance. Designed with efficiency and comfort in mind, the CG10 model ensures optimal heating solutions for residential spaces.

One of the most significant features of the Beckett CG10 is its impressive Annual Fuel Utilization Efficiency (AFUE) rating. With ratings often exceeding 90%, this furnace significantly reduces energy consumption and ensures cost-effective heating. This high-efficiency rating translates to lower utility bills and less environmental impact, making it a smart choice for eco-conscious homeowners.

The CG10 utilizes advanced combustion technology to ensure that fuel is burned effectively, maximizing heat generation while minimizing emissions. This innovative technology not only enhances the furnace's performance but also contributes to cleaner air, aligning with modern environmental standards.

A notable characteristic of the Beckett CG10 is its quiet operation. The unit is designed to operate with minimal noise, ensuring a comfortable living environment without disruptive sounds. This is particularly important for families and individuals who prioritize tranquility in their homes.

The furnace is built with durable materials, ensuring longevity and reliable performance over the years. Its construction adheres to strict industry standards, making the CG10 both robust and dependable. Regular maintenance is simplified thanks to its user-friendly design, which allows homeowners to access critical components easily.

Safety is a paramount concern in any heating system, and the Beckett CG10 does not disappoint. It comes equipped with multiple safety features, including flame sensors and safety shut-off mechanisms, ensuring peace of mind for users.

Additionally, the Beckett CG10 can be integrated with smart home technology, allowing homeowners to monitor and control their heating system remotely. This capability enhances convenience and provides further energy savings, as users can adjust their heating preferences from anywhere.

In summary, the Beckett CG10 gas furnace presents an ideal solution for homeowners seeking a blend of efficiency, durability, and advanced technology in their heating systems. Its high AFUE rating, quiet operation, and safety features make it a top choice for those prioritizing comfort and environmental responsibility.